You are on page 1of 16

OPERATING LIMITS

Flow rates up to: 68 m3/h*


SCX-DCX - SXM-DXM
Heads up to: 19 m
Max. service pressure:
Temperature range:
10 bar
- 20° to + 130°C
SINGLE AND TWIN-HEAD CIRCULATORS
Max. ambient temperature:
ND of ports:
+ 50°C
32 to 80
Commercial heating & air conditioning
*136 m3/h: with both heads operating in parallel 2 pole - 50 Hz

19 APPLICATIONS
• Commercial central heating in housing, l • Primary loop, exchanger or heater, in
office buildings, greenhouses, swimming secondary hot water system.
pools, farms, etc.
H l• Air conditioning.
m
1 x SC X /DCX 2 x DCX/DXM l• Boiler recycling. All new or renovated installations.
1 x SXM/DXM
(in(inparallel)
parallel)

0 68 Qm3/h 136

• SCX (three-phase)

• DCX (three-phase)

• SXM (single-phase)

• DXM (single-phase)

N.T. No 122-1/ENG. - Ed.5/05-05


SCX-DCX - SXM-DXM

ADVANTAGES THE 2 POLE CIRCULATOR LINES


• Versatile circulators designed for use
in heating, air conditioning, and
secondary hot water circuits.
• Dual-voltage motors, 230-400 V.
• Built-in thermal overload protection
of motor.
• Redesigned casing for better
performance and even quieter
operation.
• SCX • SXM
• New impeller profile for optimum
efficiency.
• Lower energy consumption.
• Automatic venting of rotor chamber.
• DCX • DXM

DCX-DXM
• Standby pump available at all times.
• Possibility of operating the two pumps SCX - DCX SXM - DXM
in parallel, for lower purchase and Single and twin-head circulators Single and twin-head circulators
operating costs. • Threaded G2 and ND 40 to 80. • Threaded G2 and ND 40 to 80.
• Three-phase, dual voltage 230-400 V • Single-phase 230 V, winding motors with
motors. built-in capacitor.
• Voltages according to European standards. • Voltages according to European standards.
DESIGN • Three-speed motors by plug-in manual • Two-speed motors by plug-in manual
selector switch. selector switch.
• Pump • Built-in thermal overload protection. • Built-in thermal overload protection.
Flanged casing, in-line ports. • 13 single head models. • 9 single head models.
Bosses on rear for wall mounting. • 12 twin-head models. • 8 twin-head models.
Flanges fitted with pressure gauge ports.
New impeller profile. MIN. SUCTION PRESSURE (m w.g.) ACCORDING TO OPERATING TEMPERATURE
* threaded ports on model SCX 32-80. 3-phase 1-phase
MODEL SCX DCX SXM DXM 70°C 90°C 110°C 130°
Twin-head models (DCX-DXM) 32-80 ● – ● –
Twin pumps in a single casing. 8 12 19 32
50-90 ● ● ● ●
Hydraulic separation by double flap valve on 40-40 ● ● ● ●
● ● ● ●
5 09 16 29
discharge end. 65-50
40-80 ● ● ● ● 9 13 20 33
• Motors 50-25 ● ● ● ●
3 07 14 27
65-25 ● ● ● ●
2 pole, voltages according to European
50-50 ● ● ● ●
standards. ● ● ● ●
7 11 18 31
80-25
Wet rotor, self-lubricating sleeve bearings. 65-90 ● ● – – 12 16 23 36
– THREE-PHASE: dual voltage, 3 speeds by 80-50 ● ● – – 10 14 21 34
plug-in selector switch coupled to voltage 1801-2801 SX DX – –
12 16 23 36
(except SX 1801-1802, DX 2801-2802, with two-speed 1802-2802 SX DX – –
motors) NB: At high altitudes, add 0.60 m for every 500 m. (10.2 m w.g. = 1 bar)
– SINGLE-PHASE: 2 speeds by plug-in
selector switch, built-in capacitor. STANDARD CONSTRUCTION IDENTIFICATION
Speeds : see tables SCX 65-25
Windings 3-phase : 230-400V Main parts Material DCX 65-25
1-phase : 230V Pump casing Cast iron SCX: single pump, 3-phase
Frequency : 50 Hz Impeller Composite material DCX: twin pump, 3-phase
Protection index : IP 42 Shaft Stainless steel
Insulating category : F (155°C) ND of ports (mm)
Air gap sleeve Stainless steel
EC conformity Total pressure head (dm) nominal flow
EMC conformity - emission : EN 61000-6-3 Sleeve bearings Graphite
SXM: single pump, 1-phase
- immunity : EN 61000-6-2 Casing gasket Ethylene-Propylene DXM: twin pump, 1-phase

2
SCX-DCX - SXM-DXM

COMPETITIVE CHANGES

A B

THREE-PHASE, 2 P0LE MOTOR* THREE-PHASE MOTOR Examples:


• Dual-voltage, 3-phase 230-400 V TERMINAL BOX
A: speed 3 - Voltage 400 V
• With plug-in speed selector coupled to • Electrical connections easy to make, on
operating voltage (see opposite). very accessible terminal blocks. B: speed 2 - Voltage 230 V
• Built-in thermal overload probe protects
winding at all speeds by external relay. • Speed selected by plug-in manual selector The speed and operating voltage are
switch coupled to the operating voltage. displayed on the back of the terminal box.
• New, more attractive terminal box.
• Electrical connections via stuffing box,
input on right or left side.
• Display of rotation direction of motor,
speed selected, and operating voltage.
• New data plate with information about all
electrical values of the installed circulator.
• Very quiet motors.
For 4-poles motors C1000N and C2000N ranges see the
specific data sheets.

