CONTENTS
4 6 15 17 page
1. Cautions for using 2. About product 3. Using refined salt 4. Inspection
- Components - Cautions - Cautions
- Specification & Features - Making saline solution - Troubleshooting
- How to use - Replacement period
- Applications & Block diagram
- Part list
* Certifications
www.naoclean.com
page 4
1. Cautions for using
Precautions for safe operation ※ Please observe the following instructions to prevent unexpected hazards of damage and hurt. Cautions
Correct handling
- Always keep clean the surface of device. - Do not operate the machine for a long time more than 20
- Keep the device away from the children or unskilled people. minutes with 80bar at once (Continually). A long time op-
- You can prevent from unexpected situations by keeping your pace erating without rest may cause the heat and damage of parts.
constantly while using the device. If you need to use more, please operate the machine after
- Wear a protective goggles while using the device. Small pieces of getting enough rest to cool down.
debris may be flying around. - Do not leave the motor idling for a long time. A long time idling
- Never spray water or any solution on the main unit or a person. may cause the damage of the motor or other parts.
- Keep the Spray gun hose away from the hot air exhaust. - When you are not making disinfecting water or you don’t have
- Please check the every hose is perfectly connected. solution in the tank, you must turn off the Power switch.
- To avoid the danger of falling, keep the device on the flat ground - Never use the device with any chemical that is not described.
and maintain level of the device. - Please stop using the device when the surrounding temperature
- Please fix the device when you spray the disinfectant, because it drops to below zero degrees, and drain water inside the tank
needs earth ground. completely.
- Beware of sharp edges of the motor cover. - Do not keep the device where ventilation does not function prop-
- Do not disconnect the gun from the hose as long as the pressure erly or in oily, smoky, humid, dusty and water splashing places.
remains. Because the high-pressure water inside the hose may - Only use the tap water or suitable for drinking water standards.
spurt and hurt the user. - Do not use hot water and never use the water which has a lot
- Do not attempt to disassemble, repair or alter the device. of salinity because it makes some error as the concentration is
(You may suffer from electric shock or hurt.) not proper.
HOW TO PROTECT YOUR DEVICE IN WINTER SEASON:
TURN OFF THE POWER AND DRAIN ALL REMAINING WATER FROM THE STORAGE TANK BY PULLING THE SPRAY GUN SUFFICIENTLY.
AFTER DRAINING, UNPLUG THE POWER CORD AND KEEP IT INDOORS. IF NOT, INSIDE PARTS MAY FREEZE AND DAMAGE.
www.naoclean.com
page 6
2. About product > Components / Specification & Features / How to use / Applications
Front Back
Handle
Hose reel
Hose reel
Cover handle
Hanger
Main body
Urethane wheel
Front panel
Drain hole
Please put the provided
drain hose (5/16”PE) into
the hole to drain.
The Hose reel part is upgraded to Auto hose reel.
(The content is subject to change due to continued research and development.)
page 7
2. About product > Components / Specification & Features / How to use / Applications
Right Left
Nozzle
(25, 40 degrees)
Accessories
box Pump connection
hose
Level
indicator Earth leakage
circuit breaker
Nut cover Pressure
Water controller
inlet
part
www.naoclean.com
page 8
2. About product > Components / Specification & Features / How to use / Applications
Control panel
Disinfectant button Power switch
It generates disinfectant. The power is switched on and motor is working.
(You can use the water from the high-pressure spray gun.)
DISINFECTANT
POWER POWER
DISINFECTANT ERROR
GENERATING
Model DES-WA50
1) Convenience and economics.
Dimension W615 X D767 X H1005mm
- Finish the cleaning, sterilizing and deodorizing at once.
Rated Voltage AC 220V, 50Hz, 2.5kW (±10%) - Save the water consumption drastically.
Weight About 50kg - Very low operation cost by replacing expensive chemicals.
Storage tank 50L
2) Powerful sterilizing, deodorizing and cleaning capability.
Max pressure 80~100 bar - Remove and clean various harmful germs and foreign matters.
Flow rate About 6~7L/min. (±10%) - Sterilize and deodorize processing facilities and equipments.
