Page 1 of 10
100, 200
PARTS ON/OFF
REMOVED INSTALLED
Description
Qty P/N S/N Position Reason Qty P/N S/N
No Parts Required
TOOLS
NAME P/N S/N CHECKED OUT TO
No Tools Required
MEASUREMENTS
PARAMETER VALUE SIGNED_BY
No Measurement Recorded
ACTIONS
DISCREPANCY FOUND
No Additional Faults Found
ECRA 0550-0025C
GENERAL INSTRUCTIONS:
1. If any steps on this task card cannot be accomplished due to an existing placard, note this
information in step 3, and proceed to next step.
Page 2 of 10
1) Flight Compartment
a) Annunciator Lights
(i) Perform light test using master DIM and TEST switch and verify proper
annunciator light operation.
(iv) Verify white IRS ALIGN lights illuminate after 10 seconds indicating start
of alignment
(v) Verify that after 10 minutes of successful alignment, the IRS automatically
enters NAV mode.
(vi) Push the Auto flight status annunciator test switch to the No. 1 position, all
3 annunciator lights illuminate amber. Push the test switch to the No. 2
position, the A/P and A/T annunciators come on red. The FMC annunciator
comes on amber.
b) Flight Recorder
(i) Move flight recorder test switch to TEST position. Verify OFF light extinguishes.
Return switch to NORMAL.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 3 - Pending
(i) Press MACH AIRSPEED WARNING TEST and verify clacker sounds.
(ii) Press stall warning TEST buttons until control column shaker activation occurs.
NOTE: With HYD power off, leading edge flaps may droop, causing asymmetry
signal resulting in failure of stall warning system test. Should this occur,
pressurize B system to fully retract flaps. The stall-warning test requires
that the A/C transfer busses be powered 4 minutes prior to testing.
e) EECs ON
TASK CARD Date Printed: 19-JAN-2022 20:36 UTC
Page 3 of 10
. f) Passenger Oxygen
(i) Verify annunciator light out, switch capped and safe tied.
g) GPS Light
h) PSEU Light
(i) Verify all switches are in a normal (Off or Detent) position. In most cases
push button switches are selected if they are illuminated. Prior to turning
any system off or deselecting a system verify that maintenance is not using
the active system.
(ii) STBY HYD, LOW QTY, LOW PRESS and STBY RUD ON lights out.
(iv) Verify FEEL DIFF PRESS, SPEED TRIM FAIL, MACH TRIM FAIL and AUTO SLAT
FAIL annunciators not illuminated.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 6 - Pending
. k) Fuel System
(i) Verify ENG VALVE CLOSED lights are on dim, spar valve closed lights on
dim, and fuel filter bypass lights are extinguished.
(ii) Verify cross feed selector is CLOSED and the VALVE OPEN light is
extinguished.
CAUTION: FOR GROUND OPERATION, CENTER FUEL TANK PUMP SWITCHES MUST
NOT BE POSITIONED TO "ON" UNLESS THE CENTER TANK FUEL
QUANTITY EXCEEDS 1,000 POUNDS, EXCEPT WHEN DEFUELING
OR TRANSFERRING FUEL.
TASK CARD Date Printed: 19-JAN-2022 20:36 UTC
Page 4 of 10
(iii) Verify pumps are ON for any tanks that contain fuel. Verify PUMP LOW
PRESS lights are extinguished.
(iv) Position fuel pump switches OFF. If the APU is to remain running, provide
positive fuel pressure by leaving one boost pump (No. 1 tank/ AFT) ON.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 7 - Pending
m) Electrical Systems
n) Equipment Cooling
o) Window Heat
(i) Turn 4 window heat switches ON. Observe green lights on.
. p) Probe Heat
(i) Turn A and B switches to ON. Verify all probe heat lights extinguish.
Page 5 of 10
. r) Hydraulics
(ii) Verify electric pump LOW PRESS lights extinguish. Brake pressure for system
A and B should be 2800 PSI minimum.
(iv) Ensure hydraulic quantity gages read between 84 and 100 percent (Flaps up
and engines off).
