You are on page 1of 156

3003 MEIKARTA BLOCK 56007 - AB MIRROR

ARCHITECTURE WORKS
BILL SUMMARY

Ref Description Amount (IDR)

MEIKARTA BLOCK 56007 - APARTMENT

Summary

BILL 1 - PRELIMINARIES Page : Bill 1/8

BILL 2 - GENERAL Page : Bill 2/3

BILL 3 - APARTMENT Page : Bill 3.11/1

BILL 4 - APARTMENT FAÇADE Page : Bill 4.6/1 13,600,790,013

Bill - Block 56007 - APARTMENT Total


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Ref Description Unit Amount (IDR)

PRELIMINARIES
GENERAL NOTES :-

A The Preliminaries items included herein shall apply


to the whole of the Works as specified and
described in all the Contract Documents and the
rates and prices inserted by the Contractor shall be
deemed to apply to the whole of the Works to be
carried out under the Contract including Provisional
Sum Works.

B The Contractor shall be deemed to have allowed


against clauses in these Preliminaries such rates
and/or prices as are required for Preliminaries
items.

C In the absence of any rates or prices against any


Item or items in these Preliminaries, any monetary
cost attributable thereto shall be deemed to have
been included elsewhere in the Contract
Documents or that no compensation is required in
respect of that item.

D Subject to the terms of the Conditions of Contract,


the documents forming the Contract are to be taken
as mutually explanatory and any rate or price
inserted herein shall be deemed to provide for and
cover the complete and total requirements of each
and every part of the Contract Documents.

E In the event that no rate and/or price is inserted by


the Contractor in respect of any Item or items in
these Preliminaries, no relative payments will be
included in relation thereto in Interim Payment
Certificates, the Final Statement and the Final
Payment Certificate.

F Any rate or price entered in the Preliminaries shall


be at the sole risk of the Contractor and shall be
binding on the Contractor and no adjustment will be
made in the Statement of Final Account and the
Final Certificate other than in accordance with the
requirements of the Conditions of Building Contract.

G The Contractor shall agree with the Engineer /


Quantity Surveyor on a schedule of monthly
payments for Preliminaries items for the duration of
the Contract. The Engineer / Quantity Surveyor
reserves the right to adjust the Preliminaries
payment schedule to reflect actual progress of the
Works against the Construction Programme.
3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Page : Bill 1/1


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Ref Description Unit Amount (IDR)

PRELIMINARIES (Cont'd)
GENERAL NOTES :- (Cont'd)

A Payment for Preliminaries on insurances (if


applicable) and the Performance Security shall be
based on the premiums and service fees paid and
the balance sum priced herein shall be apportioned
based on the Contract duration.

GENERAL

B 1.1 Definitions Item

C 1.2 Brief description of the Works Item

D 1.3 Completion of Sections of the Works Item

E 1.4 Gross areas Item

F 1.5 Access to Site Item

DOCUMENTS

G 2.1 Pricing Documents Item

H 2.2 Discrepancies Item

I 2.3 Guarantees and operating instructions Item

J 2.4 Drawings Item

K 2.5 Shop drawings and co-ordination drawings Item

L 2.6 As-built drawings Item

CONTRACT AND PRICING OF PRELIMINARIES

M 3.1 Pricing Preliminaries Item

N 3.2 Form of Contract Item

O 3.3 Fixed price contract Item

P 3.4 Insurances Item

Q 3.5 Performance Security Item

R 3.6 Date for Commencement Item

S 3.7 Exceptionally adverse weather Item

T 3.8 Working hours and rates of wages Item

U 3.9 Works requiring Employer's site supervision Item

V 3.10 Currency payable Item

W 3.11 Contractor's acceptance of Site conditions Item

X 3.12 Treasure trove Item


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Page : Bill 1/2


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Ref Description Unit Amount (IDR)

PRELIMINARIES (Cont'd)
CONTRACT AND PRICING OF PRELIMINARIES
(Cont'd)

A 3.13 Prime Cost Sum expenditure Item

B 3.14 Provisional Sum expenditure Item

C 3.15 Omission of Provisional Sums Item

D 3.16 Adjustment of Prime Cost rates Item

SUB-CONTRACTORS, SUPPLIERS AND OTHERS


EMPLOYED ON THE WORKS

E 4.1 Forward Contracts Item

F 4.2 Nominated Subcontractors Item

G 4.3 Nominated suppliers Item

H 4.4 Artists, tradesmen and other contractors Item

I 4.5 Installation of Authorities incoming services Item

J 4.6 Contractor's responsibility for all Subcontractors Item


and suppliers

K 4.7 Fix Only Item

L 4.8 Attendance Item

M 4.9 Nominated supply or nominated subcontract Item


work tendered by the Contractor

ADMINISTRATION OF CONTRACT AND WORKS

N 5.1 Illegal foreign workers Item

O 5.2 Contractor's superintendence Item

P 5.3 Workmen to be confined to Site Item

Q 5.4 Trespassing and acts of nuisance Item

R 5.5 Publicity of the Works Item

S 5.6 Public relations measures Item

T 5.7 Resident Engineer Item

U 5.8 Access for the Employer to the Works Item

V 5.9 Access for inspection and testing Item

W 5.10 Welfare and site safety Item

X 5.11 Visitors Item

Y 5.12 Variations and methods of measuring and Item


valuing
3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Page : Bill 1/3


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Ref Description Unit Amount (IDR)

PRELIMINARIES (Cont'd)
ADMINISTRATION OF CONTRACT AND WORKS
(Cont'd)

A 5.13 Payment of Preliminaries Item

B 5.14 Procedures for payment Item

C 5.15 Construction programme Item

D 5.16 Cash flow forecasts Item

E 5.17 Meetings Item

F 5.18 Variation Meetings Item

G 5.19 Progress photographs Item

H 5.20 Photographs of completed development project Item

I 5.21 Progress reports Item

SITE AND WORKS

J 6.1 Setting out of the Works Item

K 6.2 Boundary relationship Item

L 6.3 Progress surveys Item

M 6.4 Final surveys Item

N 6.5 Possession of Site for the Works only Item

O 6.6 Restrict nuisance of dust and noise Item

P 6.7 Interference with traffic and adjoining properties Item

Q 6.8 Extraordinary traffic and special loads Item

R 6.9 Cables/services detection Item

S 6.10 Maintain existing services Item

T 6.11 Response to interruption or disruption to


existing services Item

U 6.12 Maintenance and protection of existing roads Item

V 6.13 Silt control and protection of exposed


excavation surfaces Item

W 6.14 Vector control Item

X 6.15 Damage and theft Item

Y 6.16 Protecting the Works from inclement weather Item

Z 6.17 Site security Item


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Page : Bill 1/4


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Ref Description Unit Amount (IDR)

PRELIMINARIES (Cont'd)
SITE AND WORKS (Cont'd)

A 6.18 Fuel Storage Item

B 6.19 Industry Awards (Not Applicable) Item

C 6.20 Environmental Sustainability Item

D 6.21 Licensing Requirements Item

PLANT AND TEMPORARY WORKS

E 7.1 Offices for Resident Engineer and Resident


Site Staff Item

F 7.2 Temporary access and temporary roads Item

G 7.3 Removal of water and temporary drainage Item

7.4 Shoring and Temporary Works Item


H
7.5 Signs and advertisements Item
I
7.6 Hoardings, fencing and gates Item

J 7.7 Project Name Board Item

K 7.8 Scaffolding and staging Item

L 7.9 Contractor's temporary offices, stores,


workshops Item

M 7.10 Temporary water and electrical services Item

N 7.11 Temporary fire protection services Item

O 7.12 Temporary lightning protection system Item

P 7.13 Temporary telephone service Item

Q 7.14 Plant, tools and vehicles Item

R 7.15 Use of explosive powder tools Item

7.16 Public address system Item


S
7.17 Loading in excess of design load Item
T
7.18 Maintenance of Contractor's Equipment and
U Employer's Equipment Item

