Professional Documents
Culture Documents
GERENCIA DE OPERACIONES
CENTRO CONTROL OPERACIONAL
FREC. OP. VHF 130.150 FREC. AIRE/TIERRA 130.050 CCO 591-68968335 / 591-71440584
" CABIN
ESTACIÓN CBB 23-70-01 (3) D 28/07/21 READY INOP
" (O)
FECHA 15-04-2021
LIBERADOR S. LIMA
SERVICIOS AERONAVE
HYD REPORT: RIGHT LANDING GEAR LOCK LIGHT
0/0 NLG#1: PSI 120
Y/G INOPERATIVE
ACTION: WAS PERFORMED REPAIRED SOCKET GF
OIL 10 RIGHT REAR INDICATION IAW WM 32-60-07 FIG 1,
0 NLG#2: PSI 120
E#1 PAG 2 IN ANUNCIATOR TEST OK IAW AMM 31-51-00
IN A SATISFACTORY WAY
OIL 0 PPL#1: PSI 155 REPORT: "L NAV" Nº2 INOPERATIVE
E#2
ACTION: NAVIGATION DATABASE UPDATE
OIL 0 PPL#2: PSI 150 PROCEDURE WAS PERFORMED IAW AMM 34-61-
E#3
03/509 IN A SATISFACTORY WAY
OIL 0 PPL#3: PSI 150 REPORT: MAINTENANCE PANEL ENG#4 O/PRESS
E#4
ACTION: WAS ADJUSTED ISOLATION/PRESURE
REDUCING VALVE IAW AMM 36-11-00/501 AND TEST
IAW AMM 72-00-00/501 IN A SATISFACTORY WAY
E-MAINT-042-21