A-3 D A B C 3
A-3 D
4000 1800 4000
4000 1800 4000
UP 1000
6 6
D-2
4
D-2
ROOM 2 3000
4
A-3
4 ROOM 5 W-1 3000
4
A-3
1800 D-2
1800 D-2
KITCHEN
3 10200
3 D-2 10200
LANDING
UP LANDING W-1
2400 ROOM 6 2400
2400 W-1 2400
DN
2 2
D-2
D-2
LIVING ROOM 3000 BALCONY 3000
W-1 LIVING ROOM 2
3000 ROOM 1 3000
1
D-1
W-1
1 W-1 W-1
W-2
5800 4000
5800 4000
9800
9800
FGL FGL
1 2 3 4 5 6
0.40mm THK. PRE-PAINTED 0.40mm THK. PRE-PAINTED 10200
10200
LONGSPAN RIDGE ROLL LONGSPAN RIDGE ROLL
3000 2400 1800 3000 3000 1800 2400 3000
APEX LINE OF ROOF APEX LINE OF ROOF
0.50mm THK. PRE-PAINTED 0.50mm THK. PRE-PAINTED
FLASHING FLASHING
2322 0.40mm (metal base thickness) WITH 0.40mm (metal base thickness) WITH
2900 2900
TOTAL SHEET THICKNESS WITH TOTAL SHEET THICKNESS WITH 2322
CORRUGATED GALVANIZED IRON CORRUGATED GALVANIZED IRON
TOP OF ROOF BEAM ROOFING SHEETS ROOFING SHEETS TOP OF ROOF BEAM
FGL FGL
2400 3000 1800 3000 1800 2400 3000
10200 10200
4 4 FLASHING
2400 2400
2 2
3000 3000
1 1
1675
A B C D A B C D
10200 9800
APEX LINE OF ROOF 4000 2200 4000 4000 1800 4000
0.4mm THK
PRE-PAINTED LONGSPAN
CORR. GI ROOFING SHEET
2900 SEE TRUSS DETAIL
SEE TRUSS DETAIL
W.C. BALCONY
3200
W-1 W-1
W-1 ROOM 4 ROOM 5
SECOND FLOOR LEVEL ROOM 5
W.C.
3200
W-1
1 1 W-1
1 1 W-1
1
ROOM 2
FFL ROOM 2 ROOM 1
FGL
5800 4000
3000 1800 2400 3000
9800
10200
1200 1200
1000 1000
KD & TERMITE-TREATED PANEL DOOR HOLLOW CORE FLUSH TYPE SWING DOOR HOLLOW CORE FLUSH TYPE SWING DOOR CONC. JAMB WINDOW W/ CLEAR CONC. JAMB WINDOW W/ CLEAR CONC. JAMB WINDOW W/ CLEAR GLASS
TYPE HINGED DOOR & FIXED GLASS & FIXED GLASS TRANSOM IN 50mmX150mm ON 50X100mm CONCRETE JAMB w/ GLASS BLADES AND WITH FIXED GLASS BLADES AND WITH FIXEED BLADES AND WITH FIXED CLEAR GLASS
TRANSOM IN 50mmX150mm WOOD WOOD JAMB WITH MARINE PLYWOOD (TWO MARINE PLYWOOD FACING INSIDE AND CLEAR GLASS TRANSOM CLEAR GLASS TRANSOM TRANSOM
JAMB/FRAME AND LEVER-TYPE KNOB FACE) WITH HARDWARE & ACCESSORIES ORDINARY OUTSIDE COMPLETE w/
AND CYLINDRICAL DOOR KNOB HARDWARE AND ACCESSORIES @ FRONT ELEV. @ FRONT ELEV. @ REAR ELEV.
@ FRONT ELEV.
@ EVERY FRONT ELEV. & EXIT @ TOILET 10 SETS 2 SETS
D 50 mm Ø G.I. PIPE
SCHEDULE 40
D LANDING
LANDING 50 mm Ø G.I. PIPE
(PAINT FINISH) SCHEDULE 40
1300
1300
(PAINT FINISH)
10 10
11 9 11 9
12 8 12 8
1 DETAIL PLAN OF STAIR 2 DETAIL PLAN OF STAIR 50 mm Ø G.I. PIPE 300 300 300
100 100 100
3200
9
8
7
900
168
6
5
1520
LANDING 4
3
2
1
50
50
350
50 1200 2800
300
CONF. REINF.
JOINT HOOP SPACE @"2Sh" WHEN
GENERAL NOTES NOTES ON CONCRETE MIXES & PLACING 3. IF SLABS ARE REINFORCED BOTHWAYS BARS ALONG THE SHORTER SPAN SHALL BE PLACED
THERE ARE BEAMS HAVING WIDTH OF
BELOW THOSE ALONE THE LONG SPAN AT THE CENTER AND OVER THE LONGER SPAN FOR
D JOINT REINF. D
REINFORCING BARS NEAR THE SUPPORTS, THE SPACING OF THE BARS AT THE COLUMN STRIPS AT LEAST ONE-HALF THE COLUMN
1.0 STANDARDS AND REFERENCES 1. ALL CONCRETE SHALL DEVELOP A MIN. COMPRESSIVE STRENGTH AT THE END OF TWENTY EIGHT
WIDTH & DEPTHS NOT LESS THAN
THE FOLLOWING SHALL GOVERN THE DESIGN FABRICATION AND CONSTRUCTION OF THE (28) DAYS W/ CORRESPONDING MAXIMUM SIZE AGGREGATE & SLUMP AS FOLLOWS. SHALL NOT BE MORE THAN ONE AND A HALF (1) SLAB THICKNESS.
