Professional Documents
Culture Documents
CONSULTANT
Quality Austria Central Asia Private Limited
(A Peacock Global Company)
52-B, Okhla Industrial Area, Phase-III New Delhi - 110 020
CLIENT
3.3 Tower
3.3.1 Visible health of tower Good/ Average/ Poor
3.3.2 Any rusted members (Write details of members)
Found / Not found
4.1.2 Antenna Loading Photo (Close up from all three Leg Faces) Photo No.2
4.2.8 Tower Painting ‐ Indicating Poor Quality Observed Not observed If observed, Take photograph
4.2.11 Shelter ‐ Leakages / Cracks / Other defects Observed Not observed If observed, Take photograph
4.2.13 D.G ‐ Cable Connectivity faults / Painting faults Observed Not observed If observed, Take photograph
4.2.15 Earthing Connectivity ‐ Rusting / Break Points Observed Not observed If observed, Take photograph
4.1 Photos ‐ Mandatory
Photo No : 1 Photo No : 2
Antenna Loading Photo (Close up from all three Leg
Description: Overall Site Photograph Description: Faces)
Photo No : 3 Photo No : 4
Description: Shelter ‐ Door Open / Close Description:
Description: LADDER
Photo No : Photo No :
Description: Tower Base Plate ( Close up) Description: Tower Base / Pedestal / Foundation Arrangement
5. AS BUILD DRAWING FOR SITE
DRAWINGS
SNO. Description Sheet No.
1 1. SITE LAYOUT 1 of 2
2 2. TOWER ELEVATION 2 of 2
52-B, OKHLA PHASE III,
OKHLA INDUSTRIAL AREA,
NEW DELHI 110020
TOWER LOAD
VALIDATION ACTIVITY
ID : SHS-01
NAME : SAMSHABAD
ADDRESS : MAHMUDABAD,
SITAPUR
CIRCLE : UPE
SITE LAYOUT
DRN. BY : ANSHUL
DGN. BY : KANCHAN
APP. BY : ARSHAD
DATE : 05-04-2019
SHEET : 1/2
REVISION : 0
52-B, OKHLA PHASE III,
OKHLA INDUSTRIAL AREA,
NEW DELHI 110020
TOWER LOAD
VALIDATION ACTIVITY
ID : SHS-01
NAME : SAMSHABAD
ADDRESS : MAHMUDABAD,
SITAPUR
CIRCLE : UPE
TOWER ELEVATION
DRN. BY : ANSHUL
DGN. BY : KANCHAN
APP. BY : ARSHAD
DATE : 05-04-2019
SHEET : 2/2
REVISION : 0
Project TLVA, BHARTI INFRATEL LTD.
CONTENTS :
SIZE/DIA OF BOTTOM LEG = NB 175 (H) (AS PER SITE SURVEY DATA)
FOUNDATION BOLT PER LEG = 12 no.s (AS PER SITE SURVEY DATA)
BASE PLATE SIZE = 400 X 400 X 25 mm (AS PER SITE SURVEY DATA)
FOUNDATION TYPE FRAMED LOAD BEARING N/A (AS PER SITE SURVEY DATA)
CRACKS OBSERVED IN FOUNDATION NOT VISIBLE VISIBLE (AS PER SITE SURVEY DATA)
BUILDING DETAILS
BUILDING TYPE FRAMED LOAD BEARING N/A (AS PER SITE SURVEY DATA)
AUDIT DETAIL
TOWER AUDITED BY = KHEMRAJ PANDEY & HEMANT
DESIGNATION = SITE ENGINEER
CONSULTANT'S NAME = QUALITY AUSTRIA CENTRAL ASIA PVT. LTD.