V 7.19 Submission of drawings for Temporary Works Item


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Page : Bill 1/5


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Ref Description Unit Amount (IDR)

PRELIMINARIES (Cont'd)
COMPLETION

A 8.1 Occupation Permits Item

B 8.2 Completion and maintenance following


completion Item

C 8.3 Final Payment Claim Item

D 8.4 Removal of rubbish Item

E 8.5 Leave clean on Completion Item

MATERIALS AND WORKMANSHIP

F 9.1 Standards and codes of practice Item

G 9.2 Testing of Materials Item

H 9.3 Materials approval Item

I 9.4 Samples Item

J 9.5 Items specified by name Item

K 9.6 Substitution of materials Item

L 9.7 Storage of materials (including those of Subcontractors Item


and Nominated Direct Contractors)

M 9.8 Transporting materials (including those of Subcontractors Item


and Nominated Direct Contractors)

N 9.9 Labour Item

O 9.10 Protection of completed work Item

P 9.11 Special protection Item

Q 9.12 Site mock-up Item

R 9.13 Prototype Item


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Page : Bill 1/6


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Ref Description Unit Amount (IDR)

PRELIMINARIES (Cont'd)
OTHERS

The Contractor shall provide and allow for any other


items not included in the foregoing but which are
required by the Contract (in particular, the
Specification, the Preliminaries and the Trade
Preambles).

A ……………………………….. Item

B ……………………………….. Item

C ……………………………….. Item

D ……………………………….. Item

E ……………………………….. Item
3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Page : Bill 1/7


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Description Amount (IDR)

BILL NO. 1 PRELIMINARIES

Page : Bill 1/1

Page : Bill 1/2

Page : Bill 1/3

Page : Bill 1/4

Page : Bill 1/5

Page : Bill 1/6

Page : Bill 1/7


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 1 - PRELIMINARIES

Page : Bill 1/8


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 2 - GENERAL

Ref Description Unit Qty

1.0 - GENERAL

A The Contractor is referred to the Preliminaries, Item


Specification and Drawings which form an integral
part of the Contract Documents.

B Subject to the terms of the Conditions of Contract, Item


the Contract Documents are mutually explanatory
and the rates inserted against the items in the Bills
of Quantities shall be deemed to cover the
complete and total requirements of the Contract
Documents.

C The Contract is a fixed price lump sum contract. Item


The Contract Price is not subject to adjustment
due to construction cost escalation, material or
labour price fluctuations. The Contractor is to take
note of the requirements in respect of the fixed
price lump sum and all inclusive pricing nature of
the Contract.

D The Contractor is advised that the Bill of Quantities Item


does not form part of the Contract and has no
contractual effect. The description of any items
herein is not intended to be complete but merely
serves to identify items for interim payments only.
Details of the various items are shown and/or
described in the Contract Documents (including
but not limited to the Drawings and Specification).

E Any other items of work referred to in the Contract Item


Drawings or Specification but not specifically
mentioned herein shall be priced accordingly in the
Bill of Quantities.

F The rates inserted herein shall form the basis for Item
valuing all variations under the Contract. All items
or quantities (as the case may be) stated in the
Bills of Quantities unless otherwise provided, have
been adopted as a basis for measurements
together with the Trade Preambles.

G The rates inserted herein shall be treated as Item


inclusive of all Plant, Materials, work (whether
permanent or temporary) and expenditure, which
are either indispensably necessary to complete the
Works as described in or to be inferred from the
Contract Documents taken as a whole, or which
may contingently become necessary to overcome
difficulties and bring the said Works so described
or inferred to satisfactory completion.
3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 2 - GENERAL

Page : Bill 2/1 To Sub-Colle

Ref Description Unit Qty

1.0 - GENERAL (Cont'd)

A Without prejudice to the above, the Contractor shall Item


be deemed to have included in his rates for all
costs in connection with the Works including but
not limited to all costs for all labour including
overtime costs, Plant, Materials, Goods,
Temporary Works including all fabrication costs;
delivering, unloading, transferring, storing,
returning packaging, handling, hoisting and
lowering; setting, fitting and fixing Materials and
Plant in position; Materials required for lapping,
jointing and the like; conveyance, transportation
and equipment costs; fees, duties and taxes; all
cutting and wastage of Materials; all incidental
Materials such as nails, screws, spikes, plugs,
putty, tow, solder and the like whether or not
specifically mentioned; protection and protection
removal, supervision, attendance; all costs
incidental or ancillary to the provision of any of the
aforesaid; all establishment costs, overheads and
profit.

B The Contractor shall be deemed to have included Item


for all costs in respect of all time delays caused by
workmen, for annual and public holidays, rest
days, travelling time, expenses, fares and
transport, non-productive time and all incentive
and bonus payments, government levies and other
payments mandated by law or which are in
accordance with industry practice and any other
costs, liabilities or disbursements arising from the
employment of labour.

C Unless otherwise stated, all items in the rates Item


specifying Materials, fittings and the like are to be
read as implying that such Materials, fittings and
the like are to be provided and fixed by the
Contractor.

D All Plant and Materials to be used in the Permanent Item


Works shall be new and fixed in position by the
Contractor.

E The Contractor is deemed to have included all cost Item


and/or time implications in compliance with the
above conditions and requirements.
3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 2 - GENERAL

Page : Bill 2/2 To Sub-Colle

Ref Description

1.0 - GENERAL

Sub-Collection

Page : Bill 2/1

Page : Bill 2/2


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 2 - GENERAL

Page : Bill 2/3


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 2 - GENERAL

Rate (IDR) Amount (IDR)

###

###

###

###

###

###
3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 2 - GENERAL

To Sub-Collection To Collection (IDR)

Rate (IDR) Amount (IDR)

###

###

###

###

###
3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 2 - GENERAL

To Sub-Collection To Collection (IDR)

Amount (IDR)
3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 2 - GENERAL

To Summary
3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.1 BRICKWORK AND BLOCKWORK

Autoclaved Aerated Concrete wall; jointing and


pointing in cement mortar including stiffeners, door
lintels, etc.; as specified

Internally

A 75mm Thick wall m2 21,975

B 100mm Thick wall m2 18,993

Page : Bill 3.1/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Total Amount
Ref Description
(IDR)

3.1 - BRICKWORK AND BLOCKWORK

Sub-Collection

Page : Bill 3.1/1

Page : Bill 3.1/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.2 ROOFING

BUILT-UP MEMBRANE ROOFING

Built-up membrane roofing system comprising


cement and sand screed, insulation, waterproofing
membrane and concrete topping

A Roof floor; roof deck, roof LMR, roof dog house m2 1,304

B Roof wall; include upturn 440mm high m2 137

C Wiremesh M6 m2 1,242

Page : Bill 3.2/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Total Amount
Ref Description
(IDR)

3.2 ROOFING

Sub-Collection

Page : Bill 3.2/1

Page : Bill 3.2/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.3 CARPENTRY AND JOINERY

TIMBER DOORS

Timber doors and frames as specified; fixing at


heads and jambs to concrete or blockwork,
including ironmongeries

Single leaf doors

A 950x2050mm to entrance WD-01 No. 736

C 850x2050mm to bedroom WD-02 No. 1,600

D 750x2050mm to toilet WD-03 No. 768

800x2050mm to toilet with washing machine


E No. 128
WD-04

Kitchen top with homogeneous tile finishes including


accessories as specified in the Drawings

F Overall size 1200x600mm No. 736


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Page : Bill 3.3/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Total Amount
Ref Description
(IDR)