THREE QUARTERS OF THE DEEPEST
PROJECT.
4. TEMPERATURE BARS FOR SLAB SHALL BE GENERALLY PLACED NEAR THE FACE IN THE TENSION BEAM THAT FRAME INTO FOUR
CONF. REINF.
1.1 NATIONAL STRUCTURAL CODE OF THE PHILIPPINES (N.S.C.P 2015) VOL 1, LOCATION 28 DAYS STRENGTH MAX. SIZE OF MAX SLUMP
AGGREGATE AND SHALL NOT BE LESS THAT 0.0025 X GROSS-SECTIONAL AREA (Ag) OF THE SLAB. (SEE SIDES OF THE COLUMN, ALL OTHER
SEVENTH EDITION CONDITIONS USE HOOP @ "Sh" CENTERS
SCHEDULE BELOW)
2.0 DESIGN CRITERIA
8h
2.1 LOADINGS ALL OTHERS, INCLUDING 3000 PSI (20.7 MPa) 20mm 100mm
A. DEAD LOAD SUSPENDED SLABS
COLUMN TIES AS
SCHEDULE OF MINIMUM SLAB REINFORECEMENT
PER SCHEDULE
CONCRETE 23.56kN/m³ COLUMNS 3000 PSI (20.7 MPa) 20mm 100mm
STEEL 76.93kN/m³ BEAMS, SLABS 3000 PSI (20.7 MPa) 20mm 100mm FOR COL. BAR SPLICES SEE TABLE
MINIMUM TEMPERATURE BARS
150 mm THK. CHB WALL 2.73 kPa SLAB ON FILL 2500 PSI (17.5 MPa) 20mm 100mm OF MIN. LAP SPLICE LENGTH OF
150 mm THK. CHB WALL 2.11 kPa 100mm 10mm Ø @250mm EACH WAY COLUMN REINFORCEMENT
B. LIVE LOAD 2. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS.
125mm 10mm Ø @250mm EACH WAY
CONF. REINF.
ROOF 1.00 kPa SUSPENDED SLABS ------------------------------------------------------------------------------------------- 20mm
CLASSROOMS 1.90 kPa SLAB ON GRADE --------------------------------------------------------------------------------------------------- 40mm 150mm 10mm Ø @250mm EACH WAY
8h
D JOINT REINF. D
TOILETS 1.90 kPa WALLS ABOVE THE GRADE ---------------------------------------------------------------------------------- 25mm
CORRIDORS ABOVE, STAIRS 3.80 kPa BEAMS STIRRUPS AND COLUMN TIES ----------------------------------------------------------------- 40mm 175mm 10mm Ø @250mm EACH WAY NOTE:
CORRIDORS ON GROUND 4.80 kPa WHERE CONCRETE IS EXPOSED TO ALL CONCRETE REINF. DETAIL SHOULD
200mm 10mm Ø @250mm EACH WAY
C. WIND LOAD EARTH BUT POURED AGAINST FORMS ----------------------------------------------------------------- 50mm BE DONE IN ACCORDANCE WITH ACI
BUILDING CATEGORY = 1 (ESSENTIAL FACILITIES) DETAILING MANUAL (LATEST EDITION)
WHERE CONCRETE IS DEPOSITED
CONF. REINF.
EXPOSURE = D (FLAT, UNOBSTRUCTED AREAS AND WATER SURFACES)
DIRECTLY AGAINST EARTH ---------------------------------------------------------------------------------- 75mm 5. UNLESS OTHERWISE NOTED IN THE PLANS ALL BEDDED SLABS SHALL BE REINFORCED WITH 10mm
MAXIMUM WIND VELOCITY, V=340KPH
3. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION RE-HANDLING OR Ø AT 250mm O.C. EACH WAY TO CENTER OF SLAB AND CONTRACTION JOINTS FOR THE SAME
P=qh [(GCpf)-(GCpi)] (DESIGN WIND PRESSURE) PLACING SHALL BE DONE PREFERABLY WITH BUGGIES, BUCKETS OR WHEELBARROWS, NO CHUTES SHALL NOT BE LESS THAN 3.65 METER APART.
WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS TO BUGGIES, 6. PROVIDE EXTRA REINFORCEMENTS FOR CORNER SLAB (TWO ADJACENT DISCONTINUES EDGES)
WHERE: qh=VELOCITY PRESSURE (kPa) WHEELBARROWS OR BUCKETS IN WHICH CASE THEY SHALL NOT EXCEED SIX (6) METERS IN AS SHOWN BELOW.
