You are on page 1of 1

PREDOMINANT NOTES

S1
PREVAILING WIND (SUMMER)
1. FOR KEY PLAN, NOTES, ABBREVIATIONS, REFERENCE DRAWINGS, WALL OPENING, MCT DETAILS, MTO &
HOLD REFER SHEET NO. 001 OF THIS DRAWING.
002

E
TRU TH
NOR 3° PLANT
2 NORTH
DRP001-OUF-GAL-940090-K-ECR-002

N
81°

MECCA

PREVAILING WIND
(WINTER)

1 2 3 4

16000
4550 5350 6100

AIR
STACK SANITARY MANHOLE

FROM 940-GSDO-0761(SMOKE DETECTOR DUCT)


AHU TO 940-GSDO-0771 (SMOKE DETECTOR ABOVE
5200

FALSE CEILING) REFER SHT-001


IFU-001
OUTDOOR
UNIT

ODU1
CONDENSATE DRAIN
A1
C OFFICE -
FD MALE PRAYER FEMALE FEMALE
FD
PRAYER TEAM
1200

1200
MALE SHOWER ROOM
1000 1000
SHOWER
LEADER /
REFER MATCH LINE A-A
ROOM
ELECTRICAL

PERMITTING
ROOM

S FC S S S FC
FC FC
RAMP UP 1000
1525
S FC
1500

1500
SLOPE 1:10 1200
5400

MALE LOCKERS IWO-13

1850
FEMALE
IWO-14 LOCKERS
IWO-08 IWO-15 IWO-29
IWO-12 MALE FEMALE IWO-07
MALE W.C.

FEMALE
TOP+98.850 ABLUTION ABLUTION TOP+98.850 W.C.
S S S S S
11000

FC FC FC FC FC AIR LOCK UP
1025

1025

1025

1025
FD 350 850 FD 1375 940BG15-FAS-FACP-01
FD FD
FIRE ALARM PANEL
B 1300 HRC 5050 4700 3300 S FC
EL. +95.300

1200
UP FFL (UNO)
IWO-06 TOP+98.850 665
S HRC
200

FC CORRIDOR S FC S FC
JANITOR 2
FD DWF IWO-03 FD
S
413

FC
BREAK PPE
5600

ROOM STORE GENERAL


700 IWO-32
990

OFFICE
RAMP UP 1650 4650 3000
SLOPE 1:10 S FC S FC S FC
TOP+98.850
1275 S S
1380

FC FC SLOPE
1900

IWO-05
1240

1240

1%
FD IWO-04 S
CLEAN FC

A AGENT
SHELTER SLOPE CABLE RAISE FROM EL. 95.100 TO REMOTE INDICATOR
SLOPE
1%

EL. 95.150
1% CABLE RAISE FROM EL+98.850 (940-GSDO-0791)
(FFL)
OUTDOOR UNIT TO EL+98.300 (940-GSDO-0721)

690
FFL +95.300
EL. +95.000 FFL +95.300 CL OF LADDER S FF SSL +94.550
HPP SSL +94.550
50MM CABLE TRAY
TELECOM

1380
CABLE DROP FROM EL. 98.300 (940-GSDO-0791) EL. 95.100 TELECOM EQUIPMENT ROOM
SLOPE 1:10

EQUIPMENT CABLE ENTRY TO EL. 95.100 FALSE FLOOR (940-GSDO-0721) 940BG15-GR1-P-501A


RAMP UP

ROOM BELOW GRADE


S FF CABLE RAISE FROM EL. 95.100 (940-GSDO-0722) TO EL.
CABLE RAISE FROM EL. 98.300 (940-GSDO-0722) TO EL. 98.200 (940-JBDG-832)THROUGH CABLE TRUNKING
98.200 (940-JBDG-832)THROUGH CABLE TRUNKING A CABLE DROP FROM EL. 98.300 (940-GSDO-0791)
TO EL. 95.100 FALSE FLOOR (940-GSDO-0721)

940BG-015
CABLE ROUTE LAYOUT- OPERATOR HOUSE TANKAGE (SLOP OIL/INTERMEDIATE) GROUND FLOOR PLAN
GROUND FLOOR PLAN (UNDER FALSE FLOOR)
(ABOVE FALSE CEILING)

S1 26/APR/19 ISSUED FOR CONSTRUCTION SJ MN SK


R1 16/OCT/19 ISSUED FOR CONSTRUCTION (WITH HOLD) SJ IJ SK

940BG15-GR1-P-501A
50W EL. 95.100
940-GSDO-0791-F
940-GSDO-0722-F
940-GSDOI-0721-F
940-GSDOI-0722-F
CNT-1100-1000-007
JI-2037/SO0267 PROJECT INTERNAL

CABLE ROUTE LAYOUT


OPERATOR HOUSE TANKAGE (SLOP OIL/INTERMEDIATE)
2m 0 2m 4m 6m 8m

SCALE 1:100 1:100 DRP001-OUF-GAL-940090-K-ECR-002 002 S1


SO0267-EK0D-ZZZ-940090-K-ECR-002-001
DRP001-OUF-GAL-940090-K-ECR-002-002-S1.dwg