Professional Documents
Culture Documents
Company No: 380315-T FROM BANDAR UTAMA TO JOHAN SETIA (PACKAGE GS01)
380315-T
Soil properties applied to geotechnical engineering WONG KIM YUEN
Technical Manager
Ref: L180207 Date: 16.10.2018 SUMMARY OF LABORATORY TEST RESULTS
ROCK UU TRIAXIAL 1-DIMENSIONAL MECHANICAL AND
BH Sample UCT POINT UCT COMPRESSION CONSOLIDATION CHEMICAL TESTS ATTERBERG LIMITS HYDROMETER ANALYSIS
No No DEPTH MC LOAD SG C ø Pc Cc OM SO3 Cl pH LL PL PI LS CLAY SILT SAND GRAVEL
m % N/mm² N/mm² kN/m² kN/m² Degree kN/m² % % % % % % % % % % %
CBH-DU-27 UD1 3.00 BRITTLE 33 22 11 25 16 51 8
D5 6.00 49 26 23 25 18 52 5
D7 9.00 NP NP NP 6 15 41 38
D9 12.00 57 30 27 24 41 30 5
D11 15.00 43 27 16 12 38 37 13
D13 18.00 NA NA NA 16 39 45
D15 21.00 39 26 13 10 29 37 24
D18 25.50 39 27 12 11 36 41 12
D21 30.00 37 25 12 13 34 37 16
D23 33.00 34 25 9 10 19 46 25
D25 36.00 31 24 7 10 30 43 17
C1 38.70 32.10
C3 41.70 109.30
D4 4.50 50 30 20 22 30 44 4
D6 7.50 47 29 18 10 37 51 2
D8 10.50 41 28 13 11 32 54 3
D10 13.50 36 29 7 12 32 47 9
D15 21.00 NA NA NA 19 51 30
C3 27.10 87.40
C6 31.60 91.80
D4 9.00 36 26 10 6 25 46 23
D6 12.00 7 18 47 28
D7 13.50 4 23 49 24
C5 17.70 75.20
C6 19.20 72.60
D3 3.00 NA NA NA 8 69 23
D6 7.50 4 26 59 11
D8 10.50 3 24 60 13
D10 13.50 19 64 17
C1 15.20 4.00
C5 21.20 61.80
D3 4.50 69 25 44 26 25 36 13
D4 6.00 4 22 61 13
D6 9.00 9 66 25
C1 10.00 82.7
D4 6.00 3 54 43
D6 9.00 9 30 45 16
D9 13.50 4 20 67 9
D3 4.50 12 82 6
D5 7.50 4 29 56 11
D7 10.50 5 29 56 10
C1 11.50 78.7
C2 13.00 18.8
D4 6.00 15 65 20
C1 7.50 132.3
C3 10.50 127.3
D5 7.50 7 18 64 11
C3 12.00 96
C5 15.00 99.2
D2 4.50 4 18 57 21
C1 9.00 34.2
C5 15.00 92.1
C3 13.50 8.04
C4 15.00 72.4
Borehole No. CBH-DU-27 CBH-DU-27 CBH-DU-27 CBH-DU-27 CBH-DU-27 CBH-DU-27 CBH-DU-27 CBH-DU-27 CBH-DU-27
Container No. 342 313 841 1076 845 425 1417 D 575
Wt of wet soil + container g 126.74 97.37 71.70 93.60 82.49 71.61 106.81 121.69 85.30
Wt of dry soil + container g 99.26 71.10 51.57 70.21 64.34 55.49 81.17 94.89 68.34
Wt of container g 18.38 15.07 15.07 15.14 18.26 15.07 14.89 15.12 14.95
Wt of dry soil g 80.88 56.03 36.50 55.07 46.08 40.42 66.28 79.77 53.39
Wt of water g 27.48 26.27 20.13 23.39 18.15 16.12 25.64 26.80 16.96
Moisture content, w1 % 33.98 46.89 55.15 42.47 39.39 39.88 38.68 33.60 31.77
Factor 0.984 1.039 1.036 1.020 0.984 0.984 0.968 1.000 0.961
LL = w1 x factor 33 49 57 43 39 39 37 34 31
PLASTIC LIMIT (PL) - Clause 5.3
Container No. 850 330 85 905 413 1046 398 58 464
Wt of wet soil + container g 21.48 22.31 21.29 21.13 20.66 21.43 21.36 25.12 23.45
Wt of dry soil + container g 20.30 20.85 19.84 19.83 19.47 20.18 20.12 23.75 21.86
Wt of container g 14.82 15.15 14.93 14.98 14.90 15.54 15.22 18.23 15.19
Wt of dry soil g 5.48 5.70 4.91 4.85 4.57 4.64 4.90 5.52 6.67
Wt of water g 1.18 1.46 1.45 1.30 1.19 1.25 1.24 1.37 1.59
PL = moisture content, w2 22 26 30 27 26 27 25 25 24
Sample No. D2 D4
Receive Date. 19.07.18 19.07.18
Test Date. 20.07.18 20.07.18
LIQUID LIMIT (LL) - Clause 4.4