GCpf=EXTERNAL PRESSURE COEFFICIENT AGGREGATE LENGTH. TYPICAL COLUMN ELEV. SHOWING
GCpi=INTERNAL PRESSURE COEFFICIENT 4. NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS UNLESS 7. CONCRETE SLAB REINFORCEMENT BE PROPERLY SUPPORTED WITH 10mm STEEL CHAIR PR
AUTHORIZED IN WRITING DESIGNER AND ONLY FOR UNUSUAL CONDITIONS WHERE VIBRATIONS APPROVED EQUIVALENT SPACED AT 1.0 METER ON CENTER BOTHWAYS. DOWELS AND TIES SPACING
D. SEISMIC LOAD ARE EXTREMELY DIFFICULT TO ACCOMPLISH.
5. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS SHALL BE PROPERLY POSITIONED & SECURED 12Øx1000 LONG AT SAP SPLICE LENGTH:
MID-DEPTH OF SLAB AT ANY LEVEL NO MORE THAN
V= Cvl
RT W (DESIGN BASE SHEAR) IN PLACE PRIOR TO PLACING OF CONCRETE. ALTERNATE BARS SHOULD BE
6. ALL CONCRETE SHALL BE KEPT FOR A MINIMUM OF SEVEN CONSECUTIVE DAYS IMMEDIATELY DOWN INTO EDGE BEAM EXTENDED SPLICED. MIN. DISTANCE BET.
4-12Ø @ 1800 LONG TOP BARS BEND AT EACH CORNER
Vmax = 2.50Cal
RT W Vmin = 0.11CalW AFTER POURING BY THE USE Of WET BURLAP, FOG SPRAYING, CURING COMPOUNDS OR OTHER BARS MIN. OF 1,200 (4'0") INTO BARS 1-12Ø TOP &
TWO ADJACENT BARS SPLICES
400
L
WHERE: W = TOTAL DEAD LOAD FOUNDATION ---------------------------------------------------------------------------------------------------------- 24 HRS
WITHIN CENTER
T = NATURAL PERIOD = Ct(h)
0
SUSPENDED SLAB EXCEPT WHEN -------------------------------------------------------------------------------- 8 DAYS SLAB
60
38mm
HALF OF "H"
OPENING CLEAR
WHERE: C = NUMERICAL COEFFICIENT ADDITIONAL LOADS ARE IMPOSED
0
60
0.25L
h = BUILDING HEIGHT WALLS ------------------------------------------------------------------------------------------------------------------ 21 DAYS
400
I = IMPORTANCE FACTOR = 1.50 TOP BARS @ SUPPORT (CONT.)
BEAMS ------------------------------------------------------------------------------------------------------------------ 14 DAYS
R = NUMERICAL FACTOR = 8.50 REQ'D BOTT. BARS @ SUPPORT
COLUMNS ------------------------------------------------------------------------------------------------------------------ 21 DAYS IN TWO WAY SLAB EXTEND
SEISMIC COEFFICIENT Cv = 0.44Nv
JT. REINF.
8. THE CONTRACTOR SHALL SUBMIT THE SCHEDULE OF POURING THE LOCATION OF THE BARS UP TO BEAM SUPPORT
60
Ca=0.64Nv
0
CONSTRUCTION JOINTS TO THE STRUCTURAL ENGINEER AT LEAST (4) DAYS PRIOR TO THE OMIT TRIMMER BARS WHERE
NEAR SOURCE FACTOR (5 km) Nv = 1.5 OPENING IS FRAMED BY BEAM
Na = 1.2 POURING FOR APPROVAL. TYPICAL CORNER SLAB DETAIL
Z = SEISMIC ZONE = 0.40 (ZONE4) 9. THE CONTRACTOR SHALL FURNISH AND MAINTAIN ADEQUATE FORMS AND SHORINGS UNTIL THE TYPICAL SLAB
BOTTOM BARS
S = SOIL TYPE = D CONCRETE MEMBERS HAVE ATTAINED THEIR WORKING CONDITION AND STRENGTH. OPENING DET. 0.185L SPLICE AT MIDSPAN
2.2 DESIGN STRESSES NOTES ON FOOTINGS NOTES ON COLUMNS 0.22L EXTRA TOP BARS
@ SUPPORT
1. FOOTINGS ARE DESIGNED FOR AN ALLOWANCE SOIL BEARING PRESSURE OF 96KPa (2000psi). 1. PROVIDE EXTRA SETS OF TIES AT 100 O.C. FOR TIED COLUMN REINFORCEMENT ABOVE AND
A. CONCRETE COMPRESSIVE STRENGTH @28 DAYS:
a. FOOTINGS, COLUMNS, BEAMS AND SLABS fc = 20.7 MPa (3,000psi) CONCRETE SHALL REPORT TO THE ENGINEER IN WRITING, THE ACTUAL SOIL CONDITIONS BELOW BEAM-COLUMN CONNECTIONS FOR A DISTANCE FROM FACE OF CONNECTION EQUAL TO
b. SLAB ON FILL fc = 17.5 MPa (2,500psi) UNCOVERED AND CONFIRM ACTUAL BEARING CAPACITY OF SOIL BEFORE DEPOSITING CONCRETE. GREATER OF THE OVERALL THICKNESS OF COLUMN, 1/6 THE CLEAR HEIGHT OF COLUMN OR
B. REINFORCING STEEL BARS
a. FOR BARS 16mm AND GREATER (INTERMEDIATE GRADE DEFORMABLE BAR) fy = 275 MPa (40,000psi)
2. FOOTING SHALL REST AT LEAST 150mm BELOW NATURAL GRADE LINE UNLESS OTHERWISE 450mm. TYP. DETAIL OF COL. LAP SPLICE
INDICATE IN PLANS. NO FOOTING SHALL REST ON FILL. 2. COLUMN TIES SHALL BE PROTECTED EVERYWHERE BY A COVERING OF CONCRETE CAST
b. FOR BARS LESS THAN 16mm (STRUCTURAL GRADE DEFORMED BAR)
C. STRUCTURAL STEEL ASTM-A36
fy = 230 MPa (33,000psi)
3. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE 75mm CLEAR FOR CONCRETE MONOLITHICALLY WITH THE CORE WITH A MINIMUM THICKNESS OF 40mm AND NOT LESS THAN & EXT. GIRDER TO COL. CONNECT
FOR TRUSSES, BRACINGS, & STRUTS fy = 248 MPa (36,000psi) DEPOSITED THE GROUND AND 50mm FOR CONCRETE DEPOSITED AGAINST A FORMWORK. 40 TIMES THE MAXIMUM SIZE OF COARSE AGGREGATE IN MILLIMETERS.