DESIGNED KANCHAN CHECKED ARSHAD APPROVED ARSHAD Antenna Loading Details Sheet
G.S.M./GRID Antenna Exposed Area Leg wise M/w Antenna Exposed Area Leg wise
L1 3.7997 m2 L1 4.947 m2
L2 4.0916 m2 L2 2.686 m2
L3 3.9803 m2 L3 3.392 m2
Wind Speed = 47 m/sec Wind Directionality Factor(Kd) = 0.9 (For towers) (Clause 7.2.1) ( As Per IS 875 Part-3 2015)
Probability factor (K1) = 1 Area Averaging Factor(Ka) = 1 (Clause 7.2.2)
Topography Factor (K3) = 1
Importance Factor (K4) = 1
Accessory Load = 0.499 sqm/m
Terrain Category = 2
Design Period = 50 Year
1 38.75 1.1419 172.8 155.5 0.410 0.171 2.82 4.77 0.45 1.63 292.4 194.0 1784.9
2 36.25 1.1356 170.9 153.8 0.410 0.171 2.82 4.74 0.45 1.63 289.2 191.9 570.6
3 33.75 1.1294 169.1 152.1 0.410 0.171 2.82 4.72 0.45 1.63 286.0 189.8 468.4
4 31.25 1.1231 167.2 150.5 0.506 0.191 2.74 4.69 0.45 1.61 316.2 187.7 466.7
5 28.5 1.1125 164.0 147.6 0.674 0.205 2.68 5.98 0.69 1.60 428.1 221.0 289.9
6 25.5 1.0975 159.6 143.7 0.638 0.167 2.83 5.90 0.69 1.63 420.5 215.1 0.0
7 22.5 1.0825 155.3 139.8 0.696 0.167 2.83 7.11 0.84 1.00 392.8 209.3 0.0
8 19.5 1.0680 151.2 136.1 0.756 0.152 2.89 7.01 0.84 0.96 406.7 203.7 0.0
9 15 1.0500 146.1 131.5 1.872 0.156 2.88 8.15 1.98 0.97 960.3 393.7 0.0
10 9 1.0000 132.5 119.3 2.106 0.138 2.95 7.91 2.02 0.91 960.9 357.1 0.0
11 3 1.0000 132.5 119.3 2.643 0.142 2.93 9.10 2.33 0.93 1181.1 357.1 46.6
G.S.M / R.R.U ANTENNA LOAD CALCULATION M/w CALCULATION TOTAL ANTENNA'S WIND LOAD
DESIGN FINAL DESIGN FINAL TOTAL WT TOTAL
SL. LENG WIDT REDUCTUTI Cf QT SHIELDIN LE UNIT SHIELD REF. TOTAL
HT l/b WIND WIND DIA HT AREA Cf QTY WIND WIND LEG G.S.M & WT.
NO. TH H ON FACTOR n Y G G WT ING HT SUM
PRESSURE FORCE PRESSURE FORCE R.R.U M/w
1 2.70 0.32 1 B 8.4 0.68 2 1 155.5 182.9 1 L1 1 1.8 424 0.5 B 2.54 1.2 1 155.5 474.85 1 L1 0.0 A 0.0 0.0 0.0
2 1.30 0.35 1.5 B 3.7 0.64 2 1 155.5 91.0 1 L1 2 0.9 109.3 5 E 0.64 1.2 1 153.8 117.42 1 L1 0.0 B 1310.0 474.9 1784.9
3 2.70 0.32 1.5 B 8.4 0.68 2 1 155.5 182.9 1 L1 3 0.9 109.3 5.5 F 0.64 1.2 1 152.1 116.13 1 L1 2.5 C 0.0 0.0 0.0
4 2.28 0.32 11 J 7.1 0.67 2 1 147.6 144.9 1 L1 4 1.2 193 9.5 H 1.13 1.2 1 150.5 204.17 1 L1 0.0 D 361.9 208.7 570.6
5 2.28 0.32 11 J 7.1 0.67 2 1 147.6 144.9 1 L1 5 1.2 193 4.5 D 1.13 1.2 1 153.8 208.74 1 L2 5.0 E 0.0 117.4 117.4
6 2.28 0.32 0.5 B 7.1 0.67 2 1 155.5 152.7 1 L2 6 0.9 109.3 6 F 0.64 1.2 1 152.1 116.13 1 L2 0.0 F 29.7 438.7 468.4
