You are on page 1of 75

PREPARATION OF BILLS OF Q

USING BESMM 4 AN

BILLS OF QUANTITES DESC

BY Mr. AYOOLA I. OGUNKANMI


PUBLIC BUILDING DEPARTMENT
FEDRAL CAPITAL DEVELOPMENT AUTHORITY

1
GARKI
ABUJA

SUBSTRUCTURE

1.5: EXCAVATING AND FILLING

Removing Trees; (Provisional)


2.1.1 Girth 500 - 1500mm; Filled with laterite Nr.

2.1.2 Girth 1500 - 3000mm; Ditto Nr.

4.1.1 Site Clearance; Clearing Site vegetation and other


growth and dispose off site; entire site Sq.m

5.2.0 Site Preparation; Remove topsoil 150mm deep Sq.m

6.2.1 Excavation, commencing from stripped level; Foundation


excavation; Not exceeding 2m deep Cu.m

Extra Over Foundation excavation; (Provisional)


7.1.3 Excavating in; below ground water level Cu.m

7.2.1 Breaking up; Rock Cu.m

Disposal
9.1.1 Gound Water; 600mm below original ground level Item

9.2.0 Excavated material off site Cu.m

Filling obtained from excavated material


11.1.2 Final thickness of filling not exceeding 500mm deep
500mm thick; Site, not more than 200mm around site,
backfilling foundations; in layers average depth 250mm Sq.m

11.2.2 Final thickness of filling exceeding 500mm deep


500mm thick; Site, not more than 200mm around site,
backfilling foundations; in layers average depth 250mm Sq.m

Graded Laterite

2
12.2.1 Imported Filling; Beds 50mm - 500mm deep 300mm thick;
Level, to falls and cross falls Cu.m

Granite or other equal and approved Hardcore football size

12.2.1 Imported Filling; Beds 50mm - 500mm deep 300mm thick;


Level, to falls and cross falls Cu.m

To Collecton

EXCAVATING AND FILLING (Cont'd)

Approved quality 1mm thick damp proof membrane

16.2.1 Damp Proof Membrane; Over 500mm wide, 1mm thick;


Horizontal Sq.m

1.11: INSITU CONCRETE WORKS

Grade 30 Concrete
1.1.2/1 Mass Concrete; 225mm thick; In trench filling; Poured on or
against earth or unblinded hardcore Cu.m

Weak Concrete (1:10 - graded sub base)


2.1.1/1 Horizontal Work; less or equal to 300 thick; in blinding;
poured on or against earth or unblinded hardcore Cu.m

Grade 25 Concrete
Horizontal Work
2.2.2/2 Over 300mm thick; In structures; Reinforced less or
equal to 5%. Cu.m

5.1.1/1 Vertical Work; less or equal to 300mm thick; in structures;


Reinforced 5% Cu.m

3
Formwork

Plain formwork
Sides of foundations and bases;
13.1.0 less or equal to 500mm high: 450mm wide Lin.m

13.2.0 over 500mm high Lin.m

14.1.0 Edges of horizontal; less or equal to 500mm high: 150mm Lin.m

20.1.0 Sides of isolated Columns 188Nr.; Regular rectangular


shape Sq.m

Reinforcement

High yield steel bars


34.1.2 20mm diameter; Bent; Tonnes

34.1.2 16mm diameter; Bent; Tonnes

34.1.2 10mm diameter; Links Tonnes

37.1.0 Mesh; 4.52kg/sq.m Ref. A152 minimum laps 150mm Sq.m

To Collection

1.14: MASONRY

Brick/Block Walling

Hollow sandcrete blockwall beded and jointed in


cement and sand (1:6)

Walls;
1.2.1/1 225mm thick; blockwork; skin of hollow walls; laid in
stretcher bond Sq.m

Cement and Sand (1:1)

4
16.1.3 Damp Proof Course less or equal 300mm wide; 50mm
thick; Horizontal Lin.m

1.28: FLOOR WALL CEILING AND ROOF FINISHINGS

Cement and sand (1:4) smooth rendering

7.1.0 Plastering to Walls 12mm thick; Less or equal to 600mm Lin.m

1.29: DECORATIONS

Dulux or other equal and approved latex paint one coat;


cement floated wall sandpapered smooth and one coat
of primer on floated wall.

