You are on page 1of 1

TIilULTIVECTOR REVIEW AND TRAINING CENTER

POWER PI.ANT
- $ePt 2002
REE
and with a head of 235 m'
-A
10. power plant is driven by a turbing at a rate of 10 cubic meters per second
lt ifre plant efficiency is Off,
-@Ji5e00 the power plantoutput'
4."i0,b001(\A,
9919Y!-ate
t{/v i.35,000-Kru D' 2s'000lflv

effciency al 92o/o' The effective


1 1. A hydroelectric station has a turbine efficiency ol !60/o and a gengratol
delivering a load of 40 MW for 6
head of water is 150 m. calculate ttie votunie of water usei when
hours.
x 1oam3 B. 4.158 x 10a m3 c. 82.54 x ldmB D. 94'48 x 10a m3
@z+.ta
in a year, .0.!to.urs.qer day'
12. An industry having a maximum demand of 1000 kw works for 320 days
the daily load factor'
-
Assuming rhat ndo*s at full r"p".ity a[ the time during working days,_calcttlate
33.33%
A. 56.2% 8.670/o c9 D' 29'5o/o

- REE SePt 2011


13. A power station has a peak demand of 80 run , and load factor of
0.60. lf the capacity factor is 50%
and utilization factor is AO4 find the daily energy^produced in MWHR'
A.960 @t,tsz c.2,4oo D' 2'304

REE-SePt 2015
A power plant has a peak demand of B0 r\n , and a connected load of 150 fuuu' lt
produces a total
14.
of the plant?
d;ot
€ "sll@'si.oC'2"
<)-" +OO,OOO nfWHn gnrylally, What is the rynual load factor
B. 30"44?o c- 60.88% D' 45'66%

REE-Apr.20{1
15. The po\A,er plant has a peak demand of 90llM/, capacity factor of 0.50, use factor of 0.80 and load
fador d 0.60. Find the plant installed capacity. ,-^
A. 115 MW B. 110 tr/lw Q)toe unru D. 105 M\A'

factor are 50%


16. A power plant has a maximum demand of 'l5lvIW. The annual load factor and capacity
aid 40"/o', respec{ively. Determine the reserved pqpacity oflhe plant.
'
A.735skW B. 5370 kw szso
Q) *w D. s075 kw

17. A 100 MW power station delivers 100 MW for 2 hrs, 50 lvtvv for 6 hrs and is shut down for the rest of
each day. lt is also shut down for maintenan@ for 45 days each year. Calculate the annual
load
factor.
8. s8.9% C"20.83o/o D.78.5o/o
@ra.s*
18. A power station has a load cycle as follows:
260 tVt\A/ for 6 hrs 20b Nn / for 8 hrs 160 IvlW for 4 hrs 100 MW for 6 hrs
lf the station is equipped with 4 sets of 75 ll\r1/ each, calculate the capacity factor-

@ei.rx 8.34.s% c.23-6% D' 76'506

19. The cunent loads of four circuits are as follows:


Amperes
Circuit no. 1 = 25 Circuit no. 3 = 18 Amperes
Amperes
Circuit no. 2 = 38 Circuit no.4 = 45 Amperes
lf the diversity factor is 1.'5. What is the minimugqmpa_city of the feeder conductor?
A. 126Am$res B. lSgAmperes gJ84Amperes D. lszAmperes

Porer System