ROTOR-SHAFT
• The perforated shaft ensures a circulation
of water that allows automatic venting and
SINGLE-PHASE, 2 P0LE MOTOR lubrication.
• 230 V winding. • Permanent venting of the rotor chamber,
• Built-in capacitor. eliminating manual air bleed when starting.
• Two-speed plug-in manual selector switch. • Continuous lubrication of the rear sleeve
bearing.
• Connections to terminal blocks easy to
reach, cables enter on right or left side. • No more seizing of shaft.
• Built-in thermal overload probe protects
winding at all speeds by external relay.
IMPELLER
• New profile for high efficiency, lower energy
consumption and noise reduction.

3
SCX-DCX - SXM-DXM

GENERAL SELECTION GRAPHS AT MAXIMUM SPEED


Imp. gpm 40 60 80 100 120 140 160 180 200 220 240
SCX - Single Circulator Hm Hft
SCXSCX
2 POLE - 3-PHASE 18 2 POLE - 50 Hz 60

50 Hz
16
50
14

12 18 40
02
65-
10 90
180
1 30
40
8 -8
0 65-
50
6 20
40 80-
-4 65- 50
0 50
25
32-8

-9
4 50 0
-5
0 10
0

50- 80-
2
25 25

0
Qm3/h 5 10 15 20 25 30 35 40 45 50 55 60 65 70
Ql/min 100 200 300 400 500 600 700 800 900 1000 1100
Ql/s 3 5 7 9 11 13 15 17 19

Imp. gpm 20 40 60 80 100 120 140 160 180 200


SXM - Single Circulator Hm Hft
SXM
2 POLE- 1-PHASE SXM
2 POLE - 50 Hz
40
12
50 Hz

10
30

8
40
-8
0

65
6 -50 20

65-
40

25
32-80

4
50
-4
0

-9

50 80-2
0

10
50-2 -5 5
5 0
2

0
Qm3/h 5 10 15 20 25 30 35 40 45 50 55
Ql/min 100 200 300 400 500 600 700 800 900
Ql/s 1 3 5 7 9 11 13 15

MOUNTING
POSITION

(B): Do not use with


chilled water. (B)

4
SCX-DCX - SXM-DXM

GENERAL SELECTION GRAPHS AT MAXIMUM SPEED


Imp. gpm 40 60 80 100 120 140 160 180 200 220 240
DCX - Twin Circulator Hm Hft

DCXDCX
2 POLE - 3-PHASE 18 60
2 POLE - 50 Hz
50 Hz
16
50
14

12 40
28
02
10 65-
90
28 30
01
8 40
-8
0
65-
6 40 50 20
-40
80-
65- 50
4 25 50
-9
50 0 10
-5 80-2
2 0 5
50-
25
0 3
1 Qm /h 5 10 15 20 25 30 35 40 45 50 55 60 65 70

2 Qm3/h 10 20 30 40 50 60 70 80 90 100 110 120 130 140


2 pumps in operation

Imp. gpm 20 40 60 80 100 120 140 160 180 200


DXM - Twin Circulator Hm Hft

2 POLE - 1-PHASE DXM


12 2 POLE - 50 Hz 40
50 Hz

10

30

8
40
-8
0

65-
6 40 50 20
-4
0
65-
25
50

4
-9

80-2
0

50 5 10
-5
0
2
50-
25

0
1 Qm 3 /h 5 10 15 20 25 30 35 40 45 50 55

2 Qm 3 /h 10 20 30 40 50 60 70 80 90 100 110
2 pumps in operation

MOUNTING
POSITION
(A): possible mounting, but
needs periodical changeover
to avoid trapped air at the
high point, or connection of
a bleed to the port provided
for it (Ø 1/8").
(B): Do not use with chilled (A) (A) (B)
water.

5
SCX-DCX - SXM-DXM

SCX - SINGLE CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz


Imp. gpm 5 10 15 20 25 30 Imp. gpm 20 30 40 50 60 70 80
Hm Hft Hm Hft
10 SCX 32-80 7
SCX 50-50
9 ND 32-50Hz 30 ND 50-50Hz
6 3 20
8 25
7 3 2
5
6 20 1 15
2 4
5
1 15 10
4 3
3 10
2
2 5
5 1
1
0 3
0 3
Qm /h 1 2 3 4 5 6 7 8 9 Qm /h 2 4 6 8 10 12 14 16 18 20 22 24
Ql/min 20 40 60 80 100 120 140 Ql/min 50 100 150 200 250 300 350 400
Ql/s 0,5 1 1,5 2 2,5 Ql/s 1 2 3 4 5 6

