You are on page 1of 1

falatghareh.

ir
falatghareh.ir
ARTICLE 8 ASME BPVC.V-2019

ARTICLE 8
EDDY CURRENT EXAMINATION

ð19Þ T-810 SCOPE (h) Mandatory Appendix VI, Eddy Current Detection
and Measurement of Depth of Surface Discontinuities in
When specified by the referencing Code Section, the
Nonferromagnetic Metals With Surface Probes, provides
eddy current examination method and techniques de-
the requirements for surface probe eddy current exami-
scribed in this Article shall be used.
nation for detection of surface connected discontinuities
(a) This Article describes the techniques to be used
and measuring their depth.
when performing eddy current examinations on
conductive-nonferromagnetic and coated ferromagnetic (i) Mandatory Appendix VII, Eddy Current Examina-
materials. tion of Ferromagnetic and Nonferromagnetic Conductive
(b) The requirements of Article 1, General Require- Metals to Determine If Flaws Are Surface Connected, pro-
ments, also apply when eddy current examination, in ac- vides the requirements for eddy current examination
cordance with Article 8, is required by a referencing Code with a surface probe to determine if flaws are surface con-
Section. nected in both ferromagnetic and nonferromagnetic
(c) Definitions of terms for eddy current examination metals.
appear in Article 1, Mandatory Appendix I, I-121.5, ET (j) Mandatory Appendix VIII, Alternative Technique
— Electromagnetic (Eddy Current). for Eddy Current Examination of Nonferromagnetic Heat
(d) Mandatory Appendix II, Eddy Current Examination Exchanger Tubing, Excluding Nuclear Steam Generator
of Nonferromagnetic Heat Exchanger Tubing, provides Tubing, provides the requirements for an alternative
the requirements for bobbin coil multifrequency and mul- technique for bobbin coil multifrequency and multipara-
tiparameter eddy current examination of installed non- meter eddy current examination of installed nonferro-
ferromagnetic heat exchanger tubing. magnetic heat exchanger tubing, excluding nuclear
(e) Mandatory Appendix III, Eddy Current Examination steam generator tubing.
on Coated Ferromagnetic Materials, provides eddy cur-
(k) Mandatory Appendix IX, Eddy Current Array Exam-
rent requirements for eddy current examination on
ination of Ferromagnetic and Nonferromagnetic Materials
coated ferromagnetic materials.
for the Detection of Surface-Breaking Flaws, provides the
(f) Mandatory Appendix IV, External Coil Eddy Current
requirements for eddy current array (ECA) surface probe
Examination of Tubular Products, provides the require-
ments for external coil eddy current examination of seam- examination of coated and noncoated ferromagnetic and
less copper, copper alloy, austenitic stainless steel, Ni- nonferromagnetic materials for the detection of
Cr-Fe alloy, and other nonferromagnetic tubular products. surface-breaking flaws.
(g) Mandatory Appendix V, Eddy Current Measurement (l) Mandatory Appendix X, Eddy Current Array Exam-
of Nonconductive-Nonferromagnetic Coating Thickness ination of Ferromagnetic and Nonferromagnetic Welds
on a Nonferromagnetic Metallic Material, provides the re- for the Detection of Surface-Breaking Flaws, provides
quirements for surface probe eddy current examination the requirements for ECA surface probe examination of
--`,``,``,,`,`,,````,`,``,,,`-`-`,,`,,`,`,,`---

for measuring nonconductive-nonferromagnetic coating coated and noncoated ferromagnetic and nonferromag-
thicknesses. netic welds for the detection of surface-breaking flaws.

246
Copyright ASME International (BPVC)
Provided by IHS under license with ASME Licensee=Khalda Petroleum/5986215001, User=Amer, Mohamed
No reproduction or networking permitted without license from IHS Not for Resale, 07/02/2019 13:29:23 MDT

You might also like