SCHEDULE OF SLABS SCHEDULE OF BEAMS

THK R E I N F O R C E M E N T LEFT SUPPORT MIDSPAN RIGHT SUPPORT DIMENSION BAR Ø MIDDLE STIRRUPS
MARK PARALLEL TO SHORT SPAN PARALLEL TO LONG SPAN REMARKS MARK B x D (mm) (mm)
(mm) BAR
TOP BOTTOM TOP BOTTOM TOP BOTTOM
@ SUPPORT @ MIDSPAN @ SUPPORT @ MIDSPAN
ROOF BEAMS
TB 12mmØ @ 200 mm O.C. TB 12mmØ @ 200 mm O.C.
S-1 120 TWO - WAY RB-1 4 2 2 4 4 2 200 x 350 16 mm A
BB 12mmØ @ 400 mm O.C. 12mmØ @ 200 mm O.C. BB 12mmØ @ 400 mm O.C. 12mmØ @ 200 mm O.C.
RB-2 3 2 2 3 3 2 200 x 350 16 mm A
TB 12mmØ @ 200 mm O.C.
S-2 120 ONE - WAY RCB-1 4 2 4 2 200 x 350 16 mm A
BB 12mmØ @ 400 mm O.C. 12mmØ @ 200 mm O.C. BB 10mmØ @ 300 mm O.C. 10mmØ @ 300 mm O.C.
DB-1 5 2 2 5 5 2 200 x 400 16 mm 2-12 mm A
DB-2 4 2 2 4 4 2 200 x 400 16 mm A
SECOND FLOOR BEAMS
B-1 5 2 2 5 5 2 200 x 400 16 mm 2-12 mm A
B-2 4 2 2 4 4 2 200 x 400 16 mm A
CB-1 5 2 5 2 200 x 400 16 mm 2-12 mm A
CB-2 4 2 4 2 200 x 400 16 mm A
GROUND FLOOR BEAMS
FTB-1 2 2 2 2 2 2 200 x 300 16 mm A
STIRRUPS "A" 10mm. Ø 4 @ 50mm., 4 @ 100mm., 2 @ 150mm., REST @ 200mm. O.C.

GRID GRID
L/4 L/4 CANTILEVER BEAM

"B"
TOP BARS TOP BARS
TOP BARS
ADD'L LEFT CONTINUOUS
ADD'L RIGTH
TOP BARS

WEB BARS

"D"
BOT. BARS
BOTTOM BARS BOTTOM BARS
CONTINUOUS ADDITIONAL

50 50 STIRRUPS 50 50

S/2 S/4
TYP. SECTION
L/5 L/5
S (SHORT SPAN )

TYP. ELEVATION OF BEAM ALONG COLUMN LINES


ONE WAY SLAB TWO WAY SLAB
SCHEDULE OF FOOTINGS
THK SIZE (m) BOTTOM BARS DEPTH OF
MARK REMARKS
(mm) WIDTH LENGTH BAR 'S' BAR 'L' EXCAVATION (m)
F-1 300 1.50 1.50 8 - 16mmØ 8 - 16mmØ ± 1.50 ISOLATED FOOTING
F-2 300 1.20 1.20 7 - 16mmØ 7 - 16mmØ ± 1.20 ISOLATED FOOTING
F-3 275 0.85 0.85 7 - 12mmØ 7 - 12mmØ ± 1.50 ISOLATED FOOTING
F-2 275 0.80 0.65 6 - 12mmØ 6 - 12mmØ ± 1.50 ISOLATED FOOTING

NOTE: NO FOOTING'S REST ON BACKFILL MATERIALS

MINIMUM SPLICE LENGTH


BEAMS COLUMNS
BAR SIZE
TOP BARS BOTTOM BARS VERTICAL BARS

20mmØ 800mm 800mm 700mm

16mmØ 650mm 650mm 600mm

12mmØ 500mm 500mm 400mm

10mmØ 400mm 400mm 300mm

REPUBLIC ACT NO. 9266 PROJECT TITLE: OWNER: SHEET CONTENTS: CADD BY: SHEET NO:
Drawings and specifications duly signed, stamped or DESIGN BY:
sealed, as instruments of service, are the intellectual
properties and documents of the architect, whether
the object for which they are made is executed or not.
PROPOSED TWO (2) - STOREY SCHEDULE OF SLAB
SCHEDULE OF BEAM
CHECKED BY: S
architectural designs It shall be unlawful for any person, without the consent SINGLE-DETACHED RESIDENTIAL BUILDING APPROVED BY:
of the architect or author of said documents to SCHEDULE OF FOOTING
duplicate or to make copies of said documents for use ANDREW C. ONGTECO GENERAL SPECIFICATIONS
(+63922) 8011682,
52 Marvex Drive, Balintawak, QC.
in the repetition of and for other projects or buildings,
whether executed partly or in whole. LOCATION: TAAL CRYSTAL ESTATE ALFONSO, CAVITE
REVISION:

DATE:
1

You might also like