tec grout P TECHNICAL AND

REPAIR MORTARS

Cementitious non-shrink precision grout

PRODUCT
tec grout P is a ready-to-use free flow precision grout
made of sand, special cement and additives to achieve an
easy handling and high performances with no bleed and
zero shrinkage.

SCOPE OF USE
• Concrete jacketing for slabs, columns, beams and footings
• Void filling applications
• Filling of shutter tie rod openings
• Jointing and bedding of precast elements
• Jointing of formwork

ADVANTAGES
• Highly fluid
• Chloride and hydrogen free
• High early mechanical resistance PACKAGING
• Good resistance to chlorides and sulfates Leb Syria Jordan UAE Qatar Kuwait KSA Oman
• Easy application - - - 25 kg 25 kg 25 kg - 25 kg
• Excellent resistant to vibration and shock loads
• Pumpable

CHARACTERISTICS APPLICABLE STANDARDS


Appearance Grey powder ASTM C 1107
Grain size 0 to 1 mm
Wet density (kg/m3) 2.15 - 2.25
Mixing water 17% - 18% INSTRUCTIONS FOR USE
Initial Setting time (min) 255 PRODUCT PREPARATION
Final Setting time (min) 325 The mortar or grout is obtained by mixing 25kg of tec
Free from chlorides and metallic particles grout P with 4.25 to 4.5 lit of water.
Add the powder gradually to the water and mix for 3
COMPRESSIVE STRENGTH minutes. To ensure a homogeneous and uniform mix, an
AGE 1 day 7 day 28 day electric mixer must be used.
COMPRESSIVE ≥27 ≥50 ≥70 Do not mix with other hydraulic binders. The use of additives
STRENGTH BS EN 12190 BS EN 12190 BS EN 12190 is absolutely prohibited.
(N/mm²) Ideal application temperature is between + 5ºC and + 35ºC. If
STANDARD the application temperature is higher than 35 ºC, make sure
to use cool water to keep the mixed grout temperature
AGE 7 days 28 days below 30 ºC.
FLEXURAL 8 ≥ 10
STRENGTH (N/mm²) Webertec water 3/8 Volume
STANDARD BS EN 196-1 grout P aggregates in place
Fluid 25 kg 4.25 0 13 L
*Results obtained at fluid consistency under lab conditions at 25°C ± 2: consistency to 4.5 lit
17% water or 4.25 lit. per 25 kg bag. Plastic 25 kg 3.5 0 13 L
*Properties listed above are only based on controlled laboratory consistency to 3.75 lit
samples and tests: Results may differ based upon statistical variations Microconcrete 25 kg 3.75 10 kg
depending upon mixing methods and equipment, temperature, application to 3.87 lit
methods, test methods, actual site conditions and curing conditions.

1/2 Technical data sheet . Edition: 05.15-A www.sodamco-weber.com