1.2.2 Painting to general surfaces; Over 300mm girth; external Sq.m

To Collection

SUBSTRUCTURE CARRIED TO SUMMARY

FRAMES

1.11: INSITU CONCRETE WORKS

5
Insitu Concrete

Grade 25 Concrete

5.1.1/1 Vertical Work; less or equal to 300mm thick; In structures


Reinforced less or equal to 5% Cu.m

Formwork

Plain

Formwork
20.1.0 Sides of Isolated Columns, 34Nr.; rectangular Sq.m

Reinforcement

High yield steel bars;


34.1.1*2 20mm diameter; Straight and Bent Tonnes

34.1.1*2 16mm ditto Tonnes

34.1.1*2 10mm diameter; Links Tonnes

FRAMES CARRIED TO SUMMARY

6
UPPER FLOORS

1.11: INSITU CONCRETE WORKS

Insitu Concrete

Grade 25 Concrete

Horizontal Work;
2.1.2/2 less or equal to 300mm thick; In structures; Reinforced
less or equal to 5% Cu.m

2.2.2/2 Over 300mm thick ditto Cu.m

Formwork

Plain

Formwork
14.1.0 Edges of Horizontal; Width less or equal to 500mm:
150mm wide Lin.m

Soffits of Horizontal Work;


15.1.1 For concrete less or equal to 300mm thick; Propping

18.1.0 Sides and soffit of attached Beams; Rectangular Sq.m

Reinforcement

High yield steel bars;


34.1.1*2 20mm diameter; Straight and Bent Tonnes

34.1.1*2 16mm ditto Tonnes

34.1.1*2 12mm ditto Tonnes

34.1.1*2 10mm diameter; Links Tonnes

7
UPPER FLOORS CARRIED TO SUMMARY

STAIRCASES

1.11 INSITU CONCRETE WORKS

PLAIN IN SITU CONCRETE REINFORCED

Grade 25 Concrete

2.1.2 Horizontal Works; less or equal to 300mm thick


in Structures Cu.m

4.2.3/2 Sloping Works over 150 ; over 300mm thick; in


staircases; Reinforced less or equal to 5% Cu.m

FORMWORK

Plain formwork

14.1.0 Edges of horizontal; less or equal to 500mm high:


150mm wide Lin.m

15.1.1 Soffits of horizontal works; for concrete less or


equal to 300 thick; propping less or equal to 3m
high Sq.m

25.1.0 Soffit of sloping work; sloping one way Sq.m

26.1.0 Staircase strings and the like; maximum width 380mm Lin.m

27.1.0 Staircase Risers and the like; Vertical 150mm wide Lin.m

8
REINFORCEMENT

High yield steel bars


34.1.1*2 16mm diameter straight and bent Tonnes

34.1.1*2 12mm ditto Tonnes

34.1.1*2 10mm diameter; Links Tonnes

TO COLLECTION

STAIRCASES (Contd)

1.28 : FLOOR WALL CEILING AND ROOF FINISHINGS

Cement and sand (1:4) smooth rendering

Plastering to Walls 12mm thick;


7.2.0 over 600mm wide Sq.m

7.1.0 Less or equal to 600mm Lin.m

600 X 600 X 15mm thick Vitrified Tile

Finish to floors, Vitrified Tiles 50mm thick overall


thickness;
2.1.0 less or equal to 600mm wide Lin.m

2.2.0 Over 600mm wide Sq.m

9
11.1.0/1 Finish to Tread; Net width 300mm; Concrete background Lin.m

12.1.0/1 Finish to Risers; Net width 150mm; Concrete background Lin.m

Cement and Sand (1:6) screeded beds

Screeds, beds and toppings, 40mm thick in one coat


1.1.1/2 less or equal to 600mm wide; Level and to falls only
less or equal to 150 from horizontal; Concrete
background Lin.m

1.2.1/2 Over 600mm wide; Ditto Sq.m

1.29 : DECORATIONS

Dulux or other equal and approved latex paint one coat;


cement floated wall sandpapered smooth and one coat
of primer on floated wall.

