Engine/System > Starting Systems for Marine Propulsion and Auxiliary Engines
Comments/ Explanations > Separate ground starters (SGS) are referred to as “case isolated” in other industry segments. The
case isolation was developed to preclude large damaging currents from flowing through bolted
engine junctions during starting. The starter does this by providing a direct ground path back to
the negative battery post. This starter was not designed to maintain high isolation of the ground
path from the starter case/engine when the starter is not operating. It will not sustain a resistance
larger than 20K Ohms for the life of the starter (More than 1.5 milliamp for a 24 volt system).
Some ground fault monitoring systems have been found as high as 2 mega Ohms (0.012
milliamps). For marine systems that have critically high leakage current monitoring; a
ground/negative side relay will need to be installed to prevent fault monitoring systems from
activating. This is a builder, operator specified feature.