You are on page 1of 2

TM

DReeM Polymer for Boiler


New Scale Preventing Chemicals for Boiler Water System
Keeping High Efficiency of Boilers !

Dispersion and Removal effects Management Polymer for Boiler

KURITA has developed


tableS Stable boiler water treatment with
• Strong performance to prevent scaling of hardness
“DReeM Polymer” to keep • Optimum pH control and oxygen scavenging effect
high efficiency of boiler !
S ecure
Secure operation with
Scale problem leads to • Scale removing effect while normal operation
• No corrosive effect to boiler tube itself
loss of energy and tube
rupture.
Let’s solve it together!!
S avings
Saving cost and labor with
• Clean heat transfer surface and keeping high efficiency
• No additional cleaning agent

Field application result


Inspection result of small once through boiler Conventional polymer treatment
N= 6, SiO2 = 350 mg/L
Initial condition ( 16 Feb )

DReeM Polymer treatment


N= 12, SiO2 = 700 mg/L
After 3 months application ( 10 May )

Upper side 30cm 70cm 110cm 150cm Bottom side

1
F eatures
● Strong dispersion performance to hardness leaked into boiler feed water
● Removing scale while normal operation, even if scale happen to occur with excess hardness
● No corrosive effect to heat transfer tubes

KURITA AX Series Specifications


AX – P series AX – 4 series AX – E series
KURITA KURITA KURITA KURITA KURITA KURITA
AX-730P AX-734P AX-7214 AX-7234 AX-421E AX-404E
Boiler type Water tube boiler, Fire tube boiler, small once-through boiler
Application

Pressure Maximum 2.0 MPa *1


Feed water Softened water, Demineralized water, RO treated water
M-Alk*2 in Feed
High Low High Low High Low
water
pH control ○*3 ○*3 ○*3
Function

Scale dispersing
◎*3 ◎*3 ◎*3
& removing
Oxygen scavenging -*3 ○*3 ○*3
Ingredients Consist from chemicals listed in FDA standard
Appearance Light yellow to Light pink Dark brown to Black Light brown to Dark brown
Blow-down color Clear to light Yellow Light brown to Black Clear to Light brown

*1 If the pressure of boiler exceeds this value, consult with Kurita’s specialists.
*2 M-alkalinity
*3 ◎: Excellent, ○: Good, -: No function

Handling And Storage In case of skin contact, wash thoroughly with water. If
Keep out of reach of children. For industrial use only. eyes are affected, flush with water and get medical
Harmful if inhaled. Avoid breathing vapors. Keep attention.
containers closed when not in use. Causes eye injury
and skin irritation on direct contact. Wear goggles Packaging
and rubber gloves when handling. Standard Packing

Realize a true safety and efficient boiler water treatment with us !!