Painting to general surfaces;


1.1.1. less or equal to 300mm girth; internal Lin.m

1.2.1 Over 300mm girth; internal Sq.m

1.25: STAIRS, WALKWAYS AND BALUSTRADES

Painted mild steel pipe balustrade

7.1.0 Balustrades; 900mm high comprising 20mm diameter


vertical balusters; 40mm diameter sloping handrail; 6Nr.
20mm diameter intermediate rails; vertical balusters
plugged and screwed to concrete with 6mm thick plate
100 X 100mm Lin.m

To Collections

1.25: STAIRS, WALKWAYS AND BALUSTRADES (Cont'd)

8.1.0 Handrails; 900mm high comprising 20mm diameter


vertical balusters; 40mm diameter sloping handrail; 6Nr.
20mm diameter intermediate rails; vertical balusters
plugged and screwed to concrete with 6mm thick plate
100 X 100mm Lin.m

10
To Collections

STAIRCASES CARRIED TO SUMARY

11
ROOF CONSTRUCTION AND COVERING

1.11: INSITU CONCRETE WORKS

In situ Concrete

Grade 25 Concrete

Horizontal Work
2.2.2/2 Over 300mm thick; In structures; Reinforced less or
equal to 5% Cu.m

4.1.2/2 Sloping over 150 ; less or equal to 300mm thick; In


structures; Reinfored less or equal to 5% Cu.m

Formwork

Plain

formwork
17.1.0 Sides and soffit of isolated beams; Rectangular Sq.m

25.1.0 Soffit of sloping work; Sloping one way; Curved radius


520mm Sq.m

28.2.0 Sloping top surfaces; over 150; Curved radius 520mm Sq.m

14.1.0 Edges of horizontal less or equal to 500mm high: 150mm


wide Lin.m

Reinforcement

High Yield reinforcement Bars


34.1.1*2 12mm diameter; Straight and bent Tonnes

34.1.1*2 Ditto over 12m long: length ……m Tonnes

34.1.1*2 12mm diameter; Curved Tonnes

12
To Collection

1.16: CARPENTRY

Hardwood pressure impregnated with approved


preservatives

Primary or Structural timbers


1.1.1 50 X 150mm; Rafters and associated timbers Lin.m

1.1.3 100 X 150mm; Wall Plates Lin.m

1.1.3/9 Ditto; Length over 6.00 in one continuous length Lin.m

1.1.2 50 X 75mm; Purlins Lin.m

1.1.2/9 Ditto; Length over 6.00 in one continuous length Lin.m

1.1.5/9 50 X 150mm; Beams; Length over 6.00 in one continuous


length Lin.m

1.1.8 50 X 100mm; Strutting Lin.m

1.17: SHEET ROOF COVERING

Sheet Metals

0.7 gauge oven baked corrugated coloured Longspan


Aluminium roofing sheet on Zed Purlins

1.2.3 Covering over 500mm wide; Sloping 300 Pitch; oven baked
coloured Sq.m

Boundary work;
4.1.2/1 200mm girth; Eaves; Horizontal Lin.m

13
4.1.3/1 350mm girth; Ridges; Lin.m
Horizontal

4.1.5/1 350mm girth; Valleys; Sloping Lin.m

4.1.6/1 350mm girth; Hips; Sloping Lin.m

To Collection

1.15: STRUCTURAL METALWORK (Provisional)

Framed members, framing and fabrication


1.1.1/4 Length not exceeding 1.00m;
weight less or equal to 25Kg/m; Bracings Tonnes

1.1.2/4 Weight 25 - 50Kg/m; Bracings Tonnes

1.2.2/3 Lengths 1.00 - 9.00m;


Weight 25 - 50Kg/m; Rafters Tonnes

1.2.2/2 Ditto; Beams Tonnes

5.2.1. Allowance for fittings: Percentage Allowance: 20%; To


framed members Tonnes

6.1.1/1 Cold Rolled Purlins, cladding rails and the like:


Zed purlins bolted to 125 X 75 x 8mm 150mm long
angle cleat welded to structural member; 150 X 50 x2mm
Purlins Lin.m

14
6.1.2/1 16mm diameter high tensile steel welded to Purlins:
Sag Rods Lin.m

10.1.1 Holding down assemblies; 6mm thick base plate holding


4Nr. 24mm diameter one side threaded and other end
fish tailed rag bolts complete with nuts and washers
embedded in concrete. Nr.

