You are on page 1of 2

ESTEEM OUTCOMES AND SUMMARY REPORT

Beam

As Req Steel bar Shear link area Spacing Deflection


ESTEEM 120 mm² 2T12 628 T10-250 1.50
MANUAL 158 mm² 2T12 344 T10-300 1.43

The design used for beam analysis was positioned at gridline 2A/B-B1 on the ground floor. The beam
construction was recognised as a simply supported flanged beam with a length of 3.2 metres. This beam
was designed to support loads from slabs FS3-3 and FS2-1 with dimensions of 3.2 metre x 1.2 metre. The
beam has a diameter of 200 millimetres and a height of 500 millimetres. The ESTEEM programme
assessed the value of bar required for beam gb5 (As Req) to be 120 mm2 and the use of 2T12 to be 226
mm2. Manual calculation, on the other hand, reveals that the value of bar required for this beam is
158mm2 with the use of 2H12 of steel bar. The difference between software ESTEEM calculation and
manual calculation reveals a difference of 24.05 percent from software calculation, which was chosen as a
benchmark to compare the two calculations.

Slab

As Req Spacing Deflection


ESTEEM 210 mm² T10-250 1.50
MANUAL 243 mm² T10-250 1.29

The slab structure used in this discussion is known as slab FS5, and it is positioned on the ground floor.
The slab is reported to be 5.1 metres wide, 4.4 metres long, and 0.125 metres thick. This slab was
identified as a two-way constrained slab because the force was divided into four beams surrounding the
slab. According to the ESTEEM software results, the area required of steel bar (As Req) is 210mm² with
H10-250 for bottom and top steel mesh. Manual calculation of 243.25mm² steel mesh area using the same
H10-250 steel mesh use. The difference between two calculations of needed steel bar (As Req) is just
15.71 percent, suggesting that steel mesh of the same size and spacing should be used.

Column
As Req Steel bar Shear link area Spacing Deflection
ESTEEM 120 mm² 4T12 628 T10-125 1.50
MANUAL 158 mm² 4T12 344 T10-200 1.43

The column used in this discussion is known as column c 13: 3b : Ground floor- first floor. The column
with length 3metre and wide 3metre also. This column identified as slender about at the both axis y and
axis z. According to the ESTEEM software result,

Foundation

As Req Spacing Deflection


ESTEEM 210 mm² T10-250 1.50
MANUAL 243 mm² T10-250 1.29

The foundation in this discussion use column size as 300x300mm. Based on Esteem 10 report,