D. PURLINS 3. WHERE COLUMNS CHANGE IN SIZE, VERTICAL REINFORCEMENT SHALL BE OFFSET AT A SLOPE
4. IN CASES WHERE THE SOIL CONDITION IS SUCH THAT THE MINIMUM ALLOWABLE SOIL PRESSURE
COLD FORMED LIGHT fy = 248 MPa (36,000psi)
E. MASONRY UNIT (CHB) OF 96KPa (2000psi) CAN NOT BE ATTAINED AT A PRACTICAL DEPTHS THE USE OF MICROPILES, MONOLITHICALLY WITH THE CORE MINIMUM THICKNESS OF 40mm AND NOT LESS THAN 40 TIMES NOTES ON BEAMS AND GIRDERS
NON-LOADING BEARING CHB WALLS fm' = 3.45MPa (500psi) BORED PILES, OR DRIVEN PILES MAY BE ADOPTED IN LIEU OF STANDARD ISOLATED FOOTINGS. THE MAXIMUM SIZE COARSE AGGREGATE IN MILLIMETERS. 1. UNLESS, OTHERWISE NOTED IN PLANS, CAMBER ALL BEAMS AND GIRDER AT LEAST 6mmØ FOR
F. WELDS E - 60XX ELECTRODE 4. UNLESS OTHERWISE INDICATED IN THE PLANS, LAP SPLICES FOR VERTICAL COLUMN EVERY 4.50 M OF SPAN, EXCEPT CANTILEVERS FOR WHICH THE CAMBER SHALL BE AS NOTED IN
G. STRUCTURAL BOLTS ASTM-A307 a. Ft = 96.60 mPa (14,000psi) NOTES ON REINFORCEMENT REINFORCEMENTS SHALL BE MADE WITHIN THE CENTER HALF OF COLUMN HEIGHT, AND THE PLANS OR AS ORDERED BY THE ENGINEER BUT IN NO CASE LESS THAN 20mm FOR EVERY 3.0 M
b. Ft = 69.00 mPa (10,000psi) SPLICE LENGTH SHALL BE LESS THAN 40 BAR DIAMETERS, WELDING OR APPROVED
1. UNLESS OTHERWISE NOTED IN PLANS, THE YIELD STRENGTH OF REINFORCING BARS SHALL BE: OF FREE SPAN.
A. FOOTINGS, FOOTING BEAMS AND GIRDERS ------------------------------------------- fy = 275MPa (40,000psi) MECHANICAL DEVICES MAY BE USED PROVIDED THAT NOT MORE THAN ALTERNATE BARS ARE
3.0 IN THE INTERPRETATION OF THE DRAWING DIMENSIONS SHALL GOVERN. DISTANCES AND SIZES 2. TYPICAL BARS BENDING AND CUTTING DETAILS FOR BEAMS SHALL BE AS SHOWN IN FIG. B-1.
B. COLUMNS AND SHEAR WALLS ------------------------------------------------------------ fy = 275MPa (40,000psi) WELDED OR MECHANICALLY SPLICED AT ANY LEVEL AND THE VERTICAL DISTANCES BETWEEN
SHALL NOT BE SCALED FOR CONSTRUCTIONS PURPOSES
C. BEAMS AND GIRDER ----------------------------------------------------------------------------- fy = 275MPa (40,000psi) THESE WELDS OR SPLICES OF ADJACENT BARS IS NOT LESS THAN 600mm.