Berger paint or other equal and approved

15.3.1/2 Surface Treatment; painting; On site; One primer and


two coats of red oxide Sq.m

To Collections

INTERNAL AND EXTERNAL WALLS

1.11 INSITU CONCRETE WORKS

In Situ Concrete

Grade 25 Concrete in Superstructures

Plain In Situ Concrete Reinforced

15
2.1.2/2 Horizontal work; Less or equal to 300mm thick;

16
In structures; Reinforced less or equal to 5% Cu.m

Formwork - Plain formwork

17.1.0 Sides and soffit of isolated beams; Regular rectangular


shape Sq.m

Reinforcement

34.1.1*2 High yield steel bars; 12mm diameter; Straight and Bent Tonnes

34.1.1*2 Ditto; Bars exceeding 12m long Tonnes

1.14 MASONRY
BRICK/BLOCK WALLING

225mm thick Hollow sandcrete blockwall bedded and


jointed in cement mortar (1:6) and laid in stretcher
bond

1.2.1 Walls overall thickness 225mm; Blockwork; Skin of


hollow walls; laid in wall Sq.m

1.2.1 Ditto 150mm ditto Sq.m

INTERNAL AND EXTERNAL WALL CARRIED TO SUMMARY

17
WINDOW

1.23: WINDOWS SCREENS AND LIGHTS

Nigalex or other equal and approved heavy gauge


aluminium section two or three bays with net; factory
glazed with tinted 4mm thick sheet glass complete with
glazing beads and other accessories and ironmongery
including screwing and plugging frames to blockwall
and concretework to Architects drawings

Windows and window frames


1.1.0/2 1200 X 1200mm high Nr.

1.1.0/2 1500 X 1500mm high Nr.

1.1.0/2 600 X 600mm high Nr.

1.26: METAL WORK

Isolated Metal Member

Burglar Bars comprising 50 X 25 X 2mm thick surround;


25 X 25 X 2mm thick vertical bars at 150mm intervals
welded to surround bar and 25 X 25 X 2mm thick
horizontal bars welded to surround bar and vertical
at 300mm intervals including drilling holes in concrete
or blockwork and fixing burglar bars to concrete with
12mm diameter high tensile hold bar driven in concrete
or blockwork complete with painting in red oxide and
finishing in gloss paint

Composite Items
5.1.1/1 Ditto 1200 X 1200mm high; welded on 150mm long 12mm
diameter bar drilled and driven into wall Nr.

5.1.1/1 Ditto 1500 X 1500mm high; ditto Nr.

5.1.1/1 Ditto 600 X 600m high; ditto Nr.

18
WINDOWS CARRIED TO SUMMARY

DOORS

Doors and Frames

44mm thick polished seasoned solid core fluch doors


lipped on all edges with hardwood and faced on both
sides with quality plywood complete with door lining
architraves and all necessary ironmongery

Door Sets
1.1.1 To fit opening size 900 X 2100mm high; blocwall Nr.

1.1.1 Ditto 750 X 2100mm high; blockwall Nr.

Purpose made swing doors constructed of hollowsteel


sections and steel plates complete with frames and glazing
comprising of 4mm thick clear sheet glass and beads
including all necessary ironmongery

Door Sets
1.1.1 To fit opening size 1800 X 2100mm high; blockwall Nr.

1.1.1 Ditto 1200 X 2100mm high; blockwall Nr.

19
DOORS CARRIED TO SUMMARY

WALL FINISHINGS

1.28: FLOOR WALL CEILING AND ROOF FINISHINGS

Cement and sand (1:4) smooth rendering

Plastering to Walls 12mm thick;


7.2.0 over 600mm wide Sq.m

7.2.1 Less or equal to 600mm Lin.m

7.2.0 over 600mm wide externally Sq.m

7.2.1 Less or equal to 600mm externally Lin.m

Plastering to isolated columns 12mm thick


8.2.0 over 600mm wide Sq.m

Plastering to isolated beams 12mm thick


10.2.0 over 600mm wide Sq.m

10.1.0 Less or equal to 600mm Lin.m

7.2.0 Tiles to wall 10mm thick; over 600mm wide Sq.m

1.29: DECORATIONS

20
Dulux or other equal and approved latex paint one coat;
cement floated wall sandpapered smooth and one coat
of primer on floated wall.