Imp. gpm 10 20 30 40 50 60 Imp. gpm 20 40 60 80 100


Hm Hft Hm Hft
SCX 40-40 20
11 SCX 50-90 35
6
ND 40-50Hz 10 ND 50-50Hz
3 9 30
5 3
15 8
25
4 7
2 20
2 6
3 10
5 1
15
1 4
2
3 10
5
1 2
5
1
0 3
0
Qm /h 2 4 6 8 10 12 14 16 18 Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Ql/min 50 100 150 200 250 300 Ql/min 50 100 150 200 250 300 350 400 450 500
Ql/s 1 2 3 4 5 Ql/s 1 2 3 4 5 6 7 8

Imp. gpm 20 30 40 50 60 70 Imp. gpm 20 30 40 50 60 70 80 90 100


Hm Hft Hm Hft
10 SCX 40-80 SCX 65-25
30 7
9 ND 40-50Hz ND 65 -50Hz
6 20
8
25 3
7 5
3 20 15
6 2
2 4
5
1 15 1 10
4 3
3 10
2
2 5
5 1
1
0 3 0 3
Qm /h 2 4 6 8 10 12 14 16 18 20 Qm /h 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Ql/min 50 100 150 200 250 300 Ql/min 50 100 150 200 250 300 350 400 450 500
Ql/s 1 2 3 4 5 Ql/s 1 2 3 4 5 6 7 8

Imp. gpm 20 30 40 50 60 70 80 90 100 Imp. gpm 20 40 60 80 100 120


Hm Hft Hm Hft

3.5 SCX 50-25 12 9 SCX 65-50 30


ND 50-50Hz 8 ND 65-50Hz
3 3 10 3 25
7
2.5 8
2 20
6
2 5 1
2
6 15
1 4
1.5
4 3 10
1
2
0.5 2 5
1
0 0
Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28 Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36
Ql/min 50 100 150 200 250 300 350 400 450 Ql/min 100 200 300 400 500 600
Ql/s 1 2 3 4 5 6 7 Ql/s 1 2 3 4 5 6 7 8 9 10

6
SCX-DCX - SXM-DXM

SCX - SINGLE CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz


Imp. gpm 40 60 80 100 120 140 160 Imp. gpm 40 60 80 100 120 140 160 180 200
Hm Hft Hm Hft
13 14 SX 1801
SCX 65-90
12 40
ND 65-50Hz 12
2 ND 80-50Hz 40
11
3
10
9 30 10
2 1 30
8
7 8
1
6 20 20
6
5
4
4
3 10 10
2 2
1
0 3
0
Qm /h 5 10 15 20 25 30 35 40 45 Qm3/h 5 10 15 20 25 30 35 40 45 50 55
Ql/min 100 200 300 400 500 600 700 Ql/min 200 300 400 500 600 700 800 900
Ql/s 2 4 6 8 10 12 Ql/s 2 4 6 8 10 12 14

Imp. gpm 40 60 80 100 120 140 160 180 200 Imp. gpm 40 60 80 100 120 140 160 180 200
Hm Hft Hm Hft
7 SCX 80-25 18 SX 1802 60
ND 80-50Hz 16 ND 80-50Hz
6 20 2 50
3
14
5 2 40
12
15 1
4 1 10
30
3 10 8
6 20
2
5 4
1 10
2
0 3 0
Qm /h 5 10 15 20 25 30 35 40 45 50 55 Qm3/h 10 15 20 25 30 35 40 45 50 55 60
Ql/min 100 200 300 400 500 600 700 800 900 Ql/min 200 300 400 500 600 700 800 900 1000
Ql/s 2 4 6 8 10 12 14 Ql/s 2 4 6 8 10 12 14 16

Imp. gpm 50 100 150 200 250


Hm Hft
11 SCX 80-50 35
10 ND 80-50Hz
9 30
8 3 25
7
2
6 20
5 1
15
4
3 10
2
5
1
0
Qm3/h 10 15 20 25 30 35 40 45 50 55 60 65 70
Ql/min 200 400 600 800 1000
Ql/s 3 6 9 12 15 18

7
SCX-DCX - SXM-DXM

DCX - TWIN CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz


Imp. gpm 20 30 40 50 60 70 80 90 100 Imp. gpm 40 60 80 100 120 140 160
Hm Hft Hm Hft
(P1+ P DCX 40-40 11 DCX 50-90
6 (P1 2) 20 35
/P ND 40-50 Hz 10 (P1 (P1+ ND 50-50Hz
2) /P2 P2) 30
9 )
5 3 3
15 8
3 25
4 2
7 3
6
2 20
3 1 2
10 5 1 2
15
4
2 1 10
1 3
5
2
1 5
1
0 0
Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28 Qm3/h 8 12 16 20 24 28 32 36 40 44
Ql/min 50 100 150 200 250 300 350 400 450 Ql/min 100 200 300 400 500 600 700
Ql/s 1 2 3 4 5 6 7 Ql/s 2 4 6 8 10 12

Imp. gpm 20 40 60 80 100 Imp. gpm 40 60 80 100 120 140 160


Hm Hft Hm Hft
10 7
DCX 40-80 (P1+ P DCX 65-25
(P1 (P1+ 2)
9 /P2 P2) ND 40-50Hz 30 6 (P1 ND 65-50Hz 20
) /P2
8 3 3 ) 3
25
7 5 3
15
6 2 2 20
4 2
2
5
1 15 3 1 10
4 1 1
3 10 2
2 5
5 1
1
0 0
Qm3/h 4 8 12 16 20 24 28 32 Qm3/h 8 12 16 20 24 28 32 36 40 44
Ql/min 100 200 300 400 500 Ql/min 100 200 300 400 500 600 700
Ql/s 2 3 4 5 6 7 8 Ql/s 2 4 6 8 10 12

