Manifold Specifications
How to Order Manifold
···
Nil
10 10 stations Nil None 1 100 VAC, 50/60 Hz
Note) When equipped with SB With 2 200 VAC, 50/60 Hz VF
control unit, 1 or 2 Note) The silencer box 3 24 VDC
stations are used for mounting position 4 12 VDC
mounting. corresponds to
9 Other
VFR
piping connection
2 (B), 4 (A) port connection at ports 3 (R2)
and 5 (R1). VP4
02R Rc 1/4 (Right side)
03R Rc 3/8 (Right side) Thread type
02L Rc 1/4 (Left side) Nil Rc
VZS
1(P), 3(R2), 5(R1) port connection
03L Rc 3/8 (Left side) F G
02Y Rc 1/4 (Bottom side)
02D Rc 1/4 (Bottom side)
T NPTF VFS
02U Rc 1/4 (Top side)
03Y Rc 3/8 (Bottom side) Note) It is not applicable to
02B Rc 1/4 (Both sides)
C6R One-touch fitting ø6 (Right side)
03D Rc 3/8 (Bottom side)
One-touch fittings. VS4
C8R One-touch fitting ø8 (Right side)
03U Rc 3/8 (Top side)
C10R One-touch fitting ø10 (Right side)
One-touch fitting ø6 (Left side)
03B Rc 3/8 (Both sides) VQ7
C6L
C12D One-touch fitting ø12 (Bottom side)
C8L One-touch fitting ø8 (Left side)
C10L One-touch fitting ø10 (Left side)
C12U One-touch fitting ø12 (Top side) EVS
C12B One-touch fitting ø12 (Both sides)
∗ Mixed
∗ Mixed
Note) When ports are mixed, indicate VFN
piping specifications by means of Note) When ports are mixed, indicate
the manifold specification sheet. piping specifications by means of
the manifold specification sheet.
Thread type Control unit type (See pages 3-10-18 and 19 for details.)
Nil Rc Symbol Nil A AP M MP F G C E
Control equipment
F G
T NPTF Air filter with auto-drain
Note) It is not Air filter with manual drain
applicable to Regulator
One-touch Air release valve
fittings. Pressure switch
Blanking plate
(Air release valve)
Blanking plate
(Filter, Regulator)
Blanking plate
(Pressure switch)
Number of manifold blocks 2 2 2 2 2 2 2 1
required for mounting (stations)
Manifold Specifications
Porting specifications
Manifold Applicable Weight
2(B), 4(A) port 1(P), 3(R2) Stations
block size solenoid valve (kg)
Port location Port size 5(R1) port size
1/4
3/8
Series Right, Left C6 (ø6) 1/4 Note)
ISO size 1 VQ7-6 C8 (ø8) 3/8 Max. 10 0.43n + 0.49
ISO size 1 C10 (ø10) C12 (ø12) stations (n: Stations)
1/4
Bottom
3/8
Note) When equipped with control unit, 1 or 2 stations are used for mounting.
3-10-11
Series VQ7-6
DIN Terminal Type
VV71쏔-쏔-쏔쏔쏔
100
100 80
80 2n-1/4, 3/8 37 23
9 14 9
15
U side U side
Manual
53.5
.5
Indicator light
.5
override
53.5
R4
R4
B
B
9 9
B
23 20
SMC
P = 43
P = 43
A
PA
A
B
B
B
SMC
A
PA
A
B
B
L1
L2
L2
L1
B
SMC
A
PA
A
B
B
SMC
A
PA
A
B
A
4n-1/4, 3/8
PA
(A, B port)
L side R side (2n-1/8) R side L side
D side 38 D side
68.5 3 68.5
120.5 (Single) 16 120.5 (Single)
145 (Double) 44 145 (Double)
155 (3 position)
55 155 (3 position)
77.5
Bottom ported drawing
165.5
153.5
121
14 12
51
PA PB
3 R
65
54
4-1/8 P
39
21
(Pilot pressure R1
MC
R2
EXH port)
17 17 6-3/8
(P, R port)
26.5 26.5
L Dimension n: Stations
1 2 3 4 5 6 7 8 9 10 Formula
L1 107 150 193 236 279 322 365 408 451 494 L1 = 43n + 64
L2 119 162 205 248 291 334 377 420 463 506 L2 = 43n + 76
3-10-12
ISO Standard Solenoid Valve: Size 1
Metal Seal/Rubber Seal Series VQ7-6
Prewired Connector Type
VV71쏔-쏔-쏔쏔쏔
100
80
9 14
U side
15
Indicator light
.5
53.5
R4
Manual override
VK
B
SMC
23 20
B
A
9
VZ
P = 43
PA
A
B
VF
SMC
B
A
VFR
PA
A
B
VP4
L1
L2
SMC
B
A
PA
A
VZS
B
SMC
A
VFS
PA
A
B
VS4
VQ7
PA
A
L side R side (2n-1/8)
EVS
38
D side
68.5 3