4.0 IN REFERENCES TO OTHER DRAWINGS, SEE ARCHITECTURAL DRAWINGS FOR DEPRESSIONS IN L1 L2
FLOOR SLABS, OPENINGS IN THE WALLS AND SLABS, INTERIOR PARTITIONS, LOCATIONS OF D. NON-LOAD BEARING WALL PARTITIONS, BEDDED SLABS
DRAINS ETC. FLOOR & ROOF SLABS PARAPETS, CATCH BASIN, SIDE WALK ----------------- fy = 275MPa (40,000psi) H L131 L113 L213 L231
5.0 IN CASE OF DISCREPANCIES AS TO THE LAYOUT, DIMENSIONS AND ELEVATIONS BETWEEN THE 2. ALL REINFORCING BARS SIZE 10mm OR LARGER SHALL BE DEFORMED IN ACCORDANCE WITH THE
STRUCTURAL PLANS AND ARCHITECTURAL DRAWINGS, THE CONSTRUCTORS SHALL NOTIFY ASTM A-706 BARS SMALLER THAN 10mm MAY BE PLAIN. CROSS-TIE
BOTH THE STRUCTURAL ENGINEER AND ARCHITECTS. 3. SPLICES SHALL BE SECURELY WIRED TOGETHER & SHALL LAMP OR EXTEND IN ACCORDANCE w/
350mm. MAX.
6.0 ALL CONCRETE WORKS AND CONCRETE REINFORCEMENTS HALL BE DONE IN ACCORDANCE TABLE B (TABLE OF LAP SPLICE & ANCHORAGE LENGTH) UNLESS OTHERWISE SHOWN DRAWINGS,
WITH THE ACl.318-14M BUILDING CODE REQUIREMENT AND ALL STRUCTURAL STEEL WORKS SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE.
ACCORDING WITH THE WITH AISC-05 IN SO FAR AS THEY DO NOT CONFLICT WITH THE LOCAL
10
H
L151 L115 L251 L215
dm
BUILDING CODE REQUIREMENT. NOTES ON CONCRETE SLABS
in.
TOP BARS
7.0 ACI REFERS TO AMERICAN CONCRETE INSTITUTE, AISC REFERS TO AMERICAN INSTITUTE OF 1. ALL SLAB REINFORCEMENTS SHALL BE 20mm CLEAR MINIMUM FROM BOTTOM THE TOP OF SLAB.
STEEL CONSTRUCTION AND ASTM REFERS TO AMERICAN SOCIETY FOR TESTING MATERIALS. 2-12mm Ø SIDE WEB BARS
2. UNLESS OTHERWISE SHOWN, REINFORCEMENT IN CONTINUOUS ELEVATED SLAB SHALL BE CUT AS BARS BOTTOM BARS
8.0 CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE FOLLOWS; Close rings
SHOWN OR MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS. FIGURE B-1
9.0 SHOP DRAWING WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS, BENT BAR 1.5d 1.5d
MISCELLANEOUS IRON, PRE-CAST CONCRETE, ETC. SHALL BE SUBMITTED FOR ENGINEERS
APPROVAL BEFORE FABRICATION. L1 L2
10.0 CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS,
L1/4 L1/4 L2/4 300 300
EQUIPMENT AND MECHANICAL BASES THAT ARE REQUIRED BY THE ARCHITECTURAL,
ELECTRICAL AND MECHANICAL DRAWINGS.
TOP BAR
11.0 ALL RESULTS OF THE MATERIAL TESTING FOR CONCRETE, REINFORCING BARS & STRUCTURAL
STEEL MUST BE NOTED & APPROVED BY THE MATERIALS ENGINEER/STRUCTURAL DESIGNER.
Slope 1:10
BOTTOM BAR
GRID BEAM DETAILS
GENERAL CONSTRUCTION NOTES
TABLE 'A' TABLE 'B' SEE CONSTRUCTION NOTES 4-Ø16 VERT. BARS
NOTES ON STIRRUPS
TENSION BARS COMPRESSION BARS REINFORCING CONCRETE LINTEL BEAMS IN FOR MASONRY WALL REIN-
FORCEMENTS (TYPICAL) 4-Ø16 VERT. BARS
550
1. ALL REINFORCEMENT SHALL BE BENT COLD UNLESS OTHERWISE
550
PERMITTED BY THE STRUCTURAL ENGINEER.
BAR SIZES fc`= 20.7MPa(300psi) fc`= 27.6 MPa (4000psi) BAR SIZES fc`= 20.7MPa(300psi) fc`= 27.6 MPa (4000psi)
NAT. GRD. LVL.
(DEFORMED MM)
EMBEDMENT LAPPED EMBEDMENT LAPPED
(DEFORMED MM)
EMBEDMENT LAPPED EMBEDMENT LAPPED DOWEL BARS TO MATCH 2. AS SHOWN IN THE DESIGN DRAWINGS OR PERMITTED BY THE
CHB VERTICAL BARS
STRUCTURAL ENGINEER.
∅10
∅12
300 300 300
300
300 ∅10
∅12
225 300 200
250
300
LINTELS IN BLOCK WALLS Ø10 BOTT. BARS
@ 300 O.C.