Electrolysis Without membrane - Sterilize floor, wall and facilities of working spaces.
method - Remove bad odor in toilets and bathrooms.
- Prevent slipperiness with high-pressure based powerful cleaning capability.
Active chlorine About 100ppm (±10%)
pH 7.0~7.5pH 3) Environment-friendly and highly stable.
Additive Refined salt (Salinity more than 88%) - No secondary contamination.
- Do not use chemical agent.
Condition of Surrounding temperature 5~40℃ - Do not remain strong smell.
use Water temperature 5~30℃ - No residual toxicity.
Humidity less than 95% RH - Safe for humans and environment.
Nozzle High-pressure nozzle (25/40 degrees)
4) Portability and effectiveness.
Length of hose 8~10m - Easy to move with the storage tank’s wheel.
- Conveniently usable in a small or narrow spaces with high-pressure spray gun.
Accessories Measuring cup, Dilution bottle, Nozzle, Oil tray - Practically no restriction of operation as far as electric power is available.
Bottle for changing the pump oil, Water inlet hose
www.naoclean.com
page 10
2. About product > Components / Specification & Features / How to use / Applications
1. Measure a suitable amount of clean, refined salt with 88% salinity ※Precautions for cleaning with disinfectant
(or higher) with the measuring cup, and put it into the dilution bottle.
- Make sure to dissolve the prescribed amount of salt completely before
2. Add tap water to 2/3L of the bottle and melt them completely. pouring it into the tank. (Too much salt may cause an error preventing
disinfectant from being generated. In such a case, turn off the Disinfectant
3. Pour it into the tank and add tap water to 25 or 50L line.
button, drain some of the saline solution from the tank by pulling the gun
4. Connect the power plug. trigger and add some water in the tank to lower the concentration of the
saline solution. After that, turn on the Disinfectant button, and try again.)
5. Press the main Power switch. (At the initial operation, spray may not
work properly with idling of the motor because water has not been - In case of the motor idling continuously when you press the Disinfectant
supplied to the pump yet. In such a case, pull the gun trigger button, the buzzer will make a sound. In this case, shut off the power and
several times until the spray works normally.) refill the brine into the tank. After that please turn on the power button
while pulling the gun trigger to remove the pressure inside the pump and
6. If there is a problem with the high-pressure spray, wait a few hose parts.
moments until the inside air is completely removed before attempting
- Do not leave saline solution in the tank for an extended period of time.
to use the device again.
- Make sure to use just the right amount of disinfectant as needed.
7. Press the Disinfectant button.
- If it is used on ferrous material, rinse with clean water after using.
8. Hold the spray gun with both hands (because of high-pressure), - It may cause corrosion. (Refer to page 17)
aim it toward your target area and shoot it. (You can choose the type
of spray nozzle.) - When you are not using disinfectant, turn off the Disinfectant button.
- If the device is not powered up even after it is properly plugged up and
9. After using the disinfectant, please refill the tank with tap water and
switched on, turn on the leakage circuit breaker. (ELCB) (Refer to page 7)
clean inside the device by running it once again.
page 11
2. About product > Components / Specification & Features / How to use / Applications
4. Hold the spray gun with two hands (because of high-pressure), 3. Connect the power plug and press the main Power switch.
aim it toward your target area and shoot it. (You can choose the 4. Spray detergent on areas stained with greasy dirt.
type of spray nozzle.) 5. After some moment, remove the detergent bottle and replace it
with original nozzle.
6. Hold the spray gun with two hands (because of high-pressure),
and pull the gun trigger. Remove greasy dirt by spraying water
and rinse with water.
※Precautions for cleaning with water (or detergent)
- Do not operate the device while the tank is empty.
- Do not turn on the Disinfectant button.
- Do not leave the motor idling for a long time. (The motor may be overheated
and broken down.)