Painting to general surfaces;


1.1.1 less or equal to 300mm girth; internal Lin.m

1.2.1 Over 300mm girth; internal Sq.m

1.1.2 less or equal to 300mm girth; external Lin.m

1.2.2 Over 300mm girth; external Sq.m

WALL FINISHING CARRIED TO SUMMARY

FLOOR FINISHINGS

Cement and Sand screeded bed

1.1.1/1*2 Screeds, beds and topping 40mm thick in one coat;


less or equal to 600mm wide; Level and to falls only
less or equal to 150 from horizontal; Vitrified Tiles
surface; Concrete background Lin.m

1.2.1/1*2 Over 600mm wide; Level and to falls only less or equal
to 150 from horizontal; Vitrified Tiles surface; concrete
background Sq.m

600 X 600 X 15mm thick Vitrified Tile

Finish to floors, Vitrified Tiles 50mm thick overall

21
thickness;
2.1.0 less or equal to 600mm wide Lin.m

2.2.0 Over 600mm wide Sq.m

14.1.0/1 Skirtings, net height 100mm; 15mm wide; Blockwall


background Lin.m

300 X 300 X 10mm thick Vitrified Tile

Finish to floors, Vitrified Tiles 50mm thick overall


thickness;
6.1.1. less or equal to 600mm wide; Level and to falls only
less or equal to 150 from horizontal. Lin.m

6.2.1 Over 600mm wide; ditto Sq.m

FLOOR FINISHING CARRIED TO SUMMARY

CEILING FINISHINGS

1.28: FLOOR WALL CEILING AND ROOF FINISHINGS

Cement and Sand (1:4) rendering

22
9.1.0 Finishing to ceiling, plastering 12mm thick; over 600mm
wide Sq.m

600 X 600 X 20mm thick acoustic mineral fibre suspended


ceiling in aluminium grid bearer

9.1.0 Finishing to ceiling, acoustic ceiling tiles 20mm thick;


over 600wide Sq.m

Dulux or other equal and approved latex paint one coat;


cement floated wall sandpapered smooth and one coat
of primer on floated wall.

1.2.1. Painting to general surfaces; Over 300mm girth; internal Sq.m

CEILING CARRIED TO SUMMARY

23
1.38: MECHANICAL SERVICES

Rainwater Disposal System

Mutunci or other equal and approved uPVC pipe

3.1.1 Pipework; Straight; 100mm diameter uPVC; socket


and spigot joint; fixed to concrete with matching
stainless steel bracket; Lin.m

Pipe Fittings; 100mm diameter pipe; socket and spigot


joint
4.4.2 Bend Nr.

4.4.2 450 Bend Nr.

5.8.1 Shoes Nr.

5.7.1 Pipe ancillaries; Fulbora or other equal and approve outlet;


uPVC, 100mm diameter, socket and spigot joint. Nr.

Cold Water Supply System

Rifeng or other equal and approved multi layer pipe

3.1.1/1 Pipework; Straight; 20mm diameter; jointed to


manufacturers instructions; fixed in concrte or blockwork
chases Lin.m

Pipe Fittings; 20mm diameter pipe; jointed to manufacturer's


instructions
4.4.2 Bends Nr.

4.5.2 Tees Nr.

4.2.2 20/12mm bushing Nr.

5.1.1 Valve Nr.

5.1.1 Pipe Fittings; 12mm diameter pipe; jointed to manufacturer's


instructions; Angle Valve Nr.

24
To Collection

MECHANICAL SERVICES (Cont'd)

Cold Water Supply System (Cont'd)

Tigre or other equal and approved uPVC pipe

3.1.1/1 Pipework; Straight; 25mm diameter uPVC; diced and


screwed in joint with cement material and yarn rope;
fixed to duct with matching stainless steel bracket. Lin.m

Pipe Fittings; 25mm diameter pipe; jointed as before


described
4.4.2 Bend Nr.

5.1.1 Heavy Gauge Bronze cast Valves Nr.

4.1.2 Union Connector Nr.

4.2.2 Nipples Nr.

Jointing to multi layered pipe Nr.