550 550
250
300 300 300 275 300 300
3. TIES & CLOSE STIRRUPS MUST BE AT 135.
∅16 300 400 300 400 ∅16 350 400 325 400 3-Ø10 BOTT. BARS
∅20 400 550 350 500 ∅20 450 500 475 500 CLEAR TOTAL MIN. HEIGHT OF REINFORCEMENT
TYPICAL CONNECTION DETAIL
∅25 600 800 550 750 ∅25 550 625 550 625
SPAN LENGTH fc' LINTEL 400 OF R.C. WALL AT CORNERS
∅28 750 1000 650 850 ∅28 625 675 625 675 180 DEG. HOOKS
(L) (L+0.40M) (MPa) (mm) BOTTOM TOP STIRRUPS Dbar
D+12db
∅32 950 1300 850 1100 ∅32 700 775 700 775
DOWEL
3. VALUES GIVEN ABOVE CAN ALSO BE USED FOR COLUMNS
1.80 M 2.20 M 200 1-Ø 12 1-Ø 10 Ø6mm @ 200mm (TYP.) 2. WELDS SHALL DEVELOP THE FULL STREBGTH OF MEMBERS JOINED UNLESS
90 DEG. HOOKS
400
OTHERWISE SHOWN OR DETAILED IN THE DRAWINGS. Dbar
FIN. FLR. LVL.
Ø6mm @ 200mm NOTES ON STRUCTURAL STEEL
250
2.10 M 2.50 M 250 1-Ø 12 1-Ø 10
L
12db
3. IF THE BEAM REINFORCING BARS END IN A WALL, THE CLEAR DISTANCE FROM THE BAR TO THE 2.40 M 2.90 M 17.0 250 1-Ø 12 1-Ø 10 Ø6mm @ 200mm 6-Ø10 BARS (AS SHOWN ) 1. STRUCTURAL STEEL TO BE USED FRO FABRICATION AND ERECTION OF THIS D
FARTHER FACE OF THE WALL IS NOT LESS THAN 25mm. EMBEDMENT LENGTH SHALL BE SHOWN IN A Ø10mm @ 200mm Ø10 BOTT . BARS @ 300 O.C.
2.70 M 3.10 M 250 1-Ø 16 1-Ø 12 400 STRUCTURE SHALL COMPLY WITH ALL THE PERTINENT PROVISION OF AISC
TABLE 'A' FOR TENSION BARS TABLE 'B' FOR COMPRESSION BARS UNLESS SPECIFIED IN PLAN. TOP BARS SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL
SHALL NOT BE SPLICED WITHIN THE COLUMN OR TWO STIRRUPS SHALL BE PROVED AT ALL SPLICES. 3.00 M 3.40 M 300 1-Ø 16 1-Ø 12 STEEL FOR BUILDING LATEST EDITION.
MAIN BAR END HOOKS
Ø10mm @ 200mm (ALL GRADES)
4. IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS, USED 25mm BAR SEPARATORS SPACED AT 3.30 M 3.70 M 20.0 300 1-Ø 16 1-Ø 12 DOWEL TO MATCH
Ø10mm @ 200mm CHB VERT. BARS 2. ALL STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A36 STRUCTURAL BAR SIZE DIAMETER 180° HOOK 90° HOOK
1.0M ON CENTER ON NO CASE SHALL THERE BE THAN TWO (2) SPARATORS BETWEEN LAYERS OF BARS. 3.60 M 4.00 M 300 1-Ø 20 1-Ø 12 WHERE DEPRESSED STEEL UNLESS OTHERWISE INDICATED.
(DEFORMED) (mm)
D+2db L L
Ø10mm @ 200mm
300 SLAB OCCURS 10mm ∅ 60 75 125 150
5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS OR STEEL SHAPES SHALL BE AS SHOWN IN 3. ALL WELDED CONNECTIONS SHALL DEVELOP THE FULL STRENGTH OF THE
DOWEL
(TYP.) 12mm ∅
FIGURE B-2 UNLESS ELSEWHERE. 75 100 150 200
400
12 THK. EXPANSION JOINT
MEMBERS CONNECTED. 16mm ∅ 95 125 175 250
WITH MASTIC FILLER FIN. FLR. LVL.
4. UNLESS OTHERWISE SPECIFIED ALL WELDING RODS SHALL CONFORM WITH E60
250
20mm ∅ 115 150 200 300
(DOWEL)
MAIN REINFORCEMENT MAIN REINFORCEMENT 6-Ø10 BARS (AS SHOWN )
5. ALL BOLTS USED UNLESS OTHERWISE SPECIFIED SHALL BE ASTM A307 BOLTS. 28mm ∅ 240 300 350 550
400
t OR 1/4 D
t OR 1/4 D
L
OTHERWISE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER.
TYP. DET. FOR SLEEVES TYP. DET. FOR SLEEVES CORNER WALL OPENING OR END WALL 2. NO PIPES SHALL BE ALLOWED TO PASS THRU BEAMS VERTICALLY. LE
THRU CONCRETE BEAM THRU CONCRETE BEAM 3. NO PIPES SHALL BE EMBEDED IN COLUMNS.
VERIFY DEPRESSION
D
6d
FIG. B-2 FIG. B-3
b
CHB WALL R.C. COLUMN OR WALL 30 BAR DIA.
(min.)
30 BAR DIA.
(min.)
