m4w en Ma Drw170802aa 20171218 He 20171226-3
m4w en Ma Drw170802aa 20171218 He 20171226-3
Power of
※1
A
-0.50~1.00~ Load
the load
INSTRUCTION MANUAL Max. display range Max. 1999
+0.50cosø
Measurement function AC voltage DC voltage AC current DC current AC watt rpm Speed Scaling meter Power factor HI LOW HI LOW
Power supply 110/220VACᜠ 50/60Hz(Option:100-240VACᜠ 50/60Hz, 24-70VDCᜡ)
Voltmeter Ammeter
Allowable voltage range 90 to 110% of rated voltage
Power consumption M4W-DC: 2W, AC: 4VA / M4W1P, 2P-DC: 3W, AC: 5VA
Display method 7Segment LED Display(Charachter height: 14mm) DC power DC power
Sampling cycle 300ms supply 1 supply 2
A/D conversion method Dual slope intergal method
Response time 2sec(0 to Max.) ※1: Compared to measurement input range, higher measuring voltage needs a multiplier
Sampling times 2.5 times/sec and lower measuring voltage needs a shunt.
※When using voltmeter and ammeter simultaneously, connect the separated power
Insulation resistance Over 100MΩ(at 500VDC megger)
supply each.
Dielectric strength 2000VAC 50/60Hz for 1 minute ※(-) terminal of the power and (-) terminal of measurement input are shorted.
Noise immunity ±1kV the square wave noise(pulse width:1㎲) by the noise simulator
Thank you for choosing our Autonics products.
Please read the following safety considerations before use. Vibration
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z directions for 1 hour For AC power supply
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z directions for 10 minutes
Mechanical 300m/s²(approx. 30G) in each X, Y, Z direction for 3 times ※1
Shock
A
Safety Considerations Malfunction
Ambient temperature
100m/s²(approx. 10G) in each X, Y, Z direction for 3 times
-10 to 50℃, storage: -25 to 65℃
Power of
the load
Load
Environ
-ment Ambient humidity 35 to 85%RH, storage: 35 to 85%RH HI LOW HI LOW
※Please observe all safety considerations for safe and proper product operation
to avoid hazards. Relay Mechanical Min. 10,000,000 times
life cycle Electrical Min. 100,000 times(250VAC 3A resistive load) Voltmeter Ammeter
※Safety considerations are categorized as follows.
Output capacity M4W: Non, M4W1P: Relay contact output 250VAC 3A 1c, M4W2P: Relay contact output 250VAC 3A 1c×2
Warning Failure to follow these instructions may result in serious injury or death. F.S. ±3% rdg
AC power
Display accuracy DC: F.S. ±0.2% rdg ±1Digit 23℃ ±5℃, AC: F.S. ±0.5% rdg ±2Digit 23℃ ±5℃ F.S.±0.3% rdg ±1Digit 23℃ ±5℃ supply
±1Digit
Failure to follow these instructions may result in personal injury
Caution or product damage. Unit weight M4W: Approx. 168g, M4W-P: Approx. 268g, M4W1P: Approx. 253g, M4W2P: Approx. 278g