(v) Verify Brake Accumulator Pressure is greater than or equal to 2800 PSI.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 10 - Pending
. s) Voice Recorder
(ii) Verify needle moves to/or remains in green band entire time button is depressed. F
737-800NG fleet verify the test light comes on and stays on entire time button is
depressed.
t) Air Conditioning
(i) Verify trim air switch is on. Verify zone temp lights are extinguished (B737-800 only).
Turn trim air switch back off.
(iv) Verify both wing to body overheat lights, the master caution lights, and air
conditioning system annunciator lights are illuminated.
Page 6 of 10
(viii) Verify ram air door full open lights are ON.
. u) Flight Instruments
NOTE: May have to turn all the fuel boost pumps to the off position to
extinguish the config indication.
(ii) Check aircraft log book in block 46 and verify that the last known fuel quantity
matches fuel on board. If the aircraft was fueled or had an engine run during
the RON, verify the fuel added or used matches the fuel on board and record
the quantity in the required block of the log book.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 12 - Pending
. w) Engine Instruments
(i) Check N1 and N2 zero. Check pointers for EGT, FF, oil temperature and
oil pressure displays and also verify digital displays are present. They
will not be displayed until start switch is moved to GRD.
x) Anti-Skid
(i) Verify Autobrake DISARM light illuminates for 1 to 2 seconds and then
extinguishes. Return RTO switch to off.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 13 - Pending
Page 7 of 10
NOTE: The fuel spill warning DOES apply to the weather radar
test mode.
(i) Select any mode except TEST on the WXR control panel.
(iii) Select TEST on the WXR control panel and observe the results.
(v) Select mode selector (WXR switch) off at the end of the test.
(ii) Verify the INOP light, the PULL UP lights and the BELOW GLIDE
SLOPE lights illuminate and the aural warning sounds for one cycle.
(i) Verify speed brake lever is full forward and the speed brake ARM
light is extinguished.
(i) Advance throttles full travel and back. Verify throttles move freely
and take off warning horn is operating.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 15 - Pending
(i) Open the "OVHT WW WING BODY" circuit breaker on the F/O electrical
system panel P6-2.
TASK CARD Date Printed: 19-JAN-2022 20:36 UTC
Page 8 of 10
(vi) Verify bell sounds and that master fire warning, master caution lights
and OVHT annunciators are illuminated.
(vii) Close the "OVHT WW WING BODY" circuit breaker on the F/O electrical
system panel P6-2.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 16 - Pending
(ii) Verify extinguisher TEST lights (3 green) illuminate. Release the TEST switch
and verify all lights extinguish.
(iv) Verify the extinguisher TEST lights (3 green) illuminate. Release the TEST switch
and verify all lights extinguish.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 17 - Pending
(iii) Verify fire warning bell sounds and Master FIRE WARNING lights illuminate.
(v) Verify MASTER FIRE WARNING lights and fire warning bell cancel.
(vi) Verify CARGO FIRE (FWD & AFT) warning lights are illuminated.
Page 9 of 10
. gg) Transponder
NOTE: The Transponder should be in the STBY mode with the ADIRU aligned.
(i) Put the transponder select switch on the TCAS/ATC control panel to the
No. 1 position.
- Press and release the TEST switch on the mode select switch located
on the ATC control panel.
- The word TRAFFIC shows on the right side of the inboard displays.
- Make sure the outboard displays show the DO NOT CLIMB and DO
NOT DESCEND resolution advisory.
(ii) Do the test again (step (i)) with the transponder select switch on the control panel set to the No. 2 position.
. hh) Perform PA/INPH check from cockpit. Verify system operation is normal.
ii) If equipped, verify 120V, power is functioning for flight crew i-Pad Charger.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending
STEP 20 - Pending
. 2) Cabin
Page 10 of 10
a) Record the Log page numbers and description in the comments section, as applicable.
NOTE: Write down the answer for this steps on the comments section below.
SKILL SKILL STATUS WORK PERFORMED CERTIFICATION
MECH Pending