7 1.30 0.35 1 B 3.7 0.64 2 1 155.5 91.0 1 L2 7 0.6 48.3 7.5 G 0.28 1.2 1 152.1 51.61 1 L2 7.5 G 29.7 51.6 81.3
8 2.70 0.32 2 B 8.4 0.68 2 1 155.5 182.9 1 L2 8 0.9 109.3 9.5 H 0.64 1.2 1 150.5 114.85 1 L2 0.0 H 147.7 319.0 466.7
9 2.70 0.32 4.5 D 8.4 0.68 2 1 153.8 180.9 1 L2 9 1.2 193 5.5 F 1.13 1.2 1 152.1 206.45 1 L3 10.0 I 58.8 204.2 262.9
10 2.70 0.32 4.5 D 8.4 0.68 2 1 153.8 180.9 1 L2 10 1.2 193 10 I 1.13 1.2 1 150.5 204.17 1 L3 0.0 J 289.9 0.0 289.9
EXISTING ANTENNA'S
EXISTING ANTENNA'S
11 2.28 0.32 0.5 B 7.1 0.67 2 1 155.5 152.7 1 L3 11 1.2 193 13 K 1.13 1.2 1 147.6 200.33 1 L3 13.0 K 144.9 200.3 345.3
12 1.30 0.35 1 B 3.7 0.64 2 1 155.5 91.0 1 L3 0.0 L 0.0 0.0 0.0
13 2.70 0.32 1.5 B 8.4 0.68 2 1 155.5 182.9 1 L3 16.0 M 0.0 0.0 0.0
14 2.28 0.32 9 H 7.1 0.67 2 1 150.5 147.7 1 L3 0.0 N 0.0 0.0 0.0
15 2.28 0.32 13 K 7.1 0.67 2 1 147.6 144.9 1 L3 19.0 O 0.0 0.0 0.0
16 0.45 0.35 6 F 1.3 0.62 2 1 152.1 29.7 1 L1 0.0 P 0.0 0.0 0.0
17 0.45 0.35 39 V 1.3 0.62 2 1 119.3 23.3 1 L3 22.0 Q 0.0 0.0 0.0
18 0.45 0.35 10 I 1.3 0.62 2 1 150.5 29.4 1 L2 0.0 R 0.0 0.0 0.0
19 0.45 0.35 10 I 1.3 0.62 2 1 150.5 29.4 1 L2 28.0 S 0.0 0.0 0.0
20 0.45 0.35 7.5 G 1.3 0.62 2 1 152.1 29.7 1 L3 0.0 T 0.0 0.0 0.0
21 0.45 0.35 38 V 1.3 0.62 2 1 119.3 23.3 1 L3 34.0 U 0.0 0.0 0.0
0.0 V 46.6 0.0 46.6
40.0 W 0.0 0.0 0.0
MAIN LEG MEMBERS DESIGN CHECK
For Tubular Member as Per IS 800-2007
UNFACTORED CONNECTED EFFECTIVE PARTIAL PROPOSED MEMBER C/S RADIUS OF FOS (For Existing
MEMBER NO. L/rxx L/rvv K kL/r COMPRESSION DESIGN CAPACITY TENSILE DESIGN CAPACITY
FORCE (KG) LENGTH LENGTH LENGTH SECTION SIZE AREA GYRATION, r Loading)
PANEL
DIAGONAL IN IN NO. OF IN IN IN
NO. TYPE SIZE rx rv fcc λ φ fcd Pd α IN COMP.
MEMBERS COMP. TENSION BOLTS YIELDING RUPTURE TENSION
cm cm cm mm cm2 cm cm Kg/cm2 Kg/cm2 kg kg kg
P1 1001 TO 1006 615.6 607.0 320 160 160 ISA 50X50X6 5.68 1.51 0.96 107 167 1 167 720 1.88 2.68 505 2867 2 0.6 13154 11391 4.66 18.76
P2 1007 TO 1012 1508.6 1482.7 320 160 160 ISA 50X50X6 5.68 1.51 0.96 107 167 1 167 720 1.88 2.68 505 2867 2 0.6 13154 11391 1.91 7.68
P3 1013 TO 1018 2171.2 2129.8 320 160 160 ISA 50X50X6 5.68 1.51 0.96 107 167 1 167 720 1.88 2.68 505 2867 2 0.6 13154 11391 1.33 5.35
P4 1019 TO 1024 3047.6 2978.4 320 160 160 ISA 65X65X5 6.25 1.99 1.26 81 128 1 128 1226 1.44 1.84 774 4840 2 0.6 14474 12534 1.59 4.21