Imp. gpm 40 60 80 100 120 140 160 Imp. gpm 40 60 80 100 120 140 160 180
Hm Hft Hm Hft
DCX 50-25 9 (P1+ P2 DCX 65-50
3 (P1 (P1+ 10 )
/P P2) ND 50-50Hz (P1/ ND 65-50Hz
2) 8 P2)
25
2.5 3 3
3 8 7
3 2 20
2 6 2
2 6
5
1.5 2 1 15
1 4 1
4
1 3 10
1
2
2
0.5 5
1
0 0
Qm3/h 8 12 16 20 24 28 32 36 40 44 Qm /h
3
10 15 20 25 30 35 40 45 50
Ql/min 100 200 300 400 500 600 700 Ql/min 200 300 400 500 600 700 800
Ql/s 2 4 6 8 10 12 Ql/s 2 4 6 8 10 12

Imp. gpm 20 40 60 80 100 120 Imp. gpm 40 60 80 100 120 140 160 180 200
Hm Hft Hm Hft
DCX 50-50 (P1+ P DCX 65-90
7 (P1+ P (P1/ 2) 40
(P1 2) 12 P2)
/P2 ND 50-50Hz 3 ND 65 -50Hz
6 ) 20 3
3 10
3
2 2 30
5 2
2 15 8
4 1 1 1
1 6 20
3 10
4
2 10
5
1 2

0 0
Qm3/h 4 8 12 16 20 24 28 32 36 Qm3/h 10 15 20 25 30 35 40 45 50 55 60
Ql/min 100 200 300 400 500 600 Ql/min 200 300 400 500 600 700 800 900 1000
Ql/s 1 2 3 4 5 6 7 8 9 10 Ql/s 2 4 6 8 10 12 14 16

8
SCX-DCX - SXM-DXM

DCX - TWIN CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz


Imp. gpm 50 100 150 200 250 Imp. gpm 100 150 200 250 300 400
Hm Hft Hm Hft
7 DCX 80-25 DX 2801
(P1 (P1+ 14 (P1 (P1+
/P2 P2) ND 80-50Hz 20 /P P2) ND 80-50Hz
6 ) 2)
3 3 12 40
5 2 2
10
2 2 15 30
4 8 1 1
1 1
3 10 6 20

2 4
5 10
1 2

0 0
Qm3/h 10 20 30 40 50 60 70 80 Qm3/h 10 20 30 40 50 60 70 80 90 100
Ql/min 200 400 600 800 1000 1200 Ql/min 200 400 600 800 1000 1200 1400 1600
Ql/s 3 6 9 12 15 18 21 Ql/s 5 10 15 20 25

Imp. gpm 50 100 150 200 250 Imp. gpm 100 150 200 250 300 350 400
Hm Hft Hm Hft
11 DCX 80-50 (P1 (P1+ DX 2802 60
(P1+ P 18
10 (P1 2) ND 80-50Hz /P P2)
/P2 16 2) ND 80-50Hz
9 ) 3 30
3 2 50
8
14 2
7 2 12 40
2 1
6 20 10 1
1 30
5 1 8
4
6 20
3 10
4
2 10
1 2
0 0
Qm3/h 10 20 30 40 50 60 70 80 Qm3/h 20 30 40 50 60 70 80 90 100 110 120
Ql/min 200 400 600 800 1000 1200 Ql/min 400 600 800 1000 1200 1400 1600 1800 2000
Ql/s 5 10 15 20 Ql/s 5 10 15 20 25 30

NB: The hydraulic curves above and on the previous page give the hydraulic characteristics for one head in operation
(P1 or P2) and for both heads in parallel (P1 + P2).

ALTERNATING OPERATION PARALLEL OPERATION

P1 P2 P1 + P2

1 2 1 2 1 2

PUMP 1 OR PUMP 2 IN OPERATION Parallel operation of both heads for installation needs during the
the flowrate required, allows heating season.
ONE HEAD ON STANDBY ENSURES OPERATING RELIABILITY substantially lower purchase and The maximum hydraulic
WITH NO STOPPAGE OF THE INSTALLATION operating costs. performance needed is delivered by
Operation of the pumps programmed parallel operation of both heads.
and switched over by control box. A single head in operation provides A control box is used for
about 85% of the capacity the programming.