Hot Water Supply System

Rifeng or other equal and approved multi layer pipe

3.1.1/1 Pipework; Straight; 20mm diameter; jointed to


manufacturers instructions; fixed in concrte or blockwork
chases Lin.m

Pipe Fittings; 20mm diameter pipe; jointed to manufacturer's

25
instructions
4.4.2 Bends Nr.

4.5.2 Tees Nr.

4.2.2 20/12mm bushing Nr.

5.1.1 Pipe Fittings; 12mm diameter pipe; jointed to manufacturer's


instructions; Angle Valve Nr.

To Collection

MECHANICAL SERVICES (Cont'd)

Waste Disposal System

Supply and install the following sanitary fitting


manufactured by Twyford or other equal and approved

Terminal Equipment and fitting


2.1.1/1 White vitreous China Water Closet Suite comprising
Tank with flushing mechanism; Bowl plugged and
screwed to floor with matching screws including seat
and cover and pan connector. Nr.

2.1.1/1 White Vitreous China Wash Hand Basin complete with


chrome plated waste with chain and black rubber stay
Chrome plated bib tap with hot and cold water discharge
ability and uPVC white bottle trap Nr.

2.1.1/1 White Vitreous enamel coated shower tray with

26
chrome plated waste and P trap; Chrome plated shower
rose and pipe fixed to wall with clip plugged and
screwed Nr.

2.1.1/1 Toilet roll Holder plugged and screwed Nr.

2.1.1/1 900mm long chrome plated towel rail pluigged and


screwed Nr.

2.1.1/1 450 X 600 X 10mm thick silver backed mirror Nr.

Ariston or other equal and approved

2.1.1/1 Primary equipment; 50 liter water Heater hanged on wall Nr.

To Collection

Waste Disposal (Cont'd)

Mutunci or other equal and approved uPVC pipe

3.1.1./1 Pipework; Straight; 100mm diameter uPVC; socket


and spigot joint; fixed to concrete with matching
stainless steel bracket; Lin.m

27
Pipe Fittings; 100mm diameter pipe; socket and spigot
joint
4.4.2 Bend Nr.

4.8.2 Reducer Bend Nr.

4.4.2 450 Bend Nr.

4.5.2 Tees Nr.

4.8.2 Reducer Tees Nr.

3.1.1/1 Pipework; Straight; 50mm diameter uPVC; socket and


spigot joint; fixed to concrete with matching stainless
steel bracket; Lin.m

Pipe Fittings; 50mm diameter pipe; socket and spigot


joint
4.4.2 Bend Nr.

4.8.2 450 Bend Nr.

4.5.2 Tees Nr.

To Collection

28
Fire Hose Reels

Groundfos or other equal and approved

1.1.1./1 Primary equipment ; Fire fighting system; Fire pumps

Nr.
ABC or other equal and approved fire hose reel

2.1.1/1 Terminal Equipment and Fittings; Swing Arm Fire Hose


Reels; Wall mount Cabinet type in red with 36m X 19mm
fire fighting nozzle; high or low level on floors Nr.

Heavy Gauge Gavanised iron pipe painted red with gloss


paint

3.1.1/1 Pipework; Straight; 32mm diameter uPVC; diced and


screwed in joint with cement material and yarn rope;
fixed to duct with matching stainless steel bracket. Lin.m

Pipe Fittings; 32mm diameter pipe; jointed as before


described
4.4.2 Bend Nr.

4.4.2 450 Bend Nr.

4.8.2 Reducer Bend Nr.

4.5.2 Tees Nr.

5.1.1 Heavy Gauge Bronze cast Valves Nr.

4.2.2 Union Connector Nr.

4.2.2 Nipples Nr.

29
To Collection

MECHANICAL SERVICES (Cont'd)

Air conditioning

Mutunci or other equal and approved uPVC pipe

3.1.1/1 Pipework; Straight; 75mm diameter uPVC; socket


and spigot joint; Laid in chases Lin.m

Pipe Fittings; 100mm diameter pipe; socket and spigot


joint
4.4.2 450 Bend Nr.