3.3 CARPENTRY AND JOINERY

Sub-Collection

Page : Bill 3.3/1

Page : Bill 3.3/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.4 METAL WORKS

BALUSTRADES

Balustrades 1050mm high; 50mm diameter steel


pipe top, 20x40 flat tube intermediate and bottom rails
with vertical posts and rails; 16x16mm square tube
vertical posts; sprayed with oil paint; fixing to
concrete; as specified in the Drawing

A Balustrades; to staircase m 751

B Balustrades; to staircase roof deck to LMR m 9

RAILING

Railing 1100mm high; as specified in the Drawings

C Railing; to balcony m 1,344

D Railing; to LMR m 12

Railing 220mm high; as specified in the Drawings

E Railing; to balcony m 128

FIRE-RATED DOORS

Fire rated steel doors and frames; fixing at heads


and jambs to concrete or blockwork; including
ironmongeries, as specified

Single leaf doors

F Doors and frames to suit opening 900x2050mm No. 128


(Type FD-01) to staircase; typical

G Doors and frames to suit opening 1000x2050mm No. 64


(Type FD-02) to fire lift lobby; typical

Doors and frames to suit opening 600x1200mm


H No. 160
(Type FD-05) to shaft door; typical

Doors and frames to suit opening 700x2050mm


I No. 128
(Type FD-10) to bin room; typical

J Doors and frames to suit opening 900x2050mm No. 5


(Type FD-01) to LMR roof deck

Double leaf doors

Doors and frames to suit opening 900x1900mm


K No. 128
(Type FD-04) to typical shaft door

Doors and frames to suit opening 1700x2050mm


L No. 64
(Type FD-11) to smoke free lobby

SUNDRIES

Allow for room signage

M Room signage No. 736

Page : Bill 3.4/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Total Amount
Ref Description
(IDR)

3.4 METAL WORKS

Sub-Collection

Page : Bill 3.4/1

Page : Bill 3.4/4 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.5 WALL CEILING FINISHINGS

IN-SITU FINISHES

Cement and sand plaster; as specified

Internally

To wall; 15mm thick to corridor, lift lobby and


A m2 6,710
smoke free lobby

B To wall; 15mm thick to bathroom m2 11,584

C To wall; staircase m2 1,724

D To wall; roof deck and LMR m2 145

Skimcoat

Internally

F To wall; corridor, smoke free lobby m2 7,612

G To wall unit; bedroom & living room m2 9,124

H To ceiling; living room, bedroom m2 2,850

I To ceiling; smoke free lobby and stair lobby m2 524

J To wall and sloping soffits of staircase m2 6,558

K To wall; roof deck and LMR m2 71

Externally

L To ceiling; balcony & AC out m2 1,740

M To ceiling; canopy LMR m2 6

Gypsum

N 9mm thick stick on wall: bedroom & living room m2 59,773

O To ceiling unit; bedroom & living room m2 16,495

P To ceiling; corridor and lift lobby m2 2,621

Q To ceiling; drop ceiling h450 m2 5,887

Gypsum Water Resistant

R To ceiling; bathroom m2 2,573

Stainless steel door jamb lift

S Stainless steel door jamb lift m2 389

Grooveline

T 10mm thick grooveline to bathroom and wastafel m 3,136

Page : Bill 3.5/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.5 WALL CEILING FINISHINGS (CONT'D)

WATERPROOFING SYSTEM

1.5mm thick JS waterproof layer; applied strictly in


accordance with manufacturer's instruction; as
specified in the Drawing

A To wall; bathroom m2 7,936

B To wall; kitchen backsplash m2 1,345

CERAMIC TILE FINISHES

Supply and install ceramic tiles; include cement and


sand backing on waterproof base (measured separately)
as specified

C 400x400mm to walls; Type CT-04 to bathroom m2 7,936

Page : Bill 3.5/2 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

All-in Unit Rate Total Amount


Ref Description
(IDR) (IDR)

3.5 WALL CEILING FINISHING

Page : Bill 3.5/1

Page : Bill 3.5/2

Page : Bill 3.5/3 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.6 FLOOR FINISHINGS

IN-SITU FINISHES

Cement and sand screed in steel trowelled smooth


finish; as specified

A To AC out m2 518

B To staircase m2 1,990

C To smoke free lobby m2 510

WATERPROOFING SYSTEM

E To bathroom m2 2,426

F To balcony m2 1,442

G To kitchen m2 671

H To AC out m2 518

I To canopy LMR m2 6

J Fiber mesh sika top - 107 seal to F1 m2 104

K Waterproof sika lastic 311 AE to F1 m2 112

CERAMIC TILE FINISHES

Supply and install ceramic tiles; including screeded


bed on structure or waterproof base (measured
separately) and pointing with matching colour
cement grout; as specified

L 400x400mm ceramic tiles to floors; Type CT-02 m2 1,442


to balcony

M 400x400mm ceramic tiles to floors; Type CT-03 m2 2,354


to bathroom

N 400x400mm ceramic tiles to floors; Type CT-11 m2 10,907


to bedroom

O 100x400mm Threshold; Type CT-05 to bathroom m 725

P 100x400mm Threshold; Type CT-07 to bedroom m 3,597

Q 100x400mm Step nosing to landing and treads m 2,343

R 100mm high to skirting at corridor and lift lobby m 2,908

S 100mm high to skirting at balcony m 3,689

Page : Bill 3.6/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.6 FLOOR FINISHINGS (CONT'D)

HOMOGENEOUS TILE FINISHES

Supply and install homogeneous tiles; including screeded


bed on structure or waterproof base (measured
separately) and pointing with matching colour
cement grout; as specified

A 600x600mm homogeneous tiles to floors; Type C m2 14,036


to living room/ bedroom, pantry

B 600x600mm homogeneous tiles to floors; Type C m2 2,626


to corridor and lift lobby

PVC FINISHES

C 60mm high to skirting at bedroom, living room m 28,757

FLOOR HARDENER

D To smoke free lobby m2 510

E To staircase m2 1,990

Page : Bill 3.6/2 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

All-in Unit Rate Total Amount


Ref Description
(IDR) (IDR)

3.6 FLOOR FINISHING

Sub-Collection

Page : Bill 3.6/1

Page : Bill 3.6/2

Page : Bill 3.6/3 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.7 WATER PIPING AND SANITARY


PLUMBING SYSTEM

SANITARY WARE, FITTINGS & TOILET


ACCESSORIES

Supply and delivery of the following sanitary ware,


fittings and toilet accessories or approved equivalent
including all accessories and brackets

A Water Closet (WC); Type S-Trap No. 768

B Water Closet (WC); Type P-Trap No. 128

C Mixer; KW 05 No. 896

D Hand Shower; S-04 No. 896

E Faucet (Cold Only); KW 03 No. 800

F Floor Drain Ø 2" No. 1,664

G Washing Machine Faucet No. 640

H Jet Washer; Kranz S-01 No. 896

I Kitchen sink faucet KD08 1/2" No. 736

J Wastafel; Oulu W240 (Provisional) No. 320

K Wastafel; Oulu W288 ( Provisional) No. 480


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Page : Bill 3.7/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Total Amount
Ref Description
(IDR)

3.7 WATER PIPING AND SANITARY


PLUMBING SYSTEM

Sub-Collection

Page : Bill 3.7/1

Page : Bill 3.7/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.8 GLAZING

MIRROR

Mirror to toilet; including all necessary backing and


frame

A Overall size 400x500mm No. 32

B Overall size 600x550mm No. 288

C Overall size 600x600mm No. 512


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Page : Bill 3.8/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

All-in Unit Rate Total Amount


Ref Description
(IDR) (IDR)