- Before operating the device, press the Power switch and pull the gun trigger
several times. (The device may not run at the first attempt due to air.)
www.naoclean.com
page 12
2. About product > Components / Specification & Features / How to use / Applications
If the nozzle becomes clogged with foreign materials, the pump pressure
will pulsate. Clean the nozzle and other parts immediately with the fol-
lowing instructions:
Push the connector to the back and change the nozzle. After When it is difficult to roll or unroll the hose
that, turn it back as original place. ※Do not put your face on the
front of the gun when the device is working. If the hose is too stiff to roll or unroll from hose reel, turn off the power, release
the pressure by pulling the gun trigger and then roll or unroll the hose.
page 13
2. About product > Components / Specification & Features / How to use / Applications
Use the pliers on the lower part. Loosen one screw and take the Adjust the pressure by turning the
pliers out. pliers from side to side into the hole.
www.naoclean.com
page 14
2. About product > Components / Specification & Features / How to use / Applications
Clean the fish, meat, food processing equipments Floor, drain, stairs and all around the workplaces.
The mobility of this model enables users to remove effectively the It disinfects effectively and removes bad odor in many places
bacteria or microbe. Especially it is mainly recommended to clean where should be cleaned including fish & meat processing fac-
the fish and meat processing equipments after work. A strong tories, feeding facilities, kitchens, floor, drain and all around the
high- pressure removes the food particles stuck in a small niche workplaces.
and bad odor completely. It prolongs the life time of your process-
ing equipments and prevents secondary pollution generated from
them.
Public facilities
You might encounter error although you use the regulated amount of saline solution, because it may vary depending on the water
quality and temperature. If the water has salitiny itself, the machine does not work normally. To solve this problem, you have to reduce
the amount of salt or add the tap water to lower the salt concentration.
www.naoclean.com
page 16
3. Using refined salt > Cautions / Making saline solution
The ratio of water and salt. ※The amount of salt may vary depending on the water quality.
50L 25L
200g 100g
150g Dissolve salt Add water 75g Dissolve salt Add water
with water up to 50L with water up to 25L
Powder type salt Powder type salt
(salinity 99%) (salinity 99%)
3. Do not use disinfectant in the cultivation of plants, animals, fish and shellfish, etc. ABS resin
4. Be careful that the solution may bleach the colored textiles. polyethylene
5. Be aware of the Corrosion-resistant table on the right side, so please wash it once with acrylic
tap water after using. polypropylene
6. Be sure to wash the Metal-drainage-pipe with tap water after using the large amount teflon
silicon
of disinfectant, because it may cause corrosion.
epoxy resin
7. Chlorine concentration may be degraded by ultraviolet rays, high temperature or long
urea resin
period of time. Butyl-rubbe, NBR
8. If the saline solution remains in the tank for an extended period of time, it may cause natural, urethane rubber
corrosion. titanium, glass, ceramics
9. If you exceed the available chlorine concentration, rinse with tap water after using the stainless steel
disinfectant. plating, copper
phosphor bronze
brass
※Please do not spray on the materials which are listed on the right table marked as aluminium alloy
[weak]. steel
www.naoclean.com
page 18
4. Inspection > Cautions / Troubleshooting / Replacement period & Block diagram / Part list
Troubleshooting Do not voluntarily modify or repair the parts inside the device.
The device - Power is not connected well. - Measure supply voltage and see if it is a proper range.
does not operate. - Socket is loosen or defective. - Check the power cord for cracking or try another socket.
- Supply voltage is too low. - Turn on the ELCB again. Pull out a Rubber stopper and raise the ELCB
- Earth leakage circuit breaker (ELCB) is blocked. switch on the left side of the body.)
- When the motor was heated a lot. - Turn off the power and wait until the overheated motor cools down.
(It is result that the sensor of preventing overheat is working.)
The amount of - The amount of spray is too small. - Disconnect the nozzle from the gun and dust debris inside the each
spray is irregular. - Irregular spray. part, or use some pin to unblock the nozzle.
(Make sure to turn off the power before, and do not look into the spray nozzle
from the front.)
- Check if the drain hose is connected. It must be removed when using.
Pressure is - Air goes into the pump or the High-pressure hose. - Check if High-pressure hose is damaged or connecting parts worn out.
too low. - High-pressure hose or gun was blocked. - Clean up or replace the hose and gun. (Refer to the page 12)
- The pressure lever was adjusted. - Close the pressure lever to the left side to increase the pressure.
