You are on page 1of 4

Rockfall

Protection System
TSC-250-ZD
Classification

Model TSC-250-ZD
Style Hinged System
Energy Class 1
Maximum Energy Level 250 261
Certified/Tested kJ (ft-tons) (92) / (96)
Service Energy Level 85 (31)
kJ (ft-tons)
Approved Heights m (ft) 2.5 - 3.0 (8.2 - 9.8)
Verification Full Scale Tested
Certification ETAG 27 Certified

Test Report Summary

Area of Application: Test Height m (ft) 2.5 (8.2)


TRUMER rockfall catchment fences were developed to protect
Maximum Elongation m (ft) 3.86 (12.66)
infrastructure, utilities, buildings and lives from falling debris.
Typical catchment fences are installed in run-out or deposition Residual Height Class A (≥50%)
zones, close to the elements at risk that they protect. The Component Failure None
TSC-250-ZD is used for projects of high risk (Consequence Class Primary Net Opening None
CC3 in EN 1990:2003 [1]) as per ONR 24810 [2].
Secondary Mesh None
Material:
TRUMER uses steel components and steel wire ropes made from European Technical Assessment
high quality materials, following a stringent quality assurance ETA
program. The structure was tested as per ETAG 27 [3] and
manufactured in accordance with the European Technical ETA Number ETA-12/0204
Assessment ETA-12/0204. TRUMER Schutzbauten GmbH is OIB Austrian Institute
ISO 9001:2015 certified. Issuing Body of Construction
Engineering
Installation:
The TSC-250-ZD has been designed with as few components as Date of Issue October 02, 2017
possible to simplify installation and reduce maintenance. In
addition, the systems can be installed by hand, with heavy Certificate of Constancy of
machinery or with the use of a helicopter. Foundation design and Performance
construction is dependant on site conditions and are the
responsibility of the project engineer. Certificate Number 1379-CPR-022/14

Issuing Body TVFA-ZERT


Advantages:
TU Graz
This system has been tested with no failures of primary
components even though certification allows such failures. As Date of Issue July 26, 2017
such, the TSC-250-ZD rockfall catchment fence carries the
highest safety ratings.

Trumer Schutzbauten GmbH • Weissenbach 106 • 5431 Kuchl • Austria


Tel.: +43 6244 20325 • Fax: +43 6244 20325-11 • www.trumer.cc

03/2022 TSC-250-ZD 1/4


Primary Net Base Plate/Foundation

Model Omega-Net 6.0/135 Hinge Pin


Type Steel Wire Cable
Post Anchor Nut
Rope Diameter mm (in.) 6.0 (0.236)
Base Plate
Rope Construction 1 x 7 Spiral Lower
Anchor
Single Wire Diameter mm (in.) 2.0 (0.078) Bearing
Rope
Corrosion Protection Zn or ZnAl (Class A) Anchor
Mesh Size mm (in.) ~ 135 x 135 (5.3 x 5.3) Nut

Unit Weight kg/m (lb/ft )


2 2
~ 3.6 (0.74)
F k,par 45°
Mesh Tensile Strength 246 (16856)
calculated kN/m (lbf/ft) Micropile Anchor
Tube
Connection to Main Ropes Threaded
Connection to Adjacent Panel 5/16” Shackle
Lateral Anchorage

Ropes
Anchor
Quantity per fence segment 2 Loop
Bearing

Rope Diameter mm (in.) 16 (0.630)


Corrosion Protection Zn or ZnAl (Class A or B) Brake Element
Brake Elements per rope 2
Brake Element Model AVT phx 60/30-1.5 Anchor

Quantity per fence segment N/A


t

Rope Diameter mm (in.) N/A F k,la


Middle

Upper Bearing Rope


Lower Bearing Rope
Corrosion Protection N/A Side Stabilization Rope
Brake Elements per rope N/A
Brake Element Model N/A
Quantity per post 2 Retaining Rope Anchorage
Retaining

Rope Diameter mm (in.) 12 (0.472)


Corrosion Protection Zn or ZnAl (Class A or B) Anchor

Brake Elements per rope N/A


Fk,ret

Brake Element Model N/A Anchor


Loop

Retaining Rope
Retaining Rope
Support Structure

Post Type HEA 100


Integrated Ladder Rungs every 0.5 m
Rope Guides Integrated
Post Weight 65 (143)
2.5 meter post height kg (lbs)
Anchor Forces kN (kips)
Base Plate Connection Tongue and Pin
Base Plate Footprint mm (in.) 650 x 200 (25.6 x 7.8) Base Plate (Fk,par) 98 (22.0)
Base Plate Weight kg (lbs) 29 (64) Max. Lateral Anchor (Fk,lat) 186 (41.8)
Anchors per base plate 2 Retaining Rope Anchor (Fk,ret) 88 (19.8)

03/2022 TSC-250-ZD 2/4


Typical Recommended Anchors Based on Steel Grade*
(per 50 m, 10 m post spacing)

Quantity 500/550 (MPa) 670/800 (MPa) 470 min (MPa)


(e.g. GEWI) (e.g. GEWI Plus) (e.g. IBO)

Base Plate Anchor 12 25 22 site dependent


Lateral Anchor 2 32 25 R32-400
Retaining Rope Anchor 7 25 22 R32-210
* Actual anchorage to be determined by a qualified engineer in accordance with local regulations. Herein, the factors of
safety were applied according to the ONR 24810 guidelines. If multiple ropes are led to one anchor, it is recommended
that characteristic force values be added in a scalar manner according to ONR 24810.

Typical Cross Section General Layout and Anchorage:


The suggested layout for the
rockfall catchment fence follows
Rope Guide the constructive rules of the ONR
Retaining Rope
24810. In general, post spacing is
kept between 8 - 12 m (26 - 39 ft).
Anchor
Eye Retaining Rope Posts should be positioned to
Post Anchor create the greatest capture shadow
with regards to vertical as well as
lateral spread of falling debris, with
)

the fence roughly perpendicular to


9.8 ft

the fall line. Avoid the placement of


(8.2 -

posts in areas that increase the


3.0 m

chance of a direct post impact.


Base Plate
2.5 -

Anchor layout should follow the


20
ft) geometry provided in the
-
16 installation manual with the anchor
6 m(
5-
oriented as close as possible to the
direction of the anticipated rope
Base Plate forces. It is acknowledged that due
Anchor to site characteristics deviations
from the ideal are unavoidable. In
this case, the project engineer
should use their best judgement to
find a suitable location and
orientation.

Typical Layout

4-6m
(13 - 20 ft) 8 - 12 m (26 - 39 ft)
Retaining Rope
Anchor
5 - 6 m (16 - 20 ft)

Lateral
Anchor

Upper Bearing Rope Lower Bearing Rope


5 - 6 m (16 - 20 ft)
Retaining Rope Side Stabilization Rope

03/2022 TSC-250-ZD 3/4


MEL Pre-test Photo, Side MEL Post-test Photo, Side

References:
1. CEN. EN 1990:2003, Eurocode – Basis of structural
design, 2005.

2. Austrian Standards Institute. ONR 24810,


Technical protection against rockfall - Terms and
definitions, effects of actions, design, monitoring and
maintenance, 2013.

3. EOTA. Guideline for European technical approval


of falling rock protection kits (ETAG 27), February
2008.

MEL Pre-test Photo, Front

MEL Post-test Photo, Front

Tested Energy Level 261


kJ (ft-tons) (96)

03/2022 TSC-250-ZD 4/4