9
SCX-DCX - SXM-DXM

SXM - SINGLE CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz


Imp. gpm 5 10 15 20 25 30 Imp. gpm 20 30 40 50 60 70 80 90 100
Hm Hft Hm Hft
10 SXM 32-80 SXM 50-25 12
3.5
9 ND 32-50Hz 30 ND 50-50Hz
10
8
3 2
25
7 2 2.5 8
6 20
2
5 6
1 15
1.5
4 1
4
3 10
1
2 2
5 0.5
1
0 0
Qm3/h 1 2 3 4 5 6 7 8 9 Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28
Ql/min 20 40 60 80 100 120 140 Ql/min 50 100 150 200 250 300 350 400 450
Ql/s 0,5 1 1,5 2 2,5 Ql/s 1 2 3 4 5 6 7

Imp. gpm 10 20 30 40 50 60 Imp. gpm 20 30 40 50 60 70 80


Hm Hft Hm Hft
SXM 40-40 20 7 SXM 50-50
6
ND 40-50Hz ND 50-50Hz
6 20
5 2
2 15 5
4 15
4
3 10 1
3 10

2
1 2
5
5
1 1

0 0
Qm3/h 2 4 6 8 10 12 14 16 18 Qm3/h 4 6 8 10 12 14 16 18 20 22 24
Ql/min 50 100 150 200 250 300 Ql/min 50 100 150 200 250 300 350 400
Ql/s 1 2 3 4 5 Ql/s 1 2 3 4 5 6

Imp. gpm 20 30 40 50 60 70 Imp. gpm 20 40 60 80 100


Hm Hft Hm Hft
10 SXM 40-80 11 SXM 50-90 35
ND 40-50Hz 30 10 ND 50-50Hz
9
9 2 30
8
2 25 8
7 25
7
6 20
6 20
5 5
15 1 15
4 1 4
3 10 3 10
2 2
5 5
1 1
0 0
Qm3/h 2 4 6 8 10 12 14 16 18 20 Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28 30

Ql/min 50 100 150 200 250 300 Ql/min 50 100 150 200 250 300 350 400 450 500
Ql/s 1 2 3 4 5 Ql/s 1 2 3 4 5 6 7 8

10
SCX-DCX - SXM-DXM

SXM - SINGLE CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz DXM - TWIN CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz
Imp. gpm 20 30 40 50 60 70 80 90 100 Imp. gpm 10 20 30 40 50 60
Hm Hft Hm Hft
SXM 65-25 20
DXM 40-40 20
6 6
ND 65-50Hz ND 40-50Hz
2
5 5 2
15 15
4 4

3 1 10 3 1 10

2 2
5 5
1 1

0 0
Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Qm3/h 2 4 6 8 10 12 14 16 18
Ql/min 50 100 150 200 250 300 350 400 450 500 Ql/min 50 100 150 200 250 300
Ql/s 1 2 3 4 5 6 7 8 Ql/s 1 2 3 4 5

Imp. gpm 20 40 60 80 100 120 Imp. gpm 20 30 40 50 60 70


Hm Hft Hm Hft
9 SXM 65-50 30 10 DXM 40-80
ND 50-50Hz 9 ND 40-50Hz 30
8
2 25
8
7 2 25
7
6 20
6 20
5 1
15 5
4 1 15
4
3 10 10
3
2 2
5 5
1 1
0 0 3
Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Qm /h 2 4 6 8 10 12 14 16 18 20
Ql/min 100 200 300 400 500 Ql/min 50 100 150 200 250 300
Ql/s 1 2 3 4 5 6 7 8 9 Ql/s 1 2 3 4 5

Imp. gpm 40 60 80 100 120 140 160 180 200 Imp. gpm 20 30 40 50 60 70 80 90 100
Hm Hft Hft
Hm
7
SXM 80-25 3.5 DXM 50-25 12
ND 80-50Hz ND 50-50Hz
6 20 3 10

5 2 2.5 2 8
15
4 2
6
1
3 10 1.5
1 4
2 1
5
1 0.5 2

0 0
Qm3/h 10 15 20 25 30 35 40 45 50 55 Qm3 /h 4 6 8 10 12 14 16 18 20 22 24 26 28
Ql/min 100 200 300 400 500 600 700 800 900 Ql/min 50 100 150 200 250 300 350 400 450
Ql/s 2 4 6 8 10 12 14 Ql/s 1 2 3 4 5 6 7

11
SCX-DCX - SXM-DXM

DXM - TWIN CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz


Imp. gpm 20 30 40 50 60 70 80 Imp. gpm 20 40 60 80 100 120
Hm Hft Hm Hft
7 DXM 50-50 9 DXM 65-50 30
ND 50-50Hz 8 ND 65-50Hz
6 20 25
2 7 2
5
6 20
15 1
4 1 5
15
3 10 4
3 10
2
5 2
1 5
1
0 0
Qm3/h 4 6 8 10 12 14 16 18 20 22 24 Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
Ql/min 50 100 150 200 250 300 350 400 Ql/min 100 200 300 400 500
Ql/s 1 2 3 4 5 6 Ql/s 1 2 3 4 5 6 7 8 9

Imp. gpm 20 40 60 80 100 Imp. gpm 40 60 80 100 120 140 160 180 200
Hm Hft Hm Hft
11 DXM 50-90 35 7 DXM 80-25
10 ND 50-50Hz ND 80-50Hz
9 30 6 20

8 2 5 2
25
7 15
6 20 4
5 1 10
1 15 3
4
3 10 2
2 5
5 1
1
0 0
Qm3/h 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Qm3 /h 10 15 20 25 30 35 40 45 50 55
Ql/min 50 100 150 200 250 300 350 400 450 500 Ql/min 100 200 300 400 500 600 700 800 900
Ql/s 1 2 3 4 5 6 7 8 Ql/s 2 4 6 8 10 12 14

