You are on page 1of 1

DROP TEST OF ROCK PHOSPHATE WEIGHT METER TOWER B

Date - 22 / 11 / 2022
P.Net Bascule
Ordre chargement Global avant Global après Écart global SDC avant SDC après Écart SDC Partiel A
(Acid) Difference Weight
Truck Loading Meter with respect Remarks
Totalizer Totalizer Control Room Control Room Difference Control Weigh Bridge to Weigh bridge MT
Truck NO Totalizer After Weight meter
Before Difference MT Before After Room Totalizer MT reading ( Acid ) MT
Reading MT

Test Before Calibration & Correction

N°1 TH3937-E 11 400927 400937 10 11.23 11.4 -0.17


691268 691279

N°2 TH3937-E 691279 691290


11 400937 400948 11 10.78 10.94 -0.16

N°3TH3937-E 691290 691303


13 400948 400960 12 13.03 13.35 -0.32

Total = 35 33 35.04 35.69 -0.65

% Error with respect to weigh bridge = -1.82

Test After Correction and Calibration

N°1 th-3937-E 12 11 12.11 12.2 -0.09


691326 691338 400983 400994

N°2 TH-1529-E 691338 691347


9
400994 401003
9 9.21 9.25 -0.04

N°3 TH-1529-E 691369 691379


10
401025 401034
9 9.56 9.6 -0.04

Total = 31 29 30.88 31.05 -0.17

% Error with respect to weigh bridge = -0.55