3.8 GLAZING

Sub-Collection

Page : Bill 3.8/1

Page : Bill 3.8/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.9 PAINTING, POLISHING AND OTHER


SIMILAR WORK

EMULSION PAINT

Apply one coat of primer and two coat of white


emulsion paint; as specified in the Drawing and
Specification

A To walls; to living room, bedroom, pantry m2 68,897

B To walls; to bathroom m2 4,064

C To walls; to corridor, smoke free lobby m2 7,612

D To ceiling; to living room, bedroom, pantry m2 25,232

E To ceiling; to bathroom m2 2,573

F To ceiling; to corridor, lift lobby m2 2,621

G To wall and sloping soffits; staircase m2 6,558

H To wall; roof deck and LMR m2 71

WEATHERSHIELD PAINT

I To ceiling; balcony and AC out m2 1,740

J To ceiling; canopy LMR m2 6

Page : Bill 3.9/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

All-in Unit Rate Total Amount


Ref Description
(IDR) (IDR)

3.9 PAINTING, POLISHING AND OTHER SIMILAR WORK

Sub-Collection

Page : Bill 3.9/1

Page : Bill 3.9/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

3.10 OTHERS

Allow herein for any other work not mentioned above but
specified and/or shown in the Specification and/or
Drawings which are considered necessary for the full
and satisfactory completion for the works.
The Contractor is to list out the items below and indicate
the cost breakdown against each item

Page : Bill 3.10/1 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

All-in Unit Rate Total Amount


Ref Description
(IDR) (IDR)

3.10 OTHERS

Sub-Collection

Page : Bill 3.10/1

Page : Bill 3.10/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 3 - APARTMENT ARCHITECTURE WORKS

Total Amount
Ref Description
(IDR)

BILL 3.0 - APARTMENT

Collection

Page : Bill 3.1/2 BRICKWORK AND BLOCKWORK

Page : Bill 3.2/2 ROOFING

Page : Bill 3.3/2 CARPENTRY AND JOINERY

Page : Bill 3.4/5 METAL WORKS

Page : Bill 3.5/3 WALL CEILING FINISHINGS

Page : Bill 3.6/3 FLOOR FINISHINGS

Page : Bill 3.7/2 WATER PIPING AND SANITARY

Page : Bill 3.8/2 GLAZING

Page : Bill 3.9/2 PAINTING, POLISHING AND OTHER

Page : Bill 3.10/2 OTHERS

Page : Bill 3.11/1 To Summary


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4.1 BRICKWORK AND BLOCKWORK

Autoclaved Aerated Concrete wall; jointing and


pointing in cement mortar including stiffeners, door
lintels, etc.; as specified

Externally

A 75mm Thick wall m2 3,786

B 100mm Thick wall m2 4,336

C 150mm Thick wall (Provisional) m2 9,324

D 100mm Thick wall to LMR m2 361

E 100mm Thick wall to dog house m2 40

Concrete

F 140mm high reinforced concrete sill to window m 5,266

G 100mm Thick reinforced concrete wall to crown m3 41

H 150mm Thick reinforced concrete parapet m3 4


to LMR roof

Page : Bill 4.1/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Total Amount
Ref Description
(IDR)

4.1 - BRICKWORK AND BLOCKWORK

Sub-Collection

Page : Bill 4.1/1

Page : Bill 4.1/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4.2 METAL WORKS

ALUMINIUM DOORS

Glass doors and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as specified

External Doors

Single leaf doors

A Doors and frames to suit opening 850x2100mm No. 160


(Type TM0821); to washing machine room

B Doors and frames to suit opening 1300x2100mm No. 192


(Type MLC1321) including window

Sliding Doors

C Sliding doors and frames to balcony 1200x2200mm No. 128


(Type TM1221); to balcony

D Sliding doors and frames to balcony 1600x2100mm No. 320


(Type TM1621); to balcony

Page : Bill 4.2/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4.2 METAL WORKS (CONT'D)

ALUMINIUM WINDOW

Glass windows and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as specified

A Overall size 500x1200mm (Type C0512A) No. 32

B Overall size 600x1200mm (Type C0612) No. 64

C Overall size 600x1200mm (Type C0612A) No. 192

D Overall size 600x1200mm (Type C0612B) No. 32

E Overall size 780x1200mm (Type C0712A) No. 32

F Overall size 785x1200mm (Type C0712B) No. 160

G Overall size 705x1200mm (Type C0712C) No. 64

H Overall size 800x1200mm (Type C0812) No. 32

I Overall size 800x1200mm (Type C0812A) No. 256

J Overall size 1000x1200mm (Type C1012) No. 64

K Overall size 1000x1200mm (Type C1012') No. 32

L Overall size 1050x1200mm (Type C1012B') No. 32

M Overall size 1260x1200mm (Type C1212C') No. 32

N Overall size 1300x1200mm (Type C1312') No. 32

O Overall size 1335x1200mm (Type C1312A) No. 64

P Overall size 1360x1200mm (Type C1312B) No. 32

Q Overall size 1360x1200mm (Type C1312B') No. 32

R Overall size 1360x1200mm (Type C1312C) No. 32

S Overall size 1360x1200mm (Type C1312C') No. 32

T Overall size 1380x1200mm (Type C1312F) No. 32

U Overall size 1430x1200mm (Type C1412B) No. 32

V Overall size 1430x1200mm (Type C1412B') No. 32

W Overall size 1560x1200mm (Type C1512B) No. 64

X Overall size 1530x1200mm (Type C1512C) No. 32

Y Overall size 1600x1200mm (Type C1612') No. 32

Z Overall size 1670x1200mm (Type C1612A) No. 32

Page : Bill 4.2/2 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4.2 METAL WORKS (CONT'D)

ALUMINIUM WINDOW (CONT'D)

Glass windows and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as
specified (Cont'd)

A Overall size 1670x1200mm (Type C1612A') No. 32

B Overall size 1670x1200mm (Type C1612B') No. 32

C Overall size 1780x1200mm (Type C1712') No. 64

D Overall size 1700x1200mm (Type C1712A') No. 32

E Overall size 1850x1200mm (Type C1812') No. 32

F Overall size 1800x1200mm (Type C1812C') No. 32

G Overall size 1935x1200mm (Type C1912') No. 32

H Overall size 2040x1200mm (Type C2012A') No. 32

I Overall size 2040x1200mm (Type C2012C) No. 32

J Overall size 2100x1200mm (Type C2112') No. 64

K Overall size 2150x1200mm (Type C2112A) No. 32

L Overall size 2150x1200mm (Type C2112A') No. 32

M Overall size 2130x1200mm (Type C2112E') No. 32

N Overall size 2210x1200mm (Type C2212') No. 64

O Overall size 2230x1200mm (Type C2212B') No. 32

P Overall size 2300x1200mm (Type C2312A) No. 32

Q Overall size 2300x1200mm (Type C2312A') No. 32

R Overall size 2380x1200mm (Type C2312B) No. 32

S Overall size 2360x1200mm (Type C2312C) No. 32

T Overall size 2400x1200mm (Type C2412) No. 32

U Overall size 2420x1200mm (Type C2412B) No. 64

V Overall size 2420x1200mm (Type C2412B') No. 32

W Overall size 2485x1200mm (Type C2412C) No. 32

X Overall size 2580x1200mm (Type C2512A) No. 64

Y Overall size 2500x1200mm (Type C2512B) No. 64

Z Overall size 2700x1200mm (Type C2712A') No. 32

Z Overall size 2765x1200mm (Type C2712B) No. 64

Page : Bill 4.2/3 To Sub-Collection

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4.2 METAL WORKS (CONT'D)


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

ALUMINIUM WINDOW (CONT'D)

Glass windows and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as
specified (Cont'd)

