General characteristics
Insulation class H Excitation system 6-wire SHUNT AREP+ / PMG
Winding pitch 2/3 (wind.6S - 6-wire / wind.6 - 12-wire) AVR type R150 R180
Number of wires 6 (12 option) Excitation system 12-wire (option) SHUNT AREP+ / PMG
Protection IP 23 AVR type R150 R180
Altitude ≤ 1000 m Voltage regulation (**) ± 0.8 % ± 0.5 %
Overspeed 2250 R.P.M. Total Harmonic Distortion THD (***) in no-load < 2.5 %
Air flow 50 Hz 0.48 m3/s Total Harmonic Distortion THD (***) in linear load <5%
Air flow 60 Hz 0.58 m3/s Waveform: NEMA = TIF (***) < 50
AREP+/PMG Short-circuit current = 2.7 In: 5 seconds (*) Waveform: I.E.C. = THF (***) < 2%
(*) D350: 10 seconds (**) Steady state (***) Total harmonic distortion between phases, no-load or on-load (non-distorting)
92.6 92.7
93.6 93.5
92 93.0 92 92.8
92.6 92.5
91.4 91.7 91.7
91.3
88 kVA 88 kVA
0 50 100 150 200 250 300 0 50 100 150 200 250 300 350
93.0 92.8
92.4 94.0 94.1 93.7
91.8 91.3 93.5
90 90.8 92
91.9
85 kVA 88 kVA
0 50 100 150 200 250 300 0 100 200 300 400
88 kVA
88 kVA
0 50 100 150 200 250 300 350 0 100 200 300 400 500
C D E F G H C D E F G H
30% 30%
25% 25%
20% 20%
Voltage drop
Voltage drop
15% 15%
10% 10%
5% 5%
0% 0%
0 100 200 300 400 500 600 700 800 900 0 100 200 300 400 500 600 700 800 900 1000
Phase loading (SHUNT) - kVA at P.F. = 0.8 Phase loading (AREP+) - kVA at P.F. = 0.8
C D E F G H C D E F G H
30% 30%
25% 25%
20% 20%
Voltage rise
Voltage rise
15% 15%
10% 10%
5% 5%
0% 0%
0 100 200 300 400 500 0 100 200 300 400 500
Load shedding (SHUNT) - kVA at P.F. = 0.8 Load shedding (AREP+) - kVA at P.F. = 0.8
C D E F G H C D E F G H
30% 30%
25% 25%
20% 20%
Voltage drop
Voltage drop
15% 15%
10% 10%
5% 5%
0% 0%
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800 900
- For a starting P.F. other than 0.6, the starting kVA must be multiplied by K = Sine P.F. / 0.8
- For voltages other than 400V (Y), 230V (Δ) at 50 Hz, then kVA must be multiplied by (400/U)2 or (230/U)2.
- Transient performance of the PMG option, consult us.
85 kVA 85 kVA
0 50 100 150 200 250 300 350 0 100 200 300 400 500
88 kVA 88 kVA
0 100 200 300 400 0 100 200 300 400 500
kVA 88 kVA
85
0 100 200 300 400 0 100 200 300 400 500 600
C D E F G H C D E F G H
30% 30%
25% 25%
20% 20%
Voltage drop
Voltage drop
15% 15%
10% 10%
5% 5%
0% 0%
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200
Phase loading (SHUNT) - kVA at P.F. = 0.8 Phase loading (AREP+) - kVA at P.F. = 0.8
C D E F G H C D E F G H
30% 30%
25% 25%
20% 20%
Voltage rise
Voltage rise
15% 15%
10% 10%
5% 5%
0% 0%
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Load shedding (SHUNT) - kVA at P.F. = 0.8 Load shedding (AREP+) - kVA at P.F. = 0.8
C D E F G H C D E F G H
30% 30%
25% 25%
20% 20%
Voltage drop
Voltage drop
15% 15%
10% 10%
5% 5%
0% 0%
0 200 400 600 800 1000 0 200 400 600 800 1000 1200
- For a starting P.F. other than 0.6, the starting kVA must be multiplied by K = Sine P.F. / 0.8
- For voltages other than 480V (Y), 277V (Δ), 240V (YY) at 60 Hz, then kVA must be multiplied by (480/U)2 or (277/U)2 or (240/U)2.
- Transient performance of the PMG option, consult us.
10000
TAL 046 C
1000 AREP+
Symmetrical --------
In
Asymmetrical - - -
100
SHUNT
Current (A)
10
1
1 10 100 1000 5000
Time (ms)
10000
TAL 046 D
1000 AREP+
Symmetrical --------
In
Asymmetrical - - -
100
SHUNT
Current (A)
10
1
1 10 100 1000 5000
Time (ms)
10000
TAL 046 E
1000 AREP+
Symmetrical -------- In
Asymmetrical - - -
100
SHUNT
Current (A)
10
1
1 10 100 1000 5000
Time (ms)
10000
TAL 046 F
1000 AREP+
Symmetrical -------- In
Asymmetrical - - -
100
SHUNT
Current (A)
10
1
1 10 100 1000 5000
Time (ms)
10000
TAL 046 G
1000 AREP+
Symmetrical -------- In
Asymmetrical - - -
100
SHUNT
Current (A)
10
1
1 10 100 1000 5000
Time (ms)
10000
SHUNT
Current (A)
10
1
1 10 100 1000 5000
Time (ms)
Single-bearing dimensions
L
LB Access to terminals Optional cable
568
AH Xg 506 40 output
ß
198 94.3
CF Standard cable
485.5 (12-wire)
Access to regulator output
PMG optional
421
12 holes Ø S
Ø N - 0.127
- 0.05
Ø BX - 0.15
equid. on Ø M
Ø 235
ØP
0
(option)
280 - 2
0
X holes Ø Y Ø 206
equid. on Ø U
12
355- 02
Option
AIR OUTLET 68 610 21
8 AIR INLET
6 170 737 457
Access to 80 367 80
6 C rotating diodes
Ø 120
Ø 110
Ø 115
Ø 115
Ø 110
Ø 75
Ø 88
Ø 75
Lr
Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm2): (4J = MD2)
Flex plate S.A.E. 11 ½ S.A.E. 14
Type Xr Lr M J Xr Lr M J
TAL 046 C 420 923 255 2.64 408 923 256 2.8
TAL 046 D 420 923 255 2.64 408 923 256 2.8
TAL 046 E 460 968 304 3.28 448 968 305 3.44
TAL 046 F 460 968 304 3.28 448 968 305 3.44
TAL 046 G 508 1063 358 3.97 497 1063 359 4.13
TAL 046 H 508 1063 358 3.97 497 1063 359 4.13
NOTE : Dimensions are for information only and may be subject to modifications. The torsional analysis of the transmission is imperative. All values are available
upon request.
Linkedin.com/company/leroy-somer
Twitter.com/Leroy_Somer_en
Facebook.com/LeroySomer.Nidec.en
YouTube.com/LeroySomerOfficiel
© Nidec 2020. The information contained in this brochure is for guidance only and does not form part of
any contract. The accuracy cannot be guaranteed as Nidec have an ongoing process of development
and reserve the right to change the specification of their products without notice.
Moteurs Leroy-Somer SAS. Siège : Bd Marcellin Leroy, CS 10015, 16915 Angoulême Cedex 9, France.
Capital social : 38 679 664 €, RCS Angoulême 338 567 258.
5675 en - 2021.12 / q