*NS=Natural State / P=Passing 425µm NS NS
One-Point Cone (15 to 25mm Drop) 18 21
Container No. 53
Wt of wet soil + container g 117.73
Wt of dry soil + container g 86.54
Wt of container g 15.08
Wt of dry soil g 71.46
Wt of water g 31.19
Moisture content, w1 % 43.65
Factor 1.039
LL = w1 x factor 45
PLASTIC LIMIT (PL) - Clause 5.3
Container No. 85
Wt of wet soil + container g 22.23
Wt of dry soil + container g 20.91
Wt of container g 14.88
Wt of dry soil g 6.03
Wt of water g 1.32
PL = moisture content, w2 22
Sample No C1 C3
Depth, m 38.70 41.70
Rock Type GRANITE GRANITE
Moisture Condition
Length / Diameter Ratio 2.0 2.0
Diameter (d), mm 51.98 51.71
Trimmed Length (h), mm 104.22 105.31
Weight of Core, g 559.72 582.50
3
As Received Density, Mg/m 2.530 2.633
Time to failure sec 01:28 01:18
Load, kN 68.2 229.1
2
Measured Strength (Ca), N/mm 32.1 109.0
Corrected Ca
C= 2
Strength d N/mm 32.1 109.3
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Sample No C3 C6
Depth, m 27.10 31.60
Rock Type GRANITE GRANITE
Moisture Condition
Length / Diameter Ratio 2.0 2.0
Diameter (d), mm 51.65 51.66
Trimmed Length (h), mm 104.96 105.16
Weight of Core, g 568.32 571.90
3
As Received Density, Mg/m 2.583 2.594
Time to failure sec 01:05 01:27
Load, kN 182.9 192.0
2
Measured Strength (Ca), N/mm 87.3 91.6
Corrected Ca
C= 2
Strength d N/mm 87.4 91.8
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Sample No C5 C6
Depth, m 17.70 19.20
Rock Type GRANITE GRANITE
Moisture Condition
Length / Diameter Ratio 2.0 2.1
Diameter (d), mm 52.18 51.90
Trimmed Length (h), mm 106.89 106.91
Weight of Core, g 584.07 586.70
3
As Received Density, Mg/m 2.554 2.593
Time to failure sec 01:39 02:08
Load, kN 160.5 153.0
2
Measured Strength (Ca), N/mm 75.0 72.3
Corrected Ca
C= 2
Strength d N/mm 75.2 72.6
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Borehole No CBH-OU-02
Sample No C5
Depth, m 21.20
Rock Type GRANITE
Moisture Condition
Length / Diameter Ratio 2.1
Diameter (d), mm 52.19
Trimmed Length (h), mm 107.12
Weight of Core, g 589.02
3
As Received Density, Mg/m 2.569
Time to failure sec 02:70
Load, kN 131.9
2
Measured Strength (Ca), N/mm 61.6
Corrected Ca
C= 2
Strength d N/mm 61.8
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Borehole No CBH-DU-12
Sample No C1
Depth, m 10.00
Rock Type GRANITE
Moisture Condition
Length / Diameter Ratio 2.1
Diameter (d), mm 51.52
Trimmed Length (h), mm 107.12
Weight of Core, g 576.73
3
As Received Density, Mg/m 2.582
Time to failure sec 01:78
Load, kN 171.7
2
Measured Strength (Ca), N/mm 82.3
Corrected Ca
C= 2
Strength d N/mm 82.7
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Sample No C1 C2
Depth, m 11.50 13.00
Rock Type GRANITE GRANITE
Moisture Condition
Length / Diameter Ratio 2.1 1.9
Diameter (d), mm 51.47 51.49
Trimmed Length (h), mm 106.64 98.76
Weight of Core, g 568.83 519.66
3
As Received Density, Mg/m 2.563 2.526
Time to failure sec 01:89 01:88
Load, kN 163.1 39.4
2
Measured Strength (Ca), N/mm 78.4 18.9
Corrected Ca
C= 2