A Overall size 3040x1200mm (Type C3012A) No. 32

B Overall size 3095x1200mm (Type C3012B') No. 32

Page : Bill 4.2/4 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Total Amount
Ref Description
(IDR)

4.2 METAL WORKS

Sub-Collection

Page : Bill 4.2/1

Page : Bill 4.2/2

Page : Bill 4.2/4

Page : Bill 4.2/5 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4.3 WALL CEILING FINISHINGS

IN-SITU FINISHES

Cement and sand plaster; as specified

Externally

A To wall; to concrete surface m2 9,778

B To wall; to AAC surface m2 20,253

C 0.8mm dia galvanized to external wall m2 29,632


finishing layer

D To wall; 18mm to roof deck, dog house and LMR m2 335

Skimcoat

Externally

E To wall and column ; roof deck, dog house and LMR m2 1,284

F To beam; 20mm thick to crown m2 1,348

WATERPROOFING SYSTEM

1.5mm thick JS waterproof layer; applied strictly in


accordance with manufacturer's instruction; as
specified in the Drawing

G To wall; balcony m2 458

Page : Bill 4.3/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Total Amount
Ref Description
(IDR)

4.3 WALL CEILING FINISHING

Page : Bill 4.3/1

Page : Bill 4.3/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4.4 PAINTING, POLISHING AND OTHER


SIMILAR WORK

WEATHERSHIELD PAINT

A To wall: unit outside; Type SK Sipokaken (ex. SKK) m2 7,957

B To wall: unit outside; Type CK Ceraskaken (ex. SKK) m2 5,306

C To wall: unit outside; SL Super Lenaflex (ex. SKK)- non texture m2 16,369

D To Pipe: unit outside m 1,261

F To beam: crown; Type CK Ceraskaken (ex. SKK) m2 526

To wall; roof deck, dog house and LMR; SL Super Lenaflex (ex.
H m2 335
SKK)- non texture

I To parapet wall; Type SK Sipokaken (ex. SKK) m2 136

J To parapet wall; Type CK Ceraskaken (ex. SKK) m2 210

K To parapet wall: ; SL Super Lenaflex (ex. SKK)- non texture m2 306

Page : Bill 4.4/1 To Sub-Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

All-in Unit Rate Total Amount


Ref Description
(IDR) (IDR)

4.4 PAINTING, POLISHING AND OTHER SIMILAR WORK

Sub-Collection

Page : Bill 4.4/1

Page : Bill 4.4/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Supply Rate Install Rate All-in Unit Rate Total Amount


Ref Description Unit Qty Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4.5 OTHERS

Allow herein for any other work not mentioned above but
specified and/or shown in the Specification and/or
Drawings which are considered necessary for the full
and satisfactory completion for the works.
The Contractor is to list out the items below and indicate
the cost breakdown against each item

Page : Bill 4.5/1 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

All-in Unit Rate Total Amount


Ref Description
(IDR) (IDR)

4.5 OTHERS

Sub-Collection

Page : Bill 4.5/1

Page : Bill 4.5/2 To Collection


3003 MEIKARTA BLOCK 56007 - AB MIRROR
ARCHITECTURE WORKS
BILL 4 - APARTMENT FACADE

Total Amount
Ref Description
(IDR)

BILL 4.0 - APARTMENT FAÇADE

Collection

Page : Bill 4.1/2 BRICKWORK AND BLOCKWORK

Page : Bill 4.2/5 METAL WORKS

Page : Bill 4.3/3 WALL CEILING FINISHINGS

Page : Bill 4.4/2 PAINTING, POLISHING AND OTHER

Page : Bill 4.5/2 OTHERS

Page : Bill 4.6/1 To Summary


Ref Description Unit Qty

4.1 BRICKWORK AND BLOCKWORK

Autoclaved Aerated Concrete wall; jointing and


pointing in cement mortar including stiffeners, door
lintels, etc.; as specified

Externally

75ew A 75mm Thick wall m2 3,786

B 100mm Thick wall m2 4,336

100ew C 150mm Thick wall (Provisional) m2 9,324

D 100mm Thick wall to LMR m2 361

E 100mm Thick wall to dog house m2 40

Concrete

csw F 140mm high reinforced concrete sill to window m 5,266

G 100mm Thick reinforced concrete wall to crown m3 41

H 150mm Thick reinforced concrete parapet m3 4


to LMR roof
Page : Bill 4.1/1

Ref Description

4.1 - BRICKWORK AND BLOCKWORK

Sub-Collection

Page : Bill 4.1/1


Page : Bill 4.1/2

Ref Description Unit Qty

4.2 METAL WORKS

ALUMINIUM DOORS

Glass doors and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as specified

External Doors

Single leaf doors

tm0821 A Doors and frames to suit opening 850x2100mm No. 160


(Type TM0821); to washing machine room

mlc1322 B Doors and frames to suit opening 1300x2100mm No. 192


(Type MLC1321) including window

Sliding Doors

tm1222 C Sliding doors and frames to balcony 1200x2200mm No. 128


(Type TM1221); to balcony

tm1621 D Sliding doors and frames to balcony 1600x2100mm No. 320


(Type TM1621); to balcony
Page : Bill 4.2/1 800

Ref Description Unit Qty

4.2 METAL WORKS (CONT'D)

ALUMINIUM WINDOW

Glass windows and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as specified

C0506 A Overall size 500x1200mm (Type C0512A) No. 32

C0512B B Overall size 600x1200mm (Type C0612) No. 64


C0606 C Overall size 600x1200mm (Type C0612A) No. 192

C0612 D Overall size 600x1200mm (Type C0612B) No. 32

C0612A E Overall size 780x1200mm (Type C0712A) No. 32

C0712A F Overall size 785x1200mm (Type C0712B) No. 160

C0712B G Overall size 705x1200mm (Type C0712C) No. 64

C0712C H Overall size 800x1200mm (Type C0812) No. 32

C0712D I Overall size 800x1200mm (Type C0812A) No. 256

C0806 J Overall size 1000x1200mm (Type C1012) No. 64

C0812 K Overall size 1000x1200mm (Type C1012') No. 32

C0812A L Overall size 1050x1200mm (Type C1012B') No. 32

C0912B' M Overall size 1260x1200mm (Type C1212C') No. 32

C1012A N Overall size 1300x1200mm (Type C1312') No. 32

C1012B O Overall size 1335x1200mm (Type C1312A) No. 64

C1112 P Overall size 1360x1200mm (Type C1312B) No. 32

C1212D Q Overall size 1360x1200mm (Type C1312B') No. 32

C1212D' R Overall size 1360x1200mm (Type C1312C) No. 32

C1312' S Overall size 1360x1200mm (Type C1312C') No. 32

C1312F T Overall size 1380x1200mm (Type C1312F) No. 32

C1312F' U Overall size 1430x1200mm (Type C1412B) No. 32

C1412' V Overall size 1430x1200mm (Type C1412B') No. 32

C1412B W Overall size 1560x1200mm (Type C1512B) No. 64


C1412B' X Overall size 1530x1200mm (Type C1512C) No. 32

C1512C Y Overall size 1600x1200mm (Type C1612') No. 32

C1612' Z Overall size 1670x1200mm (Type C1612A) No. 32

Page : Bill 4.2/2 1,504

Ref Description Unit Qty

4.2 METAL WORKS (CONT'D)

ALUMINIUM WINDOW (CONT'D)

Glass windows and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as
specified (Cont'd)