Imp. gpm 20 30 40 50 60 70 80 90 100


Hm Hft
DXM 65-25
6 20
ND 65-50Hz
2
5
15
4

3 10
1
2
5
1

0
Qm3 /h 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Ql/min 50 100 150 200 250 300 350 400 450 500
Ql/s 1 2 3 4 5 6 7 8

12
SCX-DCX - SXM-DXM

ELECTRICAL DATA AND DIMENSIONS - SCX - THREE-PHASE 50 Hz

Bosses for wall


L1 P1 mounting Suction-discharge flanges
PN 16 - EN 1092-2
Ø1/8" Pg9
ND D c g holes
Pg13.5 3 x M10
depth 25 nxØ mm mm mm nxØ
H1
40 150 110 88 4 x 19
Y1
H Y c D 50 165 125 102 4 x 19
65 185 145 122 4 x 19
= = 80 200 160 138 8 x 19
Ø1/8"
pressure X ND
gauge * SCX 32-80: Casing with 2”
Drilling of 3 bosses g
L P on request male threading for connection by
union 3342.

ORDER M O T O R P U M P REPLACEMENTS
REFERENCE P2 speed P1 full load current ports L H P H1 L1 P1 X Y
Y1 mass MOTOR HYDRAULIC
posi- in A 3-phase (approx.) HEAD POUCH
W tion rpm Wmin Wmax 230V 400V ND mm mm mm mm mm mm mm mm mm kg ORDER REF. ORDER REF.
1 1900 121 190 0.40 0.35
SCX 32-80 180 2 2280 140 250 0.65 0.45 32 142 180 229 103 73 185 ---- ---- .... 7 RL 180-2 PHE 01
3 2665 180 325 1.15 0.65
1 1700 135 210 0.40 0.35
SCX 40-40 180 2 2060 165 285 0.70 0.50 40 155 250 269 125 80 194 75 147 38 12 RL 180-2 PHE 02
3 2580 205 390 1.30 0.75
1 2050 225 350 0.70 0.60
SCX 40-80 350 2 2390 270 440 1.15 0.75 40 171 250 292 125 90 217 90 90 40 16 RL 350-2 PHE 03
3 2730 340 550 1.95 1.10
1 1800 150 200 0.40 0.35
SCX 50-25 180 2 2130 180 270 0.70 0.45 50 178 280 283 140 95 200 85 162 125 14 RL 180-2 PHE 04
3 2620 230 360 1.20 0.70
1 2180 225 315 0.70 0.55
SCX 50-50 350 2 2480 270 390 1.05 0.70 50 174 280 308 140 91 225 90 90 40 18 RL 350-2 PHE 05
3 2770 355 485 2.00 1.15
1 1930 300 475 0.95 0.80
SCX 50-90 450 2 2260 360 620 1.60 1.05 50 189 280 306 140 101 223 90 90 40 19 RL 450-2 PHE 06
3 2660 455 810 2.55 1.50
1 2020 285 345 0.75 0.60
SCX 65-25 350 2 2350 365 440 1.20 0.75 65 204 340 327 170 111 234 104 90 40 22 RL 350-2 PHE 07
3 2720 435 570 2.00 1.15
1 2200 460 610 1.25 1.05
SCX 65-50 570 2 2510 540 750 2.05 1.30 65 218 340 349 170 118 256 104 90 40 26 RL 570-2 PHE 08
3 2810 640 870 2.90 1.65
1 2240 660 1000 2.25 1.75
SCX 65-90 1100 2 2510 770 1230 3.30 2.10 65 218 340 349 170 118 256 104 90 40 28 RL 1100-2 PHE 09
3 2800 900 1470 4.75 2.75
1 2060 510 650 1.35 1.15
SCX 80-25 570 2 2370 620 850 2.30 1.50 80 244 360 358 180 135 258 135 95 40 29 RL 570-2 PHE 10
3 2740 720 1040 3.25 1.85
1 2240 830 980 2.25 1.75
SCX 80-50 1100 2 2490 1000 1260 3.35 2.15 80 244 360 358 180 135 258 135 95 40 31 RL 1100-2 PHE 11
3 2780 1180 1530 5.00 2.90
1 2480 1150 1900 5.60 3.25
SX 1801 2200 80 275 360 403 170 147 294 --- --- --- 46 RA 2200-2 PHE 12
2 2880 1650 2600 10.70 6.20
1 2500 1550 2600 7.80 4.50
SX 1802 2500 2 2900 2250 3550 12.70 7.30 80 275 360 403 170 147 294 --- --- --- 48 RA 2500-2 PHE 13

13
SCX-DCX - SXM-DXM

ELECTRICAL DATA AND DIMENSIONS - DCX - THREE-PHASE 50 Hz

Bosses for wall


mounting
L1 P1
Ø1/8"
Pg9
Pg13,5
Suction-discharge flanges
nxØ
H1 3 x M10 depth 25 PN 16
= = EN 1092-2
H Y1
Ø1/8" Y ND D c g holes
bleed
Ø1/8"
mm mm mm nxØ
pressure 40 150 110 88 4 x 19
gauge ND
L P X g 50 165 125 102 4 x 19
Drilling of 3 bosses on request c 65 185 145 122 4 x 19
D 80 200 160 138 8 x 19