17.0.0 Testing Item

18.0.0 Commisioning Item

21.0.0 Drawing Preparation; Installation, Coordination, as


installed, and record drawings Item

To Collection

30
ELECTRICAL INSTALLATION

Incoming Services

Merlin Gerin, Schneider or other equal and approved

Primary Equipment
1.1.1/1 Coloured oven baked metal clad Main Distribution
Panel 800A T,P & N; One incoming 800A Rating; 4Nr
200A outgoing, 3Nr. 60A outgoing and 60A spare
complete with all accessories; Low level in plant room Nr.

Terminal equipment
2.1.1/1 Coloured oven baked metal clad Low Voltage
Distribution Panel 200A T P & N; One incoming 200A
Rating; 6Nr. Outgoing and 1Nr. Spare rating 60A
complete with MCCB, 200A T P & N Isolator Switch
and other accessories; Low level on floors Nr.

2.1.1/1 Change Over Switch 800A T P & N Nr.

1.2.0 Offload and position of primary equipment Nr.

31
1.3.0 Assembly of composite items of prmary equipment Nr.

Nocaco or other equal and approved

Cables
3.1.1/1 Armoured cable 240sq.mm 4 core copper pvc/swa/pvc
jointed in running length to manufacturer's details;
low level in plant room and on floor
In trenches (Provisional) Lin.m

3.1.1/1 In sleeves Lin.m

3.1.1/1 In trunk (Provisional) Lin.m

Armoured cable 70sq.mm 4 core copper pvc/swa/pvc


jointed in running length to manufacturer's details;
low level in plant room and on floor
3.1.1/1 In trenches Lin.m

3.1.1/1 In sleeves Lin.m

To Collection

Incoming Services (Cont'd)

Cables (cont'd)
Armoured cable 10sq.mm 4 core copper pvc/swa/pvc
jointed in running length to manufacturer's details;
low level in plant room and on floor
3.1.1/1 In trenches Lin.m

3.1.1/1 In sleeves Lin.m

3.1.1/1 In trunk Lin.m

Armoured cable 16sq.mm 4 core copper pvc/swa/pvc

32
jointed in running length to manufacturer's details;
low level in plant room and on floor
3.1.1/1 In trenches Lin.m

3.1.1/1 In sleeves Lin.m

3.1.1/1 In trunk Lin.m

AEI Cables Limited or other equal and approved

Cable Terminations and Joints


6.0.1 Outdoor type, 800A 240sq.mm 4 core bronze material
armoured pvc/swa/pvc Nr.

6.0.1 Outdoor type, 200A 70sq.mm 4 core bronze material


armoured pvc/swa/pvc Nr.

6.0.1 Indoor type ditto Nr.

6.0.1 Outdoor type, 60A 10sq.mm 4 core bronze material


armoured pvc/swa/pvc Nr.

6.0.1 Indoor type, 60A 10sq.mm 4 core bronze material


armoured pvc/swa/pvc Nr.

6.0.1 Indoor type, 60A 16sq.mm 4 core bronze material


armoured pvc/swa/pvc Nr.

To Collection

Cable Containment

33
3.0.1/1 Galvanised sheet cable trunk with cover rectangular
shape 250 X 75mm thick with three compartments
jointed as may be directed by the Engineer plugged
and screwed to wall; risers Lin.m

3.0.1/1 Ditto; low level on floors Lin.m

Final Circuits

ABB or other equal and approved plugged and screwed


to wall

Primary Equipment
1.1.1/1 60A 6 Ways T P & N metal clad Distribution Board
with miniature circuit breakers and 60A ELCB Nr.

1.1.1/1 60A 4 Ways Nr.


ditto

Nocaco or other equal and approved single core wire


drawn in 20mm diameter Mutunci or other equal and
approved conduit pipe in chases

Final circuits
7.0.1 PVC copper cable with 10A rating 1.5sq.mm size in
18Nr. Lighting points Nr.

7.0.1 Ditto 22Nr. Ditto Nr.

7.0.1 Ditto 11Nr. Ditto Nr.

7.0.1 Ditto 25Nr. Ditto Nr.

7.0.1 Ditto 21Nr. Ditto Nr.

7.0.1 Ditto 17Nr. Ditto Nr.

7.0.1 Ditto 19Nr. Ditto Nr.

7.0.1 Ditto 15Nr. Ditto Nr.

7.0.1 Ditto 14Nr. Ditto Nr.

7.0.1 Ditto 20Nr. Ditto Nr.

To Collection

34
Nocaco or other equal and approved single core wire
drawn in 20mm diameter Mutunci or other equal and
approved conduit pipe in chases

Final circuits
PVC copper cable with 30A rating 2.5sq.mm size in
ring circuit
7.0.1 11Nr. 13A Switched socket outlet Nr.