C1612A' A Overall size 1670x1200mm (Type C1612A') No. 32

C1612B' B Overall size 1670x1200mm (Type C1612B') No. 32

C1712' C Overall size 1780x1200mm (Type C1712') No. 64

C1712A' D Overall size 1700x1200mm (Type C1712A') No. 32

C1812' E Overall size 1850x1200mm (Type C1812') No. 32

C1812C' F Overall size 1800x1200mm (Type C1812C') No. 32

C1912' G Overall size 1935x1200mm (Type C1912') No. 32

C2012A' H Overall size 2040x1200mm (Type C2012A') No. 32

C2012C I Overall size 2040x1200mm (Type C2012C) No. 32

C2112' J Overall size 2100x1200mm (Type C2112') No. 64

C2112A K Overall size 2150x1200mm (Type C2112A) No. 32


C2112A' L Overall size 2150x1200mm (Type C2112A') No. 32

C2112E' M Overall size 2130x1200mm (Type C2112E') No. 32

C2212' N Overall size 2210x1200mm (Type C2212') No. 64

C2212B' O Overall size 2230x1200mm (Type C2212B') No. 32

C2312A P Overall size 2300x1200mm (Type C2312A) No. 32

C2312A' Q Overall size 2300x1200mm (Type C2312A') No. 32

C2312B R Overall size 2380x1200mm (Type C2312B) No. 32

C2312C S Overall size 2360x1200mm (Type C2312C) No. 32

C2412 T Overall size 2400x1200mm (Type C2412) No. 32

C2412B U Overall size 2420x1200mm (Type C2412B) No. 64

C2412B' V Overall size 2420x1200mm (Type C2412B') No. 32

C2412C W Overall size 2485x1200mm (Type C2412C) No. 32

C2512A X Overall size 2580x1200mm (Type C2512A) No. 64

C2512B Y Overall size 2500x1200mm (Type C2512B) No. 64

C2712A' Z Overall size 2700x1200mm (Type C2712A') No. 32

C2712B Z Overall size 2765x1200mm (Type C2712B) No. 64

Page : Bill 4.2/3 1,088

Ref Description Unit Qty

4.2 METAL WORKS (CONT'D)

ALUMINIUM WINDOW (CONT'D)

Glass windows and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as
specified (Cont'd)

C3012A A Overall size 3040x1200mm (Type C3012A) No. 32

C3012B' B Overall size 3095x1200mm (Type C3012B') No. 32


Page : Bill 4.2/4 64

Ref Description

4.2 METAL WORKS

Sub-Collection

Page : Bill 4.2/1

Page : Bill 4.2/2

Page : Bill 4.2/3

Page : Bill 4.2/4


Page : Bill 4.2/5

Ref Description Unit Qty

4.3 WALL CEILING FINISHINGS

IN-SITU FINISHES

Cement and sand plaster; as specified

Externally

plwext A To wall; to concrete surface m2 9,778

plw B To wall; to AAC surface m2 20,253

C 0.8mm dia galvanized to external wall m2 29,632


finishing layer

D To wall; 18mm to roof deck, dog house and LMR m2 335

Skimcoat

Externally

E To wall and column ; roof deck, dog house and LMR m2 1,284

F To beam; 20mm thick to crown m2 1,348

WATERPROOFING SYSTEM

1.5mm thick JS waterproof layer; applied strictly in


accordance with manufacturer's instruction; as
specified in the Drawing

wp G To wall; balcony m2 458


Page : Bill 4.3/1

Ref Description

4.3 WALL CEILING FINISHING

Page : Bill 4.3/1


Page : Bill 4.3/2

Ref Description Unit Qty

4.4 PAINTING, POLISHING AND OTHER


SIMILAR WORK

WEATHERSHIELD PAINT

M104 A To wall: unit outside; Type SK Sipokaken (ex. SKK) m2 7,957

M105 B To wall: unit outside; Type CK Ceraskaken (ex. SKK) m2 5,306

M106 C To wall: unit outside; SL Super Lenaflex (ex. SKK)- non texture m2 16,369

D To Pipe: unit outside m 1,261

F To beam: crown; Type CK Ceraskaken (ex. SKK) m2 526

To wall; roof deck, dog house and LMR; SL Super Lenaflex (ex.
H m2 335
SKK)- non texture

I To parapet wall; Type SK Sipokaken (ex. SKK) m2 136

J To parapet wall; Type CK Ceraskaken (ex. SKK) m2 210

K To parapet wall: ; SL Super Lenaflex (ex. SKK)- non texture m2 306


Page : Bill 4.4/1

Ref Description

4.4 PAINTING, POLISHING AND OTHER SIMILAR WORK

Sub-Collection

Page : Bill 4.4/1


Page : Bill 4.4/2

Ref Description Unit Qty

4.5 OTHERS

Allow herein for any other work not mentioned above but
specified and/or shown in the Specification and/or
Drawings which are considered necessary for the full
and satisfactory completion for the works.
The Contractor is to list out the items below and indicate
the cost breakdown against each item

C
Page : Bill 4.5/1

Ref Description

4.5 OTHERS

Sub-Collection

Page : Bill 4.5/1


Page : Bill 4.5/2

Ref Description

BILL 4.0 - APARTMENT FAÇADE

Collection

Page : Bill 4.1/2 BRICKWORK AND BLOCKWORK

Page : Bill 4.2/5 METAL WORKS

Page : Bill 4.3/3 WALL CEILING FINISHINGS

Page : Bill 4.4/2 PAINTING, POLISHING AND OTHER

Page : Bill 4.5/2 OTHERS


Page : Bill 4.6/1
Supply Rate Install Rate All-in Unit Rate Total Amount
Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
To Sub-Collection
Total Amount
(IDR)
To Collection

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4,284,909 702,167 4,987,076 797,932,093

5,772,066 918,520 6,690,587 1,284,592,632

6,187,605 1,038,499 7,226,103 924,941,195

6,508,829 1,321,725 7,830,554 2,505,777,305


To Sub-Collection 5,513,243,225

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

1,513,186 236,022 1,749,209 55,974,677

1,580,352 283,227 1,863,579 119,269,077


1,614,340 283,227 1,897,567 364,332,779

1,580,352 283,227 1,863,579 59,634,539

1,755,178 368,195 2,123,373 67,947,935

1,734,302 370,555 2,104,857 336,777,074

1,690,359 332,792 2,023,150 129,481,624

1,772,463 377,636 2,150,099 68,803,167

1,772,463 377,636 2,150,099 550,425,339

1,945,314 472,045 2,417,359 154,710,989

1,913,215 472,045 2,385,260 76,328,325

1,988,527 495,647 2,484,174 79,493,576

2,104,363 594,776 2,699,139 86,372,455

2,129,467 613,658 2,743,125 87,780,006

2,151,433 630,180 2,781,613 178,023,226

2,167,123 641,981 2,809,104 89,891,332

2,167,123 641,981 2,809,104 89,891,332

2,167,123 641,981 2,809,104 89,891,332

2,167,123 641,981 2,809,104 89,891,332

2,179,675 651,422 2,831,097 90,595,108

2,211,056 675,024 2,886,080 92,354,547

2,211,056 675,024 2,886,080 92,354,547

2,292,644 736,390 3,029,034 193,858,176


2,273,816 722,229 2,996,045 95,873,425

2,317,748 755,272 3,073,020 98,336,639

2,361,681 788,315 3,149,995 100,799,854

To Sub-Collection 3,539,092,414

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

2,361,681 788,315 3,149,995 100,799,854

2,361,681 788,315 3,149,995 100,799,854

2,576,227 840,240 3,416,466 218,653,839

2,380,509 802,476 3,182,985 101,855,517

2,620,159 873,283 3,493,442 111,790,134

2,588,779 849,681 3,438,459 110,030,695

2,673,505 913,407 3,586,912 114,781,180

2,739,404 962,971 3,702,375 118,476,002

2,804,886 962,971 3,767,857 120,571,428

2,777,060 991,294 3,768,354 241,174,657

2,808,440 1,014,896 3,823,336 122,346,767


2,808,440 1,014,896 3,823,336 122,346,767

2,795,888 1,005,455 3,801,343 121,642,992

2,846,096 1,043,219 3,889,315 248,916,188

2,858,649 1,052,660 3,911,308 125,161,870

2,902,581 1,085,703 3,988,284 127,625,084

2,902,581 1,085,703 3,988,284 127,625,084

2,952,789 1,123,467 4,076,256 130,440,186

2,940,237 1,114,026 4,054,263 129,736,411

2,965,341 1,132,907 4,098,249 131,143,962

2,977,893 1,142,348 4,120,242 263,695,475

2,977,893 1,142,348 4,120,242 131,847,738

3,018,688 1,173,031 4,191,719 134,135,008

3,078,310 1,217,876 4,296,186 274,955,884

3,028,102 1,180,112 4,208,214 269,325,680

3,153,623 1,274,521 4,428,144 141,700,595

3,194,417 1,305,204 4,499,621 287,975,732

To Sub-Collection 4,229,554,582

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
3,517,553 1,435,016 4,952,569 158,482,205