NOTES ON CONSTRUCTION JOINTS IN CONCRETE
D=FOR BEAM
t=FOR SLAB
1-Ø16 VERT. BARS DOWEL BARS TO MATCH L1
CHB HOR. BARS 1. WHERE A CONSTRUCTION JINT IS TO BE MADE, THE SURFACE OF CONCRETE L
12 THK. EXPANSION JOINT 12 THK. EXPANSION JOINT
WITH MASTIC FILLER WITH MASTIC FILLER SHALL BE CLEANED AND ALL LAITANCE AND STANDING WATER REMOVED SHEAR
6. WHEN A BEAM CROSSES A GIRDER, REST BEAM ON TOP OF GIRDER BARS, BEAM REINFORCING BARS KEY SHALL BE PROVIDE AT THE JOINT.
SHALL BE SYMMETRICAL ABOUT THE CENTERLINE WHENEVER POSSIBLE.
(DOWEL)
(ALL GRADES)
7. GENERALLY, NO SPLICES SHALL BE PERMITTED AT POINTS WHERE CRITICAL BENDING STRESSES OCCUR, FOR SIZE AND SPACING
CONTINUOUS (TOP & BOTT. BARS)
D=FOR BEAM BAR SIZE DIAMETER
180° HOOK 90° HOOK
SPLICES WHERE SO PERMITTED SHALL BE INDICATED IN TABLE 'A' AND 'B'. WELDED SPLICES SHALL OF HOR. & VERT. BARS
400 2t=FOR SLAB MAIN REINFORCEMENTS WHERE JOINTS IS AT POINT OF
(DEFORMED) (mm)
SEE CONSTRUCTION NOTES. TO BE CONTINUOUS STRESS, PROVIDE SHEAR RODS D+2db L L
DEVELOP IN TENSION AT LEAST 125% OF THE SPLICED YIELD STRENGTH OF THE BAR NOT MORE THAN (DOWEL) WITH ENGINEERS APPROVAL
30 BAR DIA. (min.) Ø10x1000 @ 10mm ∅ 40 125 85 100
50% OF THE BARS AT ANY ONE SECTION IS ALLOWED TO BE SPLICED THEREIN. INTERSECTION WALL INTERSECTING R.C. COLUMN OR WALL @ 300 O.C. 30Ø BAR 30Ø BAR 12mm ∅ 50 165 115 115
TYPICAL DETAIL FOR BEAM 40
(MIN.)
50
(MIN.)
16mm ∅ 65 200 140 150
D/3
TYPICAL CONNECTION DETAIL OF MASONRY WALL OR SLAB CHANGE SOFFIT
D/3
t/3 t/3
20mm ∅
D
115 300 165 300
t/3
D/3
32mm ∅ 150 335 230 405
SLAB
NOTES ON CONCRETE HOLLOW BLOCK WALLS BEAM
NOTES ON CONCRETE HOLLOW BLOCKS WALLS REINFORCEMENTS FIN. FLR. LVL. WALL REINFORCEMENT VERTICAL PLANS FOR SLAB OPENING LOCATION.
2-Ø12 BOTT BARS
THICKNESS HORIZONTAL VERTICAL REMARKS SECTION
BLOCK THICKNESS REINFORCEMENT NOTES
ELEVATION SECTION 100mm ∅ 10mm @ 250mm O.C. ∅ 10mm @ 300mm O.C. HORIZONTAL BARS
HORIZONTAL LAPPED A. MINIMUM LAPS AT SPLICE= 0.25 M VER. BARS DOOR
125mm ∅ 10mm @ 200mm O.C. ∅ 10mm @ 250mm O.C. AT CENTERS VERTICAL
75 mm 10mm Ø EVERY 3RD LEVEL 10mm Ø @ 600mm O.C. B. PROVIDE RIGHT ANGLED REINFORCEMENT TYP. DET. OF LINTEL BEAM AT CHB WALL OPENING BARS STAGGED OUT HOR. BARS
OPENING
AT CORNERS 0.92 m LONG 150mm ∅ 12mm @ 250mm O.C. ∅ 12mm @ 300mm O.C.
125 mm 10mm Ø EVERY 3RD LEVEL 10mm Ø @ 600mm O.C.
C.WHERE CHB OR CER. BLK. WALL DOWELS 38mm CLEAR WINDOW
150mm 10mm Ø EVERY 3RD LEVEL 10mm Ø @ 600mm O.C. WITH THE SAME SIZE AS VER. OR HOR. OPENING
REINFORCEMENT SHALL BE PROVIDED DOWEL BARS TO
200 mm 12mm Ø EVERY 3RD LEVEL 10mm Ø @ 600mm O.C. FLR. SLAB OR BEAM MATCH VERT. BARS REINFORCED BARS SHALL HAVE 25m CLEAR CONCRETE COVER FROM FACE OF WALL EXCEPT FOR WALLS
IN CONTACT WITH THE GROUND WHERE A MINIMUM OF 60mm SHALL BE PROVIDED AND FOR EXPOSED
(DOWEL)
VERIFY ARCHITECTURAL
FOR FLOOR SLAB ONLY 3. UNLESS OTHERWISE NOTED IN THE PLANS, ALL OPENINGS IN WALLS 250mm OR THICKER SHALL BE
REINFORCED AROUND WITH 2-20mm∅ BARS. FOR 225mm, 200mm, 175mm, 150mm THICK
WALLS, USE 2-16mm∅. FOR 125mm AND 100mm THICK WALLS, USE 2-12mm∅ BARS. ALL WALLS SPANNING SHALL
TYP. SECTION OF MASONRY HAVE VERTICAL REINFORCEMENT BENT A U-FORM LIKE STIRRUPS AND SPACED ACCORDING TO THE SCHEDULE
PARTITION REINFORCEMENTS UNLESS OTHERWISE NOTED.