7.0.1 13Nr. Ditto Nr.

7.0.1 12Nr. Ditto Nr.

7.0.1 9Nr. Ditto Nr.

7.0.1 8Nr. Ditto Nr.

7.0.1 7Nr. Ditto Nr.

7.0.1 10Nr. Ditto Nr.

PVC copper cable with 20A rating 4.0sq.mm size in


7.0.1 1Nr. 15A Switched socket outlet Nr.

7.0.1 1Nr. Water Heater Nr.

ABB or other equal and approved accessories

Terminal Equipment
2.1.1 10A One Gang one Way Switch Nr.

2.1.1 10A One Gang Two Way Switch Nr.

2.1.1 10A Two Gang one Way Switch Nr.

2.1.1 10A Two Gang Two Way Switch Nr.

2.1.1 10A Three Gang one Way Switch Nr.

35
2.1.1 10A Three Gang Two Way Switch Nr.

2.1.1 20A Intermediate switch Nr.

2.1.1 13A switched Socket Outlet Nr.

2.1.1 13A Twin switched Socket Outlet Nr.

To Collecton

Scolmore Ltd or other equal and approved Luminaires

Terminal Equipment
2.1.1 1 X 40W Screwneck ceiing mounted Lighting fitting
with diffuser Nr.

2.1.1 40W Recessed Fitting Nr.

2.1.1 1 X 36W 1.2m fluorescent fitting with pristmatic


transparent diffuser Nr.

2.1.1 1 X 100W Bulkhead fitting with transparent diffuser Nr.

2.1.1 60W Wall mounted lighting fitting with pristmatic


diffuser. Nr.

2.1.1 15A Socket Outlet Nr.

2.1.1 SMC or other equal and approved 1200mm sweep


ceiling Fan complete with regulator Nr.

Fire Alarm system

Gents or other equal and approved

Primary Equipment
1.1.1/1 Vigilon Analogue 3 Loop Addressable Fire Alarm Panel
High level on floors Nr.

36
Nocaco or other equal and approved single core wire
drawn in 20mm diameter Mutunci or other equal and
approved conduit pipe in chases

Final circuits
7.0.1 PVC copper cable with 10A rating 1.0sq.mm size in
87Nr. Points comprising 51Nr. Optical smoke detector,
18Nr. manual break call bells and 18Nr. Fire alarm call
Bell Nr.

Gents or other equal and approved

Terminal Equipment
2.1.1 Addressable Optical Smoke Detector Nr.

2.1.1 Manual Break Call Bell Nr.

2.1.1 Addressable Fire Alarm Call Bell Nr.

To Collection

Lightening and Earthing System

Indelec or other equal and approved

Electrodes, Earth Rods Air Terminations, bars


12.0.1 Prevectron 3 S40 Early Steamer Emission Air Terminal
Lightening conductor Nr.

12.0.1 Chromium plated copper M20 tapered threaded wall


Air Rod lightening arrestor Nr.

12.0.1 Highly conductive copper coated stainless steel pointed


Copperbound Earth Rod 2400mm deep 17.2mm diameter
in inspection house Nr.

Indelec Lightening Protection system conductor

37
Tapes
11.0.1/1 Tinned Copper tape conductors 25 X 3mm thick
Roofs Lin.m

11.0.1/1 Risers Lin.m

11.0.1/1 Trenches Lin.m

Nocaco or other equal and approved

Cables; 6 sq.mm PVC sheath single core copper cable


5.0.1/1 low level in floors Lin.m

5.0.1/1 In trenches Lin.m

5.0.1/1 In trunks Lin.m

15.0.0 Testing Item

16.0.0 Commissioning Item

19.0.0 Drawing Preparation; Installations, Coordination, as


installed and record drawings Item

21.1.0 Loose Ancillaries; Keys, tools, spares, chemicals Item