3,552,071 1,460,979 5,013,050 160,417,588


To Sub-Collection 318,899,792
Total Amount
(IDR)

5,513,243,225

3,539,092,414

4,229,554,582

318,899,792
To Collection 13,600,790,013

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
To Sub-Collection
Total Amount
(IDR)
To Collection

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
To Sub-Collection

All-in Unit Rate Total Amount


(IDR) (IDR)
To Collection

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
To Collection

All-in Unit Rate Total Amount


(IDR) (IDR)
To Collection
Total Amount
(IDR)

13,600,790,013
To Summary 13,600,790,013
Ref Description Unit Qty

4.1 BRICKWORK AND BLOCKWORK

Autoclaved Aerated Concrete wall; jointing and


pointing in cement mortar including stiffeners, door
lintels, etc.; as specified

Externally

75ew A 75mm Thick wall m2 3,786

B 100mm Thick wall m2 4,336

100ew C 150mm Thick wall (Provisional) m2 9,324

D 100mm Thick wall to LMR m2 361

E 100mm Thick wall to dog house m2 40

Concrete

csw F 140mm high reinforced concrete sill to window m 5,266

G 100mm Thick reinforced concrete wall to crown m3 41

H 150mm Thick reinforced concrete parapet m3 4


to LMR roof
Page : Bill 4.1/1

Ref Description

4.1 - BRICKWORK AND BLOCKWORK

Sub-Collection

Page : Bill 4.1/1


Page : Bill 4.1/2

Ref Description Unit Qty

4.2 METAL WORKS

ALUMINIUM DOORS

Glass doors and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as specified

External Doors

Single leaf doors

tm0821 A Doors and frames to suit opening 850x2100mm No. 160


(Type TM0821); to washing machine room

mlc1322 B Doors and frames to suit opening 1300x2100mm No. 192


(Type MLC1321) including window

Sliding Doors

tm1222 C Sliding doors and frames to balcony 1200x2200mm No. 128


(Type TM1221); to balcony

tm1621 D Sliding doors and frames to balcony 1600x2100mm No. 320


(Type TM1621); to balcony
Page : Bill 4.2/1 800

Ref Description Unit Qty

4.2 METAL WORKS (CONT'D)

ALUMINIUM WINDOW

Glass windows and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as specified

C0506 A Overall size 500x1200mm (Type C0512A) No. 32

C0512B B Overall size 600x1200mm (Type C0612) No. 64


C0606 C Overall size 600x1200mm (Type C0612A) No. 192

C0612 D Overall size 600x1200mm (Type C0612B) No. 32

C0612A E Overall size 780x1200mm (Type C0712A) No. 32

C0712A F Overall size 785x1200mm (Type C0712B) No. 160

C0712B G Overall size 705x1200mm (Type C0712C) No. 64

C0712C H Overall size 800x1200mm (Type C0812) No. 32

C0712D I Overall size 800x1200mm (Type C0812A) No. 256

C0806 J Overall size 1000x1200mm (Type C1012) No. 64

C0812 K Overall size 1000x1200mm (Type C1012') No. 32

C0812A L Overall size 1050x1200mm (Type C1012B') No. 32

C0912B' M Overall size 1260x1200mm (Type C1212C') No. 32

C1012A N Overall size 1300x1200mm (Type C1312') No. 32

C1012B O Overall size 1335x1200mm (Type C1312A) No. 64

C1112 P Overall size 1360x1200mm (Type C1312B) No. 32

C1212D Q Overall size 1360x1200mm (Type C1312B') No. 32

C1212D' R Overall size 1360x1200mm (Type C1312C) No. 32

C1312' S Overall size 1360x1200mm (Type C1312C') No. 32

C1312F T Overall size 1380x1200mm (Type C1312F) No. 32

C1312F' U Overall size 1430x1200mm (Type C1412B) No. 32

C1412' V Overall size 1430x1200mm (Type C1412B') No. 32

C1412B W Overall size 1560x1200mm (Type C1512B) No. 64


C1412B' X Overall size 1530x1200mm (Type C1512C) No. 32

C1512C Y Overall size 1600x1200mm (Type C1612') No. 32

C1612' Z Overall size 1670x1200mm (Type C1612A) No. 32

Page : Bill 4.2/2 1,504

Ref Description Unit Qty

4.2 METAL WORKS (CONT'D)

ALUMINIUM WINDOW (CONT'D)

Glass windows and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as
specified (Cont'd)

C1612A' A Overall size 1670x1200mm (Type C1612A') No. 32

C1612B' B Overall size 1670x1200mm (Type C1612B') No. 32

C1712' C Overall size 1780x1200mm (Type C1712') No. 64

C1712A' D Overall size 1700x1200mm (Type C1712A') No. 32

C1812' E Overall size 1850x1200mm (Type C1812') No. 32

C1812C' F Overall size 1800x1200mm (Type C1812C') No. 32

C1912' G Overall size 1935x1200mm (Type C1912') No. 32

C2012A' H Overall size 2040x1200mm (Type C2012A') No. 32

C2012C I Overall size 2040x1200mm (Type C2012C) No. 32

C2112' J Overall size 2100x1200mm (Type C2112') No. 64

C2112A K Overall size 2150x1200mm (Type C2112A) No. 32


C2112A' L Overall size 2150x1200mm (Type C2112A') No. 32

C2112E' M Overall size 2130x1200mm (Type C2112E') No. 32

C2212' N Overall size 2210x1200mm (Type C2212') No. 64

C2212B' O Overall size 2230x1200mm (Type C2212B') No. 32

C2312A P Overall size 2300x1200mm (Type C2312A) No. 32

C2312A' Q Overall size 2300x1200mm (Type C2312A') No. 32

C2312B R Overall size 2380x1200mm (Type C2312B) No. 32

C2312C S Overall size 2360x1200mm (Type C2312C) No. 32

C2412 T Overall size 2400x1200mm (Type C2412) No. 32

C2412B U Overall size 2420x1200mm (Type C2412B) No. 64

C2412B' V Overall size 2420x1200mm (Type C2412B') No. 32

C2412C W Overall size 2485x1200mm (Type C2412C) No. 32

C2512A X Overall size 2580x1200mm (Type C2512A) No. 64

C2512B Y Overall size 2500x1200mm (Type C2512B) No. 64

C2712A' Z Overall size 2700x1200mm (Type C2712A') No. 32

C2712B Z Overall size 2765x1200mm (Type C2712B) No. 64

Page : Bill 4.2/3 1,088

Ref Description Unit Qty

4.2 METAL WORKS (CONT'D)

ALUMINIUM WINDOW (CONT'D)