VFN
4n-1/4, 3/8 16
120.5 (Single) (A, B port) 44
145 (Double)
55
155 (3 position) 77.5
121
14 12
PA 1 PB
5 3 R
65
54
P
39
4-1/8 SMC
21
17 17
26.5 26.5 6-3/8
(P, R port)
L Dimension n: Stations
1 2 3 4 5 6 7 8 9 10 Formula
L1 107 150 193 236 279 322 365 408 451 494 L1 = 43n + 64
L2 119 162 205 248 291 334 377 420 463 506 L2 = 43n + 76
3-10-13
Series VQ7-6
Manifold Option Parts
Blanking plate assembly Block disk (For SUP/EXH passages)
AXT502-9A AXT502-14
It is used by attaching on the manifold block for being When two or more different high pressures are supplied to one
prepared for removing a valve for maintenance manifold, block disks are installed between stations having
reasons or planning to mount a spare valve, etc. different pressures.
Also, in cases such as when valve exhaust effects other stations
in a circuit, block disks are used for exhaust at stations where the
exhaust is to be separated.
4 2
5 5 5
1 1 1
3 3 3
1'
5 3
1
4
2
5 3
3'
5 3
3-10-14
ISO Standard Solenoid Valve: Size 1
Metal Seal/Rubber Seal Series VQ7-6
5 3
VP4
5 3 3'
VZS
VFS
R1, R2 individual EXH spacer Individual SUP spacer with residual pressure release valve
VS4
VV71-R2-03쏔 VV71-PR- 02 03 쏔
3'
5'
1'
3'
5 3
5 3
Main EXH back pressure check plate Adapter plate for locked-up cylinder
AXT503-37A AXT502-26A
In cases where back pressure effects actuator operation due to When using a locked-up cylinder with 2 valves for control, this
simultaneous operation of manifold valves, etc., this effect can be spacer can be used by mounting on a manifold block. It
eliminated by installing a plate between the manifold block and consists of a circuit equipped with a function to prevent
the valve from which back pressure is to be prevented. lurching during release.
1
1
4
2
5 3 5 3
3-10-15
Series VQ7-6
Manifold Option Parts
Silencer box Pilot EXH silencer
VV71-쏔쏔쏔-쏔쏔-SB AN110-01
This can be provided as a unit on the end plate to This is used by mounting on the pilot exhaust port in order to
reduce manifold exhaust noise and piping labor. reduce manifold and single type pilot exhaust noise, and to
prevent the entry of dust.
1'
5 3
3-10-16
ISO Standard Solenoid Valve: Size 1
Metal Seal/Rubber Seal Series VQ7-6
Double check spacer Double check spacer with residual pressure release valve
VV71-FPG VV71-FPGR
By combining a 3 position exhaust center valve with a double check This is a double check spacer equipped with a residual
spacer, an intermediate stopping position of a cylinder can be held pressure release function, to release residual pressure
for an extended period. It can also be used for drop prevention at inside a cylinder during maintenance or adjustment, etc.
the cylinder stroke end when releasing residual supply pressure, by 4 2
1
combining it with a 2 position single or double valve.
VK
VZ
VF
VFR
5 3
VP4
Caution VZS
4
• Since extended cylinder stops are not possible if there are leaks
1
2 from piping between the valve and cylinder or from fittings, etc., VFS
check for leakage using a neutral liquid detergent.
• Since One-touch fittings allow slight air leakage, screw piping
(with M5 thread) is recommended when stopping the cylinder in
VS4
the middle for a long time.
• This spacer cannot be combined with a 3 position closed center VQ7
valve.
• Set the load weight so that the cylinder side pressure is less than EVS
5 3 two times the supply side pressure.
