You are on page 1of 4

SUMMARIES OF THE ANALYSIS AND DESIGN

8.1 COLUMN OUTPUT:


Concrete Grade: M25
Steel Grade: Fe 500
Clear Cover: 40 mm

Fig.6.7
Column ID Size (mm) Up to Ground floor Up to 1st Floor 2nd floor to Eve

C1 350X350 4-20ф+4-16ф 4-16ф+4-16ф 4-16ф+4-12ф


C2 350X350 4-20ф+4-20ф 4-20ф+4-16ф 4-16ф+4-12ф

NOTE:
1. The transverse reinforcement in the column should be 8mm ф, 4- legged @ 100mm c/c at below and
above the face of the beam for a distance of 0.8m.
2. The spacing of 8mm ф, 4- legged transverse reinforcement should be @ 100mm c/c in lap zone.
3. Other detailing is as per structural drawings sheet.
8.2 BEAM OUTPUT:
Design Parameters: Concrete Grade: M20
Steel Grade: Fe 500
Clear Cover: 30 mm
Beams Rebars at Support Rebars at mid span
Top Bottom Top Bottom
Plinth Beam 3-16mm dia. Bars 3-16mm dia. Bars 3-16mm dia. Bars 3-16mm dia. Bars
(250x300mm) (TH) (TH)
First Floor Beam
MB (250x425mm) along 3-20mm dia. Bars 3-20mm dia. Bars 3-20mm dia. Bars 3-20mm dia. Bars
Grid 1, 2 & 3 (TH) +2-16mm (EX) (TH)

MB (250x425mm) along 3-16mm dia. Bars 3-16mm dia. Bars 3-16mm dia. Bars 3-16mm dia. Bars
Grid A, B, C & D (TH) +2-16mm (EX) (TH)

SB (250x355mm) 2-16mm dia. Bars 3-20mm dia. Bars 2-16mm dia. Bars 3-20mm dia. Bars
(TH) (TH)

Second Floor Beam


MB (250x425mm) along 3-16mm dia. Bars 3-20mm dia. Bars 3-20mm dia. Bars 3-20mm dia. Bars
Grid 1, 2 & 3 (TH) +2-16mm (EX) (TH)

MB (250x425mm) along 3-16mm dia. Bars 3-16mm dia. Bars 3-16mm dia. Bars 3-16mm dia. Bars
Grid A, B, C & D (TH) (TH)

SB (250x355mm) 2-16mm dia. Bars 3-16mm dia. Bars 2-16mm dia. Bars 3-16mm dia. Bars
(TH) (TH)
Stair Cover
MB (250x425mm) 2-16mm dia. Bars 2-16mm dia. Bars 2-16mm dia. Bars 2-16mm dia. Bars
(TH) (TH)

SB (250x355mm) 2-16mm dia. Bars 2-16mm dia. Bars 2-16mm dia. Bars 2-16mm dia. Bars
(TH) (TH)

Vertical Stirrups 8mm dia. Vertical Stirrups @ 100mm c/c 8mm dia. Vertical Stirrups @ 150mm c/c
upto L/4 from end of support upto midspan

NOTE:
At Grid 2-2, between Grid B-B & C-C, provide bottom reinforcement in two layers.

1. The shear reinforcement in the L/4 of beam span measured from supports face should be 8mm ф
provided @ 100mm c/c and can be placed @ 150mm c/c in remaining span.
2. The shear reinforcement in the main beam in which secondary beams are tied should be 8mm ф
provided @ 75mm c/c throughout.
3.The shear reinforcement in the lapping zone should be also provided @ 150mm c/c
4.The shear reinforcement in the circular beam should be provided @ 100mm c/c
8.3 FOOTING OUTPUT

SUMMARISE OF THE ISOLATED FOOTING WITH ITS DETAILINGS ARE AS FOLLOWS


Schedule of RCC Footing- SBC 120 KN/m2

Footing Footing size Footing type Depth Top Bottom


mm (L x B) of
footing footing Rebar along footing Rebar along
Length & Breadth Length & Breadth
F1 1530 X 1530 Isolated 450 mm 12mm dia@150mmc/c 12mm dia@150mmc/c
F2 2000 X 2000 Isolated 450 mm 12mm dia@150mmc/c 12mm dia@150mmc/c
F3 2200X 2200 Isolated 450 mm 12mm dia@150mmc/c 12mm dia@150mmc/c
F4 2600X 2600 Isolated 600 mm 12mm dia@150mmc/c 12mm dia@150mmc/c
8.4 SLAB REINFORCEMENT: SLAB THICKNESS – 150mm
Main bar 10 mm and extra bar 8 mm @ 150 mm C/C.

8.5 CANTILEVER SLAB REINFORCEMENT: SLAB THICKNESS – 125mm


Main bar 12 mm and extra bar 10 mm @ 150 mm C/C.

8.6 Staircase Bar: WAIST SLAB THICKNESS – 150mm


Use 12mm dia. bar as main bar @ 150 mm C/C and 10 mm as distribution bar @ 200 mm C/C.

Required sizes of structure were adopted


SN Structures Sizes(mm)
1 Column (350mmX350mm)
2 Main Beam MB (250mm X 425mm)
SB (250mm X 355mm)
3 Slab 150mm

4 Concrete grade M25 Column, M20 Beam,


Footing and Slabs
5 Steel grade Fe500 for main bar and
Fe450 (stirrups)