- The moter’s filter was blocked. - Clean inside the moter according to the guide. (Refer to the page 19)
- Do not change the pump oil after using 50hr first - Clean inside the pump with karosene (or gasoline) and change with the
and every 100hr. fresh pump oil. (Refer to the page 20)
- The piston inside the motor was wore out. - Contact the distributor you purchased from.
page 19
4. Inspection > Cautions / Troubleshooting / Replacement period & Block diagram / Part list
How to solve abnormality at the beginning How to clean inside the pump (motor)
If the water does not come out from the trigger 1. Please disassemble the pump from the main unit.
at the beginning: 2. Loosen the 4 bolts. (Please note that the pump does not lose
Please use the provided Water inlet hose to connect from the any rubber packing.)
faucet to the water inlet part of the device(Refer to the page 7).
Quick coupling at the end of the hose must be tighten surely.
After that, run the tap water and push the Power button on
the device. You can find the water will flow out from the trigger
shortly when you push it. After checking the water flow out
from the trigger, close the faucet to stop the supply water and
disassemble the hose.
Please follow the way of use again(Refer to the page 10). 3. After disassembling, remove the plastic cover units aside and
※If you use the device after a long period, please follow take out the plastic units inside the hole.
this process to solve the abnormality at the beginning. 4. Please disassemble the stainless ring from the plastic unit by
5. turning.
After that, you can check the rounded plastic part with spring.
Please wash out this part with tap water.
6. After cleaning, please assemble it back tightly
and check if nothing has been left behind such
as rubber packings, plastic units, etc.
www.naoclean.com
page 20
4. Inspection > Cautions / Troubleshooting / Replacement period & Block diagram / Part list
Block diagram
A1
A2
95 Electrodes replacement period
96
97
98 소독수
The life time (approx. 10,000 hours)
Lamp 전해조
of the electrode may vary depend-
ing on water quality.
page 21
4. Inspection > Cautions / Troubleshooting / Replacement period & Block diagram / Part list
11 12
NO PART NAME QTY
1 PUMP ASSY 1
2 MOTER ASSY 1
9 10
3 ELECTROLYTIC ASSY 1
4 CONNECTING HOSE 1
6 1
5 CHECK VALVE 1
6 SMPS ASSY 2
7 EOCR 1
8 PCB ASSY 1
2 9 ERROR BUZZER 1
5 10 ELB 1
11 POWER CORD 1
12 POWER PLUG 1
7 8 4 13 AIR HOSE 1
14 QUICK COUPLING 1
3
14
13
www.naoclean.com
page 22
4. Inspection > Cautions / Troubleshooting / Replacement period & Block diagram / Part list
www.naoclean.com
page 24
Quality Warranty
Pro duct Name High-pressure disinfecting washer NaOClean-S
How to request for service
- If you find any abnormality or have a question while using this product,
Mo del DES-WA50
please contact a nearby distributor or our head office.
Warrant y Perio d One (1) year from the date of purchase - In order to request for services, you need to present this quality warranty
Date of purchase duly filled out. Therefore please keep it carefully. In case you get
Purchaser :
charged services, please make sure to keep the receipt carefully.
address
Point of purchase : Consumer damages compensation
address - Free services: For any failure related to the function and performance of the
product that takes place in the course of normal operation within the warranty period.
- Charged services
1. When the warranty period has expired;
2. During the warranty period, if failure was caused by;
- Careless handling of the product.
Regulations of Product Warranty - Unauthorized repair or alteration of the product.
- This product was manufactured through strict quality control and inspection. - Damage during transportation due to mishandling.
- Connection to a wrong power.
- Services arising from failure that takes place after the expiry of the warranty
period will be charged for.
- During the warranty period, one year from the date of purchase, this product ※ Please fill out the quality warranty completely and keep it carefully.
shall be serviced free of charge as far as manufacturing defect is concerned.
- This product is warranted in accordance with the description on the quality
warranty.