tunnel even in a power outage or don't have access. The project was designed to
quickly shift either the power from a solar power system or the electricity from an
electrical distributor.
control for disinfection. The solar power system comprises a solar panel, solar
charge controller, and battery. At the same time, the automation control makes
up of a relay, switch, motion sensor, and water pump. These components are
organized into a built case to give it a clean look and easy access if needed for
avoid electrocution. The prototype motion sensor range was adjusted to detect
SYSTEM FEATURES
electrical supply system has the benefit of reducing the electricity costs due to
the solar energy system. The project also uses the electric source from electrical
distribution companies like Meralco for the automatic disinfection tunnel, allowing
it to continue operating even after the solar battery is empty or low in charge. The
project can also be used even if there is a power outage, unlike conventional
automatic disinfection tunnels that can only use one power source.
The motion sensor sends a signal to the relay when someone enters the
tunnel, starts the water pump, and sprays the disinfection solution. The existing
automatic disinfection tunnel has this function; however, the technology and
components are different in this project. The tunnel was built with low-cost
48
materials such as PVC pipe and a plastic cover, but it was reinforced to
automatic disinfection tunnel project employing a hybrid on-grid system, and the
electric provider Meralco. Before turning on the main switch, the researcher tests
the power supply's output voltage to match the needed supply for the load. After
that, the researcher fills the disinfectant solution container with water for testing
purposes. The researcher also checks if the nozzle is appropriately labeled and
secured. Next, the researcher tested the motion sensor to detect motion and
49
adjusted its range so it would only detect motion upon entering the disinfection
tunnel.
system. The researcher checked the solar power system components were
connected correctly. The researcher checks the solar charge controller to check
if it reads the battery and the solar panel. Then test if the battery is charging
correctly and if the solar panels harvest power. Finally, the researcher tested if
The following data below shows the project’s result upon successfully testing:
1. After connecting the solar power components, the solar charge controller
2. The researcher found that the output pressure of the water pump is
4. The researcher found that the output released by the nozzle head is
particularly larger than the expected outcome but works to its purpose and
function.
5. The automatic transfer switch works perfectly smoothly from shifting from
PROJECT EVALUATION
Technology Management (CTM), and ten (10) randomly selected student from
grouping is to understand how each group regards the project’s practicality and
acceptability.
from one to five levels for each criterion, with one being the lowest and five being
the highest. The project evaluation used weighted mean X to determine the level
of acceptability of the project after tabulating the data gathered. The numerical
equivalent as follows:
Table 4
The data presented in Table 4 shows the mean rating given by the
acceptability of the project. The result of the given evaluation shows that almost
the entire criterion indicator got a mean rating of 4.8, equivalent to an excellent
rating. The highest rating was the project's appearance, with a total mark of 5
ratings.
Table 5
CRITERIA
electrical students find the automatic disinfection tunnel that uses a hybrid
Table 6
Indicator
The data presented in Table 6 shows the mean rating provided by the
indicators of the project's acceptability. The result of metrics from the College of
rating for almost all criterion indicators. The lowest mean rating landed on the
toughness of the project, the properly labeled the mist spray, the carrying weight
is manageable, and the electronic and electrical device is easy to maintain got
Table 7
CRITERIA
CONSTRUCTIO EASE SAFETY IN PORTABILIT MAINTENANC
N OF OPERATIN Y OF THE E
OF THE USING G THE PROJECT REQUIREMEN
DESIGN THE PROJECT TS
DEVICE
1. 1. 1. 1.4 2. 2. 2 3.1 3. 3. 4. 4. 4. 4 5.1 5.2 5.3
1 2 3 .1 2 . 2 3 1 2 3 .
3 4
4.8+4.8+4.8+4.8 4..8+4.8+ 4.8+4.6+4.8 4.6+4.8+4.6+4 4.8+4.8+4.6
4.8 .8
19.2 14.4 14.2 18.8 14.2
OVERALL 19.2+14.4+14.2+18.8+14.2
MEAN 17
(X)
X= 4.7 DESCRIPTIVE RATING - EXCELLENT
55
Table 7 shows the cumulative mean of the ratings. The overall mean of
equivalent. This suggests that the automatic disinfection tunnel using a hybrid
Table 8
by Criterion Indicator
The data presented in Table 8 shows the mean rating of the University of
Makati students from different colleges, based on the various indicator of the
57
project acceptability. The result of the metric appears Excellent for students from
design, the ease of using the project, and the safety of operating the projects.
The highest mean rating went to the project's appearance with a 4.9 rating which
had a descriptive rating of Excellent. Then the lowest mean rating given by the
students falls to the toughness of the project with a mean rating of 3.8 with a
Table 9
Evaluation
CRITERIA
Construction Ease Of Safety In Portability Of Maintenance
Of The Design Using The Operating The Project Requirements
Device The Project
1.1 1. 1. 1.4 2.. 2. 2. 3.1 3. 3.3 4 4.2 4. 4.4 5.1 5.2 5.
2 3 1 2 3 2 . 3 3
1
4.6+4.8+4.9+4.7 4..7+4.7+4. 4.6+4.6+4.7 3.8+4.7+4.5+4. 4.7+4.7+4.5
7 8
19 14.1 13.9 17.8 13.9
OVERALL MEAN 19+14.1+13.9+17.8+13.9
(X) 17
X= 4.6 DESCRIPTIVE RATING - EXCELLENT
Table 9 shows the cumulative mean rating of the students from different
colleges in the UMAK evaluation. The overall mean exhibits a 4.6 rating with a
58
descriptive equivalent of an excellent rating. This suggests that the students from
different colleges of UMAK think that the automatic disinfection tunnel using a
OVERALL EVALUATION
Table 10
RATING
that utilizes the use of a hybrid electrical supply system from the evaluator's
The design of the project’s prototype got the highest aggregated mean
with a 4.80 rating with a descriptive equivalent excellent rating. Among the panel
of evaluators, the electrical students give the highest rating of 4.85, which means
aggregated mean of 4.80 ratings shows that the quality of the design
because it got an aggregate mean of 4.76 ratings with an excellent rating. This
device amidst this Corona Virus pandemic. Among the evaluators, the students
from the different colleges of the University of Makati give the lowest mean rating
of 4.63, which still have an excellent descriptive rating. This suggests that even
with an aggregate mean of 4.72 ratings, the project's prototype may need more
Among the different criteria for the project's acceptability, the portability
got the lowest aggregate mean rating of 4.65. This suggests that the project
structure may need a lot of attention while transporting from one place to another
and may need improvement in the material used for the tunnel frame.
Maintenance Requirements
condition and smooth operation to avoid an accident. The aggregate mean of the
excellent rating. This indicates that the project’s components are easy to
Table 11
63
Grand Mean of all the rating obtained by the automatic disinfection tunnel
CRITERIA
(X) 5
the various criteria. As shown in the table, the automatic disinfection tunnel had
Excellent rating. This final assessment of the statistical analysis shows that the
supply