P5 1025 TO 1036 2506.4 2424.8 373 187 187 ISA 65X65X5 6.25 1.99 1.26 94 149 1 149 905 1.68 2.27 610 3812 2 0.6 14474 12534 1.53 5.17
P6 1037 TO 1048 2062.7 2073.9 400 200 200 ISA 65X65X5 6.25 1.99 1.26 101 159 1 159 795 1.79 2.49 548 3425 2 0.6 14474 12534 1.67 6.04
P7 1049 TO 1060 2156.5 2088.5 429 215 215 ISA 65X65X5 6.25 1.99 1.26 108 171 1 171 687 1.93 2.78 485 3030 2 0.6 14474 12534 1.41 6.00
P8 1061 TO 1072 1960.5 1954.4 461 230 230 ISA 65X65X5 6.25 1.99 1.26 116 183 1 183 600 2.06 3.08 432 2697 2 0.6 14474 12534 1.38 6.41
P9 1073 TO 1096 3597.8 3451.3 729 365 182 ISA 75X75X6 8.66 2.3 1.46 159 125 1 159 795 1.79 2.49 548 4746 2 0.6 20056 17367 1.32 5.03
P10 1097 TO 1120 2994.5 2906.5 781 391 195 ISA 75X75X5 7.27 2.31 1.46 170 134 1 170 695 1.91 2.75 490 3560 2 0.6 16837 14579 1.19 5.02
P11 1121 TO 1144 3097.1 2933.5 838 419 210 ISA 90X90X6 10.5 2.77 1.75 152 120 1 152 870 1.71 2.33 590 6198 2 0.6 24317 21057 2.01 7.18
CONNECTED EFFECTIVE PARTIAL PROPOSED MEMBER C/S RADIUS OF FOS (For Existing
MEMBER NO. MAX. FORCE (KG) L/rxx L/rvv K kL/r COMPRESSION DESIGN CAPACITY TENSILE DESIGN CAPACITY
LENGTH LENGTH LENGTH SECTION SIZE AREA GYRATION, r Loading)
PANEL
HORIZONTAL IN IN NO. OF IN IN IN
NO. TYPE SIZE rx rv fcc λ φ fcd Pd α IN COMP.
MEMBERS COMP. TENSION BOLTS YIELDING RUPTURE TENSION
cm cm cm mm cm2 cm cm Kg/cm2 Kg/cm2 kg kg kg
P1 2001 TO 2003 131.3 136.5 200 200 200 ISA 45X45X5 4.28 1.36 0.87 148 230 1 230 380 2.59 4.44 288 1232 1 0.6 9912 8583 9.39 62.88
P2 2004 TO 2006 2.9 24.5 200 200 200 ISA 45X45X5 4.28 1.36 0.87 148 230 1 230 380 2.59 4.44 288 1232 1 0.6 9912 8583 426 350.19
P3 2007 TO 2009 409.9 452.0 200 200 200 ISA 45X45X5 4.28 1.36 0.87 148 230 1 230 380 2.59 4.44 288 1232 1 0.6 9912 8583 3.01 18.99
P4 2010 TO 2012 1090.0 1159.5 200 200 200 ISA 45X45X5 4.28 1.36 0.87 148 230 1 230 380 2.59 4.44 288 1232 1 0.6 9912 8583 1.14 7.40
P5 2013 TO 2015 1062.3 1111.7 200 200 200 ISA 45X45X5 4.28 1.36 0.87 148 230 1 230 380 2.59 4.44 288 1232 1 0.6 9912 8583 1.17 7.72
UNFACTORED CONNECTED EFFECTIVE PARTIAL PROPOSED MEMBER C/S RADIUS OF FOS (For Existing
MEMBER NO. L/rxx L/rvv K kL/r COMPRESSION DESIGN CAPACITY TENSILE DESIGN CAPACITY
FORCE (KG) LENGTH LENGTH LENGTH SECTION SIZE AREA GYRATION, r Loading)
PANEL
DIAGONAL IN IN NO. OF IN IN IN
NO. TYPE SIZE rx rv fcc λ φ fcd Pd α IN COMP.