A B C D
1400
75
4000 1800 4000
525
9800
F1-C1 F1-C1 F1-C1 F1-C1 FTB FTB
1400
350
FTB-1 FTB-1
5
525
12-25mmØ VERT. BARS
WITH 10mmØ ties 1@50,
1800 7-20mmØ BARS PLAN
FTB-1 5@100,REST @ 150mm O.C.
3000 FTB-1 EACH WAY
F1-C1 F1-C1
WF-1
FTB-1
4 FTB-1 2 DETAIL OF COLUMN & FOOTING (F1-C1
3000
F1-C1 F1-C1
S-1 SCALE 1:50 MTS
1800
3 10200
FTB-1 FTB-1
2400 F1-C1 F1-C1 F1-C1 2400
150
FTB-1
2
3000 3000
F1-C1 F1-C1 F1-C1
GROUND G.L 10mm Ø @ EVERY 3rd LAYER,
FTB-1 FTB-1 HORS BARS
1 FINISH G.L
10mm Ø @ 600mm O.C.,
5800 4000 NATURAL G.L VERT. BARS
9800 300
10mm Ø X 650mm LONG @
600mm O.C., DOWEL BARS
FTB
100mm THK. WELL-COMPACTED
1 FOUNDATION PLAN GRAVEL FILL
S-1 SCALE 1:100 MTS
A B C D
A B C D
9800
1175 4000 1800 4000 1175
9800
4000 1800 4000
CB-1
CB-1
1875
GB-1 GB-1 GB-1 5 B-1
5 RB-1
3000 B-3
RB-3
3000
B-2
RB-2
4
4 1800
B-5
1800
3
TRUSS - 1
TRUSS - 1
TRUSS - 1
TRUSS - 1
TRUSS - 1
RB-5
3
RB-4
2400
2400 B-4
2
2
3000
3000 B-6
RB-6
1
1
CB-1
CB-1
1475
GB-1 GB-1
1 2 1 1 2 1 1 2 1 1 2 1 1 2 1
L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4
4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ
250
2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ
L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 10mm Ø STRR.
10mm Ø STIRRUPS 1@50, 10 @75, 10mm Ø STIRRUPS 1@50, 10 @75, 10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C. REST @ 150mm O.C. REST @ 150mm O.C.
10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C. 2-16 mm Ø
DETAIL ON RB-1 DETAIL ON RB-2 DETAIL ON RB-3
400
4-16 mm Ø
1 2 3 4 5 6 3 2 1
10200 10200
SECTION-1
1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1
L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4
250
4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ
L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 4-16 mm Ø
400
10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C.
10mm Ø STIRRUPS 1@50, 10 @75, 10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C. REST @ 150mm O.C.
10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C.
10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C.
2-16 mm Ø
DETAIL ON RB-4 DETAIL ON RB-5
SECTION-2
6 6 6
9800
5800 4000
DETAIL ON RB-6
A B C D A B 4 5
9800 3000
4000
1 2 1 1 2 1 1 2 1 1 2 1 1 2 1
L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4
4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ
250
2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ
L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 10mm Ø STRR.
10mm Ø STIRRUPS 1@50, 10 @75, 10mm Ø STIRRUPS 1@50, 10 @75, 10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C. REST @ 150mm O.C. REST @ 150mm O.C.
10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C. 2-16 mm Ø
DETAIL ON B-1 DETAIL ON B-2 DETAIL ON B-3
400
4-16 mm Ø
1 2 3 4 5 6 3 2 1
10200 10200
SECTION-1
1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1
L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4 L/4
250
4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 4-16mmØ
L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 L/5 4-16 mm Ø
400
10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C.
10mm Ø STIRRUPS 1@50, 10 @75, 10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C. REST @ 150mm O.C.
10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C.
10mm Ø STIRRUPS 1@50, 10 @75,
REST @ 150mm O.C.
2-16 mm Ø
DETAIL ON B-4 DETAIL ON B-5
SECTION-2
6 6 6
9800
1 2 1 1 2 1 1 BEAM DETAIL
S-3 SCALE 1:80 MTS
5800 4000
DETAIL ON B-6
GRID
1 DETAIL FOOTING
S-4 SCALE 1:80 MTS
D
A B C D 1250
A
2 1100 100 50
1250
S-5
12mm Ø VERT. BARS 1100 100 50
975
2900 12mm Ø VERT. BARS @ 200mm
900
400
400
1200 RB-1
CB-1
GB-1
RB-1 GB-1
1200 CB-1
7
S-5
6
S-5
5
S-5 S-5
4 DETAIL A DETAIL B
W.M.
W.M.
T.C. W.M. W.M.
T.C. W.M.
W.M.
250
T.C. 250
T.C. B.C. B.C.
m THICK
624 6mm THICK B.C. B.C.
TYPICAL GUSSET, TYPICAL 6mm THICK B.C. B.C.
W.M. W.M.
GUSSET, TYPICAL
W.M.