Glass windows and aluminium alloy frames


complete with approved ironmongeries, accessories,
flashings with and including all fixings, packing pieces,
fastenings, sealants to structure and grouting as
specified (Cont'd)

C3012A A Overall size 3040x1200mm (Type C3012A) No. 32

C3012B' B Overall size 3095x1200mm (Type C3012B') No. 32


Page : Bill 4.2/4 64

Ref Description

4.2 METAL WORKS

Sub-Collection

Page : Bill 4.2/1

Page : Bill 4.2/2

Page : Bill 4.2/3

Page : Bill 4.2/4


Page : Bill 4.2/5

Ref Description Unit Qty

4.3 WALL CEILING FINISHINGS

IN-SITU FINISHES

Cement and sand plaster; as specified

Externally

plwext A To wall; to concrete surface m2 9,778

plw B To wall; to AAC surface m2 20,253

C 0.8mm dia galvanized to external wall m2 29,632


finishing layer

D To wall; 18mm to roof deck, dog house and LMR m2 335

Skimcoat

Externally

E To wall and column ; roof deck, dog house and LMR m2 1,284

F To beam; 20mm thick to crown m2 1,348

WATERPROOFING SYSTEM

1.5mm thick JS waterproof layer; applied strictly in


accordance with manufacturer's instruction; as
specified in the Drawing

wp G To wall; balcony m2 458


Page : Bill 4.3/1

Ref Description

4.3 WALL CEILING FINISHING

Page : Bill 4.3/1


Page : Bill 4.3/2

Ref Description Unit Qty

4.4 PAINTING, POLISHING AND OTHER


SIMILAR WORK

WEATHERSHIELD PAINT

M104 A To wall: unit outside; Type SK Sipokaken (ex. SKK) m2 7,957

M105 B To wall: unit outside; Type CK Ceraskaken (ex. SKK) m2 5,306

M106 C To wall: unit outside; SL Super Lenaflex (ex. SKK)- non texture m2 16,369

D To Pipe: unit outside m 1,261

F To beam: crown; Type CK Ceraskaken (ex. SKK) m2 526

To wall; roof deck, dog house and LMR; SL Super Lenaflex (ex.
H m2 335
SKK)- non texture

I To parapet wall; Type SK Sipokaken (ex. SKK) m2 136

J To parapet wall; Type CK Ceraskaken (ex. SKK) m2 210

K To parapet wall: ; SL Super Lenaflex (ex. SKK)- non texture m2 306


Page : Bill 4.4/1

Ref Description

4.4 PAINTING, POLISHING AND OTHER SIMILAR WORK

Sub-Collection

Page : Bill 4.4/1


Page : Bill 4.4/2

Ref Description Unit Qty

4.5 OTHERS

Allow herein for any other work not mentioned above but
specified and/or shown in the Specification and/or
Drawings which are considered necessary for the full
and satisfactory completion for the works.
The Contractor is to list out the items below and indicate
the cost breakdown against each item

C
Page : Bill 4.5/1

Ref Description

4.5 OTHERS

Sub-Collection

Page : Bill 4.5/1


Page : Bill 4.5/2

Ref Description

BILL 4.0 - APARTMENT FAÇADE

Collection

Page : Bill 4.1/2 BRICKWORK AND BLOCKWORK

Page : Bill 4.2/5 METAL WORKS

Page : Bill 4.3/3 WALL CEILING FINISHINGS

Page : Bill 4.4/2 PAINTING, POLISHING AND OTHER

Page : Bill 4.5/2 OTHERS


Page : Bill 4.6/1
Supply Rate Install Rate All-in Unit Rate Total Amount
Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
To Sub-Collection
Total Amount
(IDR)
To Collection

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

4,284,909 702,167 4,987,076 797,932,093

5,772,066 918,520 6,690,587 1,284,592,632

6,187,605 1,038,499 7,226,103 924,941,195

6,508,829 1,321,725 7,830,554 2,505,777,305


To Sub-Collection 5,513,243,225

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

1,513,186 236,022 1,749,209 55,974,677

1,580,352 283,227 1,863,579 119,269,077


1,614,340 283,227 1,897,567 364,332,779

1,580,352 283,227 1,863,579 59,634,539

1,755,178 368,195 2,123,373 67,947,935

1,734,302 370,555 2,104,857 336,777,074

1,690,359 332,792 2,023,150 129,481,624

1,772,463 377,636 2,150,099 68,803,167

1,772,463 377,636 2,150,099 550,425,339

1,945,314 472,045 2,417,359 154,710,989

1,913,215 472,045 2,385,260 76,328,325

1,988,527 495,647 2,484,174 79,493,576

2,104,363 594,776 2,699,139 86,372,455

2,129,467 613,658 2,743,125 87,780,006

2,151,433 630,180 2,781,613 178,023,226

2,167,123 641,981 2,809,104 89,891,332

2,167,123 641,981 2,809,104 89,891,332

2,167,123 641,981 2,809,104 89,891,332

2,167,123 641,981 2,809,104 89,891,332

2,179,675 651,422 2,831,097 90,595,108

2,211,056 675,024 2,886,080 92,354,547

2,211,056 675,024 2,886,080 92,354,547

2,292,644 736,390 3,029,034 193,858,176


2,273,816 722,229 2,996,045 95,873,425

2,317,748 755,272 3,073,020 98,336,639

2,361,681 788,315 3,149,995 100,799,854

To Sub-Collection 3,539,092,414

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)

2,361,681 788,315 3,149,995 100,799,854

2,361,681 788,315 3,149,995 100,799,854

2,576,227 840,240 3,416,466 218,653,839

2,380,509 802,476 3,182,985 101,855,517

2,620,159 873,283 3,493,442 111,790,134

2,588,779 849,681 3,438,459 110,030,695

2,673,505 913,407 3,586,912 114,781,180

2,739,404 962,971 3,702,375 118,476,002

2,804,886 962,971 3,767,857 120,571,428

2,777,060 991,294 3,768,354 241,174,657

2,808,440 1,014,896 3,823,336 122,346,767


2,808,440 1,014,896 3,823,336 122,346,767

2,795,888 1,005,455 3,801,343 121,642,992

2,846,096 1,043,219 3,889,315 248,916,188

2,858,649 1,052,660 3,911,308 125,161,870

2,902,581 1,085,703 3,988,284 127,625,084

2,902,581 1,085,703 3,988,284 127,625,084

2,952,789 1,123,467 4,076,256 130,440,186

2,940,237 1,114,026 4,054,263 129,736,411

2,965,341 1,132,907 4,098,249 131,143,962

2,977,893 1,142,348 4,120,242 263,695,475

2,977,893 1,142,348 4,120,242 131,847,738

3,018,688 1,173,031 4,191,719 134,135,008

3,078,310 1,217,876 4,296,186 274,955,884

3,028,102 1,180,112 4,208,214 269,325,680

3,153,623 1,274,521 4,428,144 141,700,595

3,194,417 1,305,204 4,499,621 287,975,732

To Sub-Collection 4,229,554,582

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
3,517,553 1,435,016 4,952,569 158,482,205

3,552,071 1,460,979 5,013,050 160,417,588


To Sub-Collection 318,899,792
Total Amount
(IDR)

5,513,243,225

3,539,092,414

4,229,554,582

318,899,792
To Collection 13,600,790,013

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
To Sub-Collection
Total Amount
(IDR)
To Collection

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
To Sub-Collection

All-in Unit Rate Total Amount


(IDR) (IDR)
To Collection

Supply Rate Install Rate All-in Unit Rate Total Amount


Qty (+/-)
(IDR) (IDR) (IDR) (IDR)
To Collection

All-in Unit Rate Total Amount


(IDR) (IDR)
To Collection
Total Amount
(IDR)

13,600,790,013