MEMBERS COMP. TENSION BOLTS YIELDING RUPTURE TENSION
cm cm cm mm cm2 cm cm Kg/cm2 Kg/cm2 kg kg kg
P1 1001 TO 1006 615.6 607.0 320 160 160 ISA 50X50X6 5.68 1.51 0.96 107 167 1 167 720 1.88 2.68 505 2867 2 0.6 13154 11391 4.66 18.76
P2 1007 TO 1012 1508.6 1482.7 320 160 160 ISA 50X50X6 5.68 1.51 0.96 107 167 1 167 720 1.88 2.68 505 2867 2 0.6 13154 11391 1.91 7.68
P3 1013 TO 1018 2171.2 2129.8 320 160 160 ISA 60x60x5 5.75 1.82 1.16 88 139 1 139 1040 1.57 2.06 682 3920 2 0.6 13316 11531 1.81 5.41
P4 1019 TO 1024 3047.6 2978.4 320 160 160 ISA 65X65X8 9.76 1.96 1.25 82 129 1 129 1207 1.45 1.86 765 7469 2 0.6 22603 19573 2.46 6.57
P5 1025 TO 1036 2506.4 2424.8 373 187 187 ISA 65X65X5 6.25 1.99 1.26 94 149 1 149 905 1.68 2.27 610 3812 2 0.6 14474 12534 1.53 5.17
P6 1037 TO 1048 2062.7 2073.9 400 200 200 ISA 65X65X5 6.25 1.99 1.26 101 159 1 159 795 1.79 2.49 548 3425 2 0.6 14474 12534 1.67 6.04
P7 1049 TO 1060 2156.5 2088.5 429 215 107 ISA 65X65X5 6.25 1.99 1.26 108 86 1 108 1723 1.22 1.49 987 6169 2 0.6 14474 12534 2.87 6.00
P8 1061 TO 1072 1960.5 1954.4 461 230 115 ISA 65X65X5 6.25 1.99 1.26 116 92 1 116 1493 1.31 1.62 895 5591 2 0.6 14474 12534 2.86 6.41
P9 1073 TO 1096 3597.8 3451.3 729 0 182 ISA 75X75X6 8.66 2.3 1.46 0 125 1 125 1286 1.41 1.79 802 6949 2 0.6 20056 17367 1.94 5.03
P10 1097 TO 1120 2994.5 2906.5 781 0 195 ISA 75X75X5 7.27 2.31 1.46 0 134 1 134 1119 1.51 1.96 722 5248 2 0.6 16837 14579 1.76 5.02
P11 1121 TO 1144 3097.1 2933.5 838 419 210 ISA 90X90X6 10.5 2.77 1.75 152 120 1 152 870 1.71 2.33 590 6198 2 0.6 24317 21057 2.01 7.18
CONNECTED EFFECTIVE PARTIAL PROPOSED MEMBER C/S RADIUS OF FOS (For Existing
MEMBER NO. MAX. FORCE (KG) L/rxx L/rvv K kL/r COMPRESSION DESIGN CAPACITY TENSILE DESIGN CAPACITY
LENGTH LENGTH LENGTH SECTION SIZE AREA GYRATION, r Loading)
PANEL
HORIZONTAL IN IN NO. OF IN IN IN
NO. TYPE SIZE rx rv fcc λ φ fcd Pd α IN COMP.
MEMBERS COMP. TENSION BOLTS YIELDING RUPTURE TENSION
cm cm cm cm2 cm cm 2 2 kg kg kg
mm Kg/cm Kg/cm
P1 2001 TO 2003 131.3 136.5 200 200 200 ISA 45X45X5 4.28 1.36 0.87 148 230 1 230 380 2.59 4.44 288 1232 1 0.6 9912 8583 9.39 62.88
P2 2004 TO 2006 2.9 24.5 200 200 200 ISA 45X45X5 4.28 1.36 0.87 148 230 1 230 380 2.59 4.44 288 1232 1 0.6 9912 8583 426 350.19
P3 2007 TO 2009 409.9 452.0 200 200 200 ISA 45X45X5 4.28 1.36 0.87 148 230 1 230 380 2.59 4.44 288 1232 1 0.6 9912 8583 3.01 18.99
P4 2010 TO 2012 1090.0 1159.5 200 200 200 ISA 50x50x5 4.79 1.52 0.97 132 207 1 207 469 2.33 3.74 348 1665 1 0.6 11093 9606 1.53 8.28
P5 2013 TO 2015 1062.3 1111.7 200 200 200 ISA 50x50x5 4.79 1.52 0.97 132 207 1 207 469 2.33 3.74 348 1665 1 0.6 11093 9606 1.57 8.64
(A) MAIN LEG d0 e p Asb Anb Kb For Bearing Shear Bearing Tensile
No. of Shear Min No. of No. of
Diameter Nominal Net tensile Capacity Capacity Capacity
Pann Factored Plate Min.edge Min.pitch (P/3d0)- kb Planes Capacity Bolts Bolts Status
Member No. Bolt Dia of bolt plain shank stress area e/3d0 fub/fu
el Force Thickness distance distance 0.25 intercepting Vdsb Vdpb Tdb of Bolt Required Provided
hole area (mm2) (mm2)
N mm mm mm mm mm mm2 mm2 N N N N
(A) MAIN LEG d0 e p Asb Anb Kb For Bearing Shear Bearing Tensile
No. of Shear Min No. of No. of
Diameter Nominal Net tensile Capacity Capacity Capacity
Pann Factored Plate Min.edge Min.pitch (P/3d0)- kb Planes Capacity Bolts Bolts Status
Member No. Bolt Dia of bolt plain shank stress area e/3d0 fub/fu
el Force Thickness distance distance 0.25 intercepting Vdsb Vdpb Tdb of Bolt Required Provided
hole area (mm2) (mm2)
N mm mm mm mm mm mm2 mm2 N N N N
Survey Data
Thickness of base plate = 25 mm
Dia of anchor bolts = 24 mm
Number anchor bolts 12 No's
Base Plate Dimension L or B = 400 mm
Concrete Padestal Dimension = 800 mm
Material properties
Characteristics strength of concrete fck = 20 N/mm²
fu = 410 N/mm²
fy = 250 N/mm²
ϒmo = 1.1
Design Loads
Maximum factored compression = 900 KN
Maximum factored tension = 850 KN
Maximum factored shear = 126 KN
Design data
Uplift Load = 850 KN
Shear load = 126 KN
Material
Grade of concrete fck = 20 N/mm²
The tower type is mentioned below on the basis of site survey conducted-
"After performing the detailed design check for the wind speed of 170 kmph on the tower, the tower is found unsafe on
existing antennas".