Specifications • When using the residual pressure release function, confirm the
Double check spacer part no. VV71-FPG
VFN
action of actuators, etc., and operate after providing for safety
Applicable solenoid or air operated valve Series VQ7-6 measures.
One solenoid energized R1
P 130
(One pilot pressurized) R2
Leakage R1
P 130
(cm3/min (ANR)) Both solenoids unenergized R2
(Both pilots unpressurized) B R1
0
A R2
Interface regulator
P
ARB250-00- A
B
Spacer Interface regulators can be placed on top of the manifold block to reduce the pressure of each of the valves.
1 42 1 42 1 42
5 3 5 3 5 3
Regulating port A Regulating port B Regulating port P
3-10-17
Series VQ7-6
Control Unit
Control equipment (filters, regulators, pressure switches, air release valves) has been made into standardized units which can be mounted on manifolds
without any modifications.
Option
AXT502-9A (For manifold)
AXT502-18A (For release valve adapter plate)
Blanking plate
MP2 (For control equipment/filter regulator)
MP3 (For pressure switch)
Release valve adapter plate AXT502-17A
VAW-A (Adapter plate, Filter with auto-drain cock, Regulator)
Control equipment
VAW-M (Adapter plate, Filter with manual drain cock, Regulator)
Pressure switch IS3100-X230
3-10-18
ISO Standard Solenoid Valve: Size 1
Metal Seal/Rubber Seal Series VQ7-6
15
.5
VZ
53.5
Manual override L side R side
R4
B
B
VF
SMC
23 20
P = 43
9
PA
A
VFR
B
B
SMC
VP4
PA
A
B
B
L1
L2
SMC
VZS
PA
A
Indicator light
B
VFS
SMC
PA
L3
VS4
B
Release valve
VQ7
PA
38
EVS
SMC
VFN
D side
9
124 89
P
138
14 12
1
3/8 PA PB
84
Supply port
65
5 3 R
54
4-1/8
39
P
21
9 4-3/8
17 17 (R1, R2 port)
26.5 26.5
L Dimension n: Stations
1 2 3 4 5 6 7 8 9 10 Formula
L1 107 150 193 236 279 322 365 408 451 494 L1 = 43n + 64
L2 119 162 205 248 291 334 377 420 463 506 L2 = 43n + 76
255 298 341 384 427 470 513 556 599 642
L3 L3 = 43n + 212 (215.5)
(258.5) (301.5) (344.5) (387.5) (430.5) (473.5) (516.5) (559.5) (602.5) (645.5)
L3 dimensions inside ( ) are for MP.
3-10-19
Series VQ7-6
Manifold Option Parts
Interface regulator Residual pressure release valve spacer
P
ARB250-00- A AZ503-82 AB
B
SMC
SMC
205.5 (177.5)
195.5 (167.5)
193.5 (165.5)
183.5 (155.5)
Manual override
E R
Residual pressure
105 (77)
B 14 12
release valve spacer
(AZ503-82 AB )
1
95 (67)
PA
65 (37)
PB
B 14 12
PA PA 1
PB
5 3 R
65 (37)
A
PA
P 5 3 R
SMC A
R1 R2 P
SMC
R1 R2
Dimensions inside ( ) are for sub-plate. Dimensions inside ( ) are for sub-plate.
SMC
191.5 (163.5)
179.5 (151.5)
SMC
165.5
153.5
R1 EA
S
L
O
W
114
B 14 12
91 (63)
12 PA 1
B 14 PB
PA 1 PB
PA
65 (37)
PA
5 3 R
62
5 3 R
A A
P P
SMC SMC
R1 R2 R1 R2
3-10-20
ISO Standard Solenoid Valve: Size 1
Metal Seal/Rubber Seal Series VQ7-6
SMC
VK
SMC
2n-1/4, 3/8
VZ
205.5 (177.5)
193.5 (165.5)
195.5
183.5
VF
105 (77)
B 14 12
VFR
95
PA 1 PB
B 14 12
1
PA PA PB
65 (37)
65
5 3 R PA
5 3 R
A
SMC
P A
P
SMC
VP4
R1 R2 R1 R2
SMC
195.5 (167.5)
SMC
183.5 (155.5)
173.5
161.5
95 (67)
B 14 12 B 14 12
PA 1 PB 1 PB
PA
65 (37)
PA PA
73
5 3 R
5 3 R
65
A
A P
P
SMC
R1 R2
SMC
R1 R2