Professional Documents
Culture Documents
Table of contents
References
Preliminary Requirements
Procedure
Requirements After Job Completion
List of tables
1 References
2 Access points
3 Zones
4 Required Conditions
5 Support Equipment
6 Supplies
7 Spares
List of figures
1 Central maintenance system (CMS) - Performance database - Operational software
loading procedures
2 File selection page
References
Table 1 References
Data Module Title
39-A-00-20-00-00A-120A-A Helicopter safety - Pre-operation (make helicopter safe for
maintenance)
39-A-12-41-00-00A-510A-A External electrical power - Disconnect procedure
39-A-12-41-00-00A-730A-A External electrical power - Connect procedure
39-A-45-45-00-00B-75CC-A Central maintenance system (CMS) - Performance
database - Operational software loading procedures
Table 3 Zones
Zone ID Data Module
No Zones
Preliminary Requirements
Required Conditions
Table 4 Required Conditions
Conditions Data Module/Technical Publication
The helicopter must be safe for maintenance 39-A-00-20-00-00A-120A-A
The access door 213AL must be open 39-A-06-41-00-00A-010A-A
Support Equipment
Table 5 Support Equipment
Identification
Nomenclature Qty
No.
PRIMUS EPIC LAN interface kit RF-01-00 1
EPIC tools for Agusta AW139/AB139 RD-03-00 1
Computer ZZ-00-00 1
Supplies
Table 6 Supplies
Nomenclature
No Supplies
Spares
Table 7 Spares
Identification
Nomenclature Qty
No.
32-00-00-01
Performance DB CD (7000 Kg) 1
-006
31-43-00-04
Performance database 1
-005
Safety Conditions
No Safety Condition
Procedure
Note
[K0756] or [K0758] To do the load of the performance database, refer to data
module 39-A-45-45-00-00B-75CC-A.
1 Make sure that the Computer (ZZ-00-00) (with Windows XP or Windows 7) is in the
correct configuration. Differently, use the PC card supplied with the PRIMUS EPIC LAN
interface kit (RF-01-00) to get the correct configuration. To do this, refer to the software-
driver installation instructions contained in the manual supplied with the kit.
2 Make sure that the EPIC tools for Agusta AW139/AB139 (RD-03-00) is installed in the
laptop computer.
3 Connect the external electrical power to the helicopter and set it to on. Refer to 39-A-12-
41-00-00A-730A-A.
Note
Two LAN ports are available for the CMC servicing operations. They are installed in
the left and right side of the nose avionic bay. Figure 1 shows the location of the LAN
ports.
5 Get access to the LAN port (2) in the nose avionics bay.
6 Remove the 50-Ohm terminator (1) from the LAN port (2).
8 Connect the BNC coaxial/RJ45 adapter to the PCMCIA PC card (part of the kit). Install
the PCMCIA card in the laptop computer.
9 Connect the connector of the coaxial cable (part of the kit) to the LAN port (2).
10 Do the performance database installation procedure. Obey the instructions that follow:
10.1 Energize the laptop computer.
10.2 If the kit 4G0000F00111 “Increase Gross Weight (IGW), until 6800 Kg” is installed, do the
steps that follow:
10.2.1 Insert the Performance database (31-43-00-04-005 ) CD-ROM in the cd-rom drive.
10.2.2 On the “DLS INSTALLATION FUNCTION” browse window, set the file
FMS_ACDB_AGST_60000218–003.
10.3 If the kit 4G0000F00311 “LGS Increased Gross Weight 7000 Kg” is installed), do the
steps that follow:
10.3.1 Insert the Performance DB CD (7000 Kg) (32-00-00-01-006 ) in the cd-rom drive.
10.3.2 On the “DLS INSTALLATION FUNCTION” browse window, set the file
FMS_ACDB_AGST_60000218–004
10.4 On the laptop computer, run the CMC RT tool. Then set the “FULL LOAD” option.
10.5 On the “DLS Installation Function” page, push the “SELECT FILE” button to install the
PERF DB. For reference only, see Figure 2 .
10.6 Remove the cd-rom from the laptop computer.
12.3 On the “Sys Config 002/016” page of the MFD, make sure that one of the PERF DB that
follows is installed:
- The PERF DB 60000218-003 (If the kit 4G0000F00111 “Increase Gross Weight
(IGW), until 6800 Kg” is installed) or
- The PERF DB 60000218-004 (if the Kit 4G0000F00311 “LGS Increased Gross
Weight 7000 Kg” is installed).
14 Remove the PCMCIA card from the laptop computer. Disconnect the BNC coaxial/RJ45
adapter from the PCMCIA card.
15 Disconnect the external electrical power from the helicopter. Refer to 39-A-12-41-00-00A-
510A-A.
1 Remove all the tools and the other items from the work area. Make sure that the work
area is clean
Figure 1 Central maintenance system (CMS) - Performance database - Operational software loading
procedures