ORDER M O T O R P U M P REPLACEMENTS
REFERENCE P2 speed P1 full load current ports L H P H1 L1 P1 X Y Y1 mass MOTOR HYDRAULIC
posi- in A, 3-phase (approx.) HEAD POUCH
W tion rpm Wmin Wmax 230V 400V ND mm mm mm mm mm mm mm mm mm kg ORDER REF. ORDER REF.
1 1700 140 220 0.45 0.40
DCX 40-40 180 2 2060 175 300 0.75 0.50 40 297 250 269 135 154 194 173 108 11 20 RL 180-2 PHE 02
3 2580 215 410 1.35 0.80
1 2000 240 360 0.75 0.60
DCX 40-80 350 2 2330 285 460 1.20 0.80 40 350 250 292 135 178 217 225 132 35 29 RL 350-2 PHE 03
3 2710 360 590 2.00 1.15
1 1800 160 210 0.45 0.40
DCX 50-25 180 2 2130 190 285 0.75 0.50 50 336 280 283 155 178 200 225 132 25 23 RL 180-2 PHE 04
3 2620 240 380 1.25 0.75
1 2140 225 325 0.70 0.55
DCX 50-50 350 2 2450 265 405 1.10 0.70 50 348 280 308 160 179 225 225 132 30 31 RL 350-2 PHE 05
3 2760 340 510 1.85 1.05
1 1890 300 490 0.95 0.80
DCX 50-90 450 2 2220 370 650 1.60 1.05 50 390 280 306 155 198 223 228 157 50 33 RL 450-2 PHE 06
3 2650 470 825 2.65 1.55
1 2020 310 345 0.75 0.60
DCX 65-25 350 2 2350 390 435 1.20 0.75 65 414 340 327 185 215 234 225 162 25 37 RL 350-2 PHE 07
3 2720 490 560 2.00 1.15
1 2120 470 630 1.30 1.10
DCX 65-50 570 2 2460 555 790 2.20 1.35 65 432 340 349 185 223 256 225 162 25 45 RL 570-2 PHE 08
3 2800 660 915 3.00 1.75
1 2180 670 1020 2.35 1.75
DCX 65-90 1100 2 2490 780 1260 3.35 2.15 65 432 340 349 185 223 256 225 162 25 49 RL 1100-2 PHE 09
3 2780 910 1520 5.10 2.95
1 2050 520 650 1.40 1.20
DCX 80-25 570 2 2360 630 860 2.35 1.50 80 480 360 358 205 249 258 240 180 43 51 RL 570-2 PHE 10
3 2730 730 1050 3.30 1.95
1 2230 840 1050 2.30 1.80
DCX 80-50 1100 2 2480 1020 1300 3.40 2.20 80 480 360 358 205 249 258 240 180 43 55 RL 1100-2 PHE 11
3 2770 1215 1700 5.35 3.10
1 2480 1350 1900 5.60 3.25 PHE 12-mot.1
DX 2801 2200 2 2870 2000 2700 11.00 6.40 80 600 360 394 190 300 294 358 196 44 86 RA 2200-2 PHE 14-mot.2
1 2470 2000 2700 8.10 4.70 PHE 13-mot.1
DX 2802 2500 80 600 360 394 190 300 294 358 196 44 90 RA 2500-2 PHE 15-mot.2
2 2890 2700 3600 13.00 7.50

14
SCX-DCX - SXM-DXM

ELECTRICAL DATA AND DIMENSIONS - SXM - DXM - SINGLE-PHASE 50 Hz


P1
L1 SXM Bosses for wall mounting
Ø1/8" Pg9
Pg13,5 nxØ
H1 3 x M10
depth 25 Suction-discharge flanges
H PN 16 - EN 1092-2
Y1 c D
Y ND D c g holes
Ø1/8" mm mm mm nxØ
pressure = =
gauge ND 40 150 110 88 4 x 19
L P X 50 165 125 102 4 x 19
g
Drilling of 3 bosses 65 185 145 122 4 x 19
P1 on request nxØ
L1 DXM 80 200 160 138 8 x 19
Ø1/8" Pg9
Pg13,5
H1
3 x M10 depth 25
H Y = =
Ø1/8" Y1
bleed * SXM 32-80: Casing with 2"
Ø1/8" Y ND
pressure
male threading for connection by
gauge g union 3342.
P c
L
X D