Comparasion of Foundation forces for the stability of foundation including existing loading-
The analysis has been carried out an independent structural analysis of the 40m high Triangular Hybrid tower for which the
configuration details, basic wind velocity and antenna loads for the designing are given above.
Results of the study indicate that the tower is structurally UNSAFE for the Existing antenna loading detials collected from the site.
Exclusion:-
1.) Structure confirmation against earthquake require detailed inputs on detailing and collection of these inputs are not
possible with available NDT method.Hence, analysis of foundation is excluded from the scope.
2.) Tower foundation material quality ,steel and durability check
3.) Any fabrication or repair work in tower ,foundation and building
Notes:-
1.) Joint survey required by the client, TLVA service provider and tower Strengthening service provider to validate
correction of tower strengthening drawing is compulsory required before Material fabrication.
2.) The strengthening vendor/agency has to ascertain the size of the members provided in the strengthening drawing before
making the fabrication drawing and if any discrepancy found must be inform to the design agency.qaca will not responsible
for any mismatch in the fabricated material at the time of execution
4. ±
PROJECT ID.
---------
SHS01
####
ETIC
NORTH
TRUE
H
NORT
MAGN
PANEL
PANEL MAIN LEG DIAGONAL HORZONTAL
HT.
P1
P2
P3
P4
P5
P6
P7
P8
TOWER PLAN
P9
P10
P11
P2
L-60x60x5 P3
L-65x65x8 L-50x50x5 P4
L-50x50x5 P5
P6
P7
P8
P9
P10
P11
VIEW 'B-B' REPLACE DIAGONAL MEMBER DP4 (ISA 65x65x8, 2959 LONG)
SIDE VIEW
VIEW 'A-A' HP4 & HP5
Ø17.5mm Hole
VIEW 'B-B' REPLACE HORIZONTAL MEMBER (HP4 & HP5 )ISA 50x50x5 OF 1871mm LENGTH
C1 / C2 PLT. 80x6 THK. (383mm LONG)
NB-125 CLAMP DETAIL
DETAIL-A
PANEL NO.-7
CLEAT (CL-1)
CLAMP DETAIL
DETAIL-A
PANEL NO.-8
DETAIL-B
PROPOSED IR1(ISA45X45X5)
PROPOSED HB1-(ISA45X45X5)
PROPOSED IR2(ISA45X45X5)
PROPOSED HB2-(ISA45X45X5)
PROPOSED IR3(ISA45X45X5)
DETAIL-C
SCHEMATIC DIAGRAM
UPPER FLANGE CONNECTION LOWER FLANGE CONNECTION MAIN LEG STRENGTHENING
SCHEMATIC DIAGRAM
MAIN LEG STRENGTHENING
STRIP DETAILS
STRIP DETAILS
SCHEMATIC DIAGRAM
TYPICAL DETAIL OF STRIP & BASE PLATE BETAIL-B
MAIN LEG STRENGTHENING IN BOTTOM
FLANGE PLATE CONNECTION WITH PIPE
TOWER LOAD VALIDATION ACTIVITY (3L-HYBRID)
BILL OF QUANTITY
TOWER LOAD VALIDATION ACTIVITY (3L-HYBRID)
BILL OF QUANTITY
TOWER LOAD VALIDATION ACTIVITY (3L-HYBRID)
BILL OF QUANTITY
TOWER LOAD VALIDATION ACTIVITY (3L-HYBRID)
BILL OF QUANTITY