You are on page 1of 4

PROP. TWO-STOREY BLDG QNXXXX.

1/4
FIRE PROTECTION SYSTEM THIRD FLR

Item Unit Rate (Php)


Description Qty. Unit Extension (Php)
Materials Others Total
FIRE PROTECTION SYSTEM THIRD FLR:
Supply and fix equipment and ancillaries;
including taking delivery on site, unloading or
assisting to unload, unpacking, returning packing
storing, all sundry materials for fixing, be
responsible for the safe custody of:
The following items to be supplied and fixed;
including all necessary accessories in
accordance with the specifications:

PIPES
Disposal of surplus materials offsite, and making
good to all works disturbed :
Black Iron (BI) pipes and fittings; ERW Schedule
40; jointing in accordance with the Specifications
and/or ASTM 53 Standards: Complete with pipe
supports conforming to MSS 58 & 69:

Brand: ___________________________
A Ø 100 - m
B Ø 80 - m
C Ø 65 - m
D Ø 50 - m
E Ø 40 - m
F Ø 32 - m
G Ø 25 - m

FITTINGS
Fittings are complete with mechanical grooved &
coupling system.
Brand: ________________________

90 ⁰ ELBOW

H Ø 100 - pc/s

I Ø 80 - pc/s

J Ø 65 - pc/s

K Ø 50 - pc/s
L Ø 40 - pc/s

M Ø 32 - pc/s

N Ø 25 - pc/s

FPS System A to N -
To Collection
PROP. TWO-STOREY BLDG QNXXXX. 2/4
FIRE PROTECTION SYSTEM THIRD FLR

Item Unit Rate (Php)


Description Qty. Unit Extension (Php)
Materials Others Total
FIRE PROTECTION SYSTEM THIRD FLR
CONTINUATION:
45 ⁰ ELBOW
A Ø 100 - pc/s
B Ø 80 - pc/s
C Ø 65 - pc/s
D Ø 50 - pc/s
E Ø 40 - pc/s
F Ø 32 - pc/s
G Ø 25 - pc/s

EQUAL TEE
H Ø 100 - pc/s
I Ø 80 - pc/s
J Ø 65 - pc/s
K Ø 50 - pc/s
L Ø 40 - pc/s
M Ø 32 - pc/s
N Ø 25 - pc/s

REDUCING TEE
O Ø 100 x 80 - pc/s
P Ø 100 x 50 - pc/s
Q Ø 80 x 65 - pc/s
R Ø 65 x 50 - pc/s
S Ø 65 x 40 - pc/s
T Ø 50 x 40 - pc/s
U Ø 50 x 32 - pc/s
V Ø 50 x 25 - pc/s
W Ø 32 x 25 - pc/s

ECCENTRIC REDUCER
X Ø 100 x 80 - pc/s
Y Ø 80 x 65 - pc/s
Z Ø 65 x 50 - pc/s
A1 Ø 50 x 40 - pc/s

CONCENTRIC REDUCER
B1 Ø 100 x 80 - pc/s
C1 Ø 80 x 65 - pc/s
D1 Ø 65 x 50 - pc/s
E1 Ø 50 x 40

FPS System A to E1 -
To Collection
FIRE PROTECTION SYSTEM THIRD FLR
CONTINUATION:
PROP. TWO-STOREY BLDG QNXXXX. 3/4
FIRE PROTECTION SYSTEM THIRD FLR

Item Unit Rate (Php)


Description Qty. Unit Extension (Php)
Materials Others Total

A FIRE HOSE CABINET - unit/s

Conforming to latest NFPA 14. Refer to Dwg No. FP-


4 for typical detail. (Complete with FE-ABC type)

Brand: _________________________

Fire Extinguisher
Conforming to latest NFPA 10~12.
Brand: _________________________
B FE-ABC - unit/s
C FE-CO2 - unit/s

D Supervisory Control Valve Asembly - unit/s


Conforming to latest NFPA 13. Refer to Dwg No. FP-
4 for typical detail. Complete with Indicating Type
floor control valve with supervisory switch, system
pressure gauge, water flow switch, inspector test
valve, sight glass, test drain isolation valve and etc
needed to run the system.

ISOLATION VALVES
Conforming to ASME Std and grooved connection
type.
Brand: _________________________
E Ø 100 - pc/s
F Ø 80 - pc/s
G Ø 65 - pc/s
H Ø 50 - pc/s
I Ø 40 - pc/s
J Ø 32 - pc/s
K Ø 25 - pc/s

L Pipe Support & Consumables 1 lot


Conforming to MSS 58 & 69:

FPS System A to L
To Collection
PROP. TWO-STOREY BLDG QNXXXX. 4/4
FIRE PROTECTION SYSTEM THIRD FLR

Item Unit Rate (Php)


Description Qty. Unit Extension (Php)
Materials Others Total
FIRE PROTECTION SYSTEM THIRD FLR
CONTINUATION:
Pendent Type Sprinkler Head (quick response)
Conforming to latest NFPA 13. Refer to Dwg No. FP-
4 for typical detail and FP-1 for specification .

Brand: _________________________
A Pendent Type - pc/s
B Upright type - pc/s
C SideWall type - pc/s

D Riser Nipple or threadolet


Ø 50 - pc/s
Ø 40 - pc/s

E Flushing Connection
Complete with end cap - pc/s

F Pipe Sleeve, for wall & floor penetration 1 lot


Complete with non combustible sealant mineral
wool or equal.
Brand: ___________________________

FPS System A to F
To Collection