ORDER M O T O R P U M P REPLACEMENTS
REFERENCE P2 capa- speed P1 full load current ports L H P H1 L1 P1 X Y Y1 mass MOTOR HYDRAULIC
citor posi- in A, 3-phase (approx.) HEAD POUCH
W µF tion rpm Wmin Wmax 230V ND mm mm mm mm mm mm mm mm mm kg ORDER REF. ORDER REF.
1 1950 180 315 1.45
SXM 32-80 180 8x400V 32 142 180 228 090 73 185 ----- ----- ---- 7 RA 180-2 M PHE 01
2 2680 230 340 1.50
1 1470 240 405 1.80
SXM 40-40 180 8x400V 40 155 250 268 125 80 193 75 147 38 12 RA 180-2 M PHE 02
2 2530 240 410 1.80
1 2010 350 590 2.95
SXM 40-80 350 16x400V 40 171 250 292 125 90 217 90 90 40 16 RA 350-2 M PHE 03
2 2730 450 665 3.05
1 1660 220 345 1.60
SXM 50-25 180 8x400V 50 178 280 283 140 95 200 85 162 125 14 RA 180-2 M PHE 04
2 2600 260 385 1.70
1 2360 315 480 2.50
SXM 50-50 350 16x400V 50 174 280 308 140 91 225 90 90 40 18 RA 350-2 M PHE 05
2 2800 400 590 2.75
1 1960 400 760 3.65
SXM 50-90 450 25x400V 50 190 280 306 140 101 223 90 90 40 19 RA 450-2 M PHE 06
2 2720 540 895 3.90
1 2090 460 580 2.80
SXM 65-25 350 16x400V 65 204 340 327 170 111 234 104 90 40 22 RA 350-2 M PHE 07
2 2730 545 675 3.15
1 2290 525 820 3.80
SXM 65-50 570 25x400V 65 218 340 349 170 118 256 104 90 40 26 RA 570-2 M PHE 08
2 2775 715 950 4.10
1 2060 615 840 4.10
SXM 80-25 570 25x400V 80 244 360 358 180 135 258 135 95 40 29 RA 570-2 M PHE 10
2 2720 760 1040 4.60
1 1470 240 425 1.90
DXM 40-40 180 8x400V 40 297 250 268 135 154 193 173 108 11 20 RA 180-2 M PHE 02
2 2530 240 430 1.90
1 1990 350 600 3.00
DXM 40-80 350 16x400V 40 350 250 292 135 178 217 225 132 35 29 RA 350-2 M PHE 03
2 2720 450 680 3.20
1 1660 220 360 1.70
DXM 50-25 180 8x400V 50 336 280 283 155 178 200 225 132 25 23 RA 180-2 M PHE 04
2 2600 260 405 1.80
1 2270 320 520 2.50 50 348 280 308 160 179 225 225 132 30 31 RA 350-2 M PHE 05
DXM 50-50 350 16x400V
2 2780 410 595 2.90
1 1800 450 805 3.90
DXM 50-90 450 25x400V 50 390 280 306 155 198 223 228 157 50 33 RA 450-2 M PHE 06
2 2700 590 935 4.10
1 2080 540 595 3.00
DXM 65-25 350 16x400V 65 414 340 327 185 215 234 225 162 25 37 RA 350-2 M PHE 07
2 2740 600 675 3.15
1 2245 505 790 3.85
DXM 65-50 570 25x400V 65 432 340 349 185 223 256 225 162 25 45 RA 570-2 M PHE 08
2 2765 680 950 4.10
1 2110 595 810 3.95
DXM 80-25 570 25x400V 80 480 360 358 205 249 258 240 180 43 51 RA 570-2 M PHE 10
2 2735 745 975 4.40

15
SCX-DCX - SXM-DXM

PRESSURE GAUGE KIT FEATURES

a) Electrical data
- Three-phase 230 V or 400 V - 50 Hz.
- Single-phase 230 V - 50 Hz with built-in
capacitor.
- Single and three-phase motors must
have a protection.
- Connection to the terminal box via
stuffing box, inlet on left or right.

b) Installation
- Direct on piping, motor shaft always hori-
zontal.
- Connection to the installation: welded,
round counter-flanges (not included).

Differential pressure gauge kit c) Packaging


• For single and twin-head pumps - Supplied with gaskets and bolts, without
• Rapid connection without welding, to ports provided on flanges. counter-flanges.

KIT includes: d) Maintenance


- 0-6 or 0-16 bar glycerin bath pressure gauge, - Replacement of motor head and
- isolating cocks, hydraulic parts (see tables for order ref.).
- unions and connecting tubes,
- bleed.
Supplied in pouch with installation instructions.
OPTIONS & ACCESSORIES
ORDER REF.: PRESS KIT 6 or
PRESS KIT 16 • Motor protection circuit-breaker (SCX).
• Motor control and protection box (DCX).
• Speed controller box.
BLANK COVER • Blank off cover (DCX).
• Pressure gauge kit.
REPLACEMENT OF MOTOR HEAD AND
Optional: cover + gasket
HYDRAULIC PARTS:
• Welded round counter-flanges, unions.
• Isolating valves.
Supplies: • Anti-vibration sleeves, etc.
• bare shaft motor
• hydraulic pouch with:
– impeller + circlip
– motor attachment screws and Allen key
• mounting instructions.
Order ref.: see tables on preceding pages.

type of twin-head ORDER REF.


circulator BLANK COVER
DCX 40-40 - DXM 40-40
Blank cover with gasket for twin-head COUV. 32
pumps DCX 50-25 - DXM 50-25
DCX 40-80 - DXM 40-80
If one pump fails, blanks the opening left DCX 50-50 - DXM 50-50
COUV. 42
by the removal of the hydraulic assembly DCX 50-90 - DXM 50-90
and motor from the pump casing. DCX 65-25 - DXM 65-25
DCX 65-50 - DXM 65-50
During troubleshooting, the standby pump DCX 65-90
is started and keeps the installation in DCX 80-25 - DXM 80-25
COUV. 52
operation.
DCX 80-50
DX 2801 - DX 2802 COUV. 6

16

53 bd de la République - Espace Lumière - Bât. 6 - 78403 Chatou Cedex FRANCE


Tel: +33 (0)1 30 09 82 39 - Fax: +33 (0)1 30 09 82 34 - www.salmson.com

You might also like