Strength d N/mm 78.7 18.8
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Sample No C1 C3
Depth, m 7.50 10.50
Rock Type GRANITE GRANITE
Moisture Condition
Length / Diameter Ratio 2.1 2.1
Diameter (d), mm 51.56 51.35
Trimmed Length (h), mm 106.68 106.70
Weight of Core, g 578.22 580.21
3
As Received Density, Mg/m 2.595 2.625
Time to failure sec 02:37 01:85
Load, kN 275.3 262.6
2
Measured Strength (Ca), N/mm 131.8 126.7
Corrected Ca
C= 2
Strength d N/mm 132.3 127.3
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Sample No C3 C5
Depth, m 12.00 15.00
Rock Type GRANITE GRANITE
Moisture Condition
Length / Diameter Ratio 2.1 2.1
Diameter (d), mm 51.65 51.61
Trimmed Length (h), mm 107.52 106.08
Weight of Core, g 584.63 578.25
3
As Received Density, Mg/m 2.594 2.605
Time to failure sec 01:79 01:64
Load, kN 200.2 206.9
2
Measured Strength (Ca), N/mm 95.5 98.9
Corrected Ca
C= 2
Strength d N/mm 96.0 99.2
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Sample No C1 C5
Depth, m 9.00 15.00
Rock Type GRANITE GRANITE
Moisture Condition
Length / Diameter Ratio 2.1 2.1
Diameter (d), mm 51.48 51.60
Trimmed Length (h), mm 107.24 106.83
Weight of Core, g 582.27 580.63
3
As Received Density, Mg/m 2.608 2.598
Time to failure sec 01:68 01:30
Load, kN 70.9 192.0
2
Measured Strength (Ca), N/mm 34.0 91.8
Corrected Ca
C= 2
Strength d N/mm 34.2 92.1
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Borehole No CBH-DU-17A
Sample No C4
Depth, m 15.00
Rock Type GRANITE
Moisture Condition
Length / Diameter Ratio 2.1
Diameter (d), mm 51.66
Trimmed Length (h), mm 105.96
Weight of Core, g 580.36
3
As Received Density, Mg/m 2.612
Time to failure sec 02:50
Load, kN 151.4
2
Measured Strength (Ca), N/mm 72.2
Corrected Ca
C= 2
Strength d N/mm 72.4
0.88 + 0.24
h
Before
Test
After
Test
Notes: The test reported herein have been reported in accordance with ASTM D7012-14 (Method C).
The desirable length to diameter ratio 2.0:1 and 2.5:1. Any deviation with the ratio may result in differ from the results obtained
from a test specimen meets the requirements.
The corrected strength is for an equivalent 2:1 (height:diameter) ratio test specimen according to ISRM
The results relate only to the sample received.
This document shall not be reproduced except in full, without written approval of the laboratory.
Approved Signatory
380315-T
Test Orientation U
Moisture Condition C
Point Load Strength, I s (N/mm2) <0.03 ≥0.03<0.1 ≥0.1<0.3 ≥0.3<1.0 ≥1.0<3.0 ≥3.0<10.0 >10.0
Strength Designation Extremely Low Very Low Low Medium High Very High Extremely High
Sample No C3
Depth, m 13.50
Received Date 01.09.2018
Test Orientation U
Moisture Condition C
Point Load Strength, I s (N/mm2) <0.03 ≥0.03<0.1 ≥0.1<0.3 ≥0.3<1.0 ≥1.0<3.0 ≥3.0<10.0 >10.0
Strength Designation Extremely Low Very Low Low Medium High Very High Extremely High
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
100
90
80
70
Percent Passing
60
50
40
30
20
10
0
0.001 0.01 0.1 1 10 100
SKETCH OF
FAILURE
CONDITION >>>
90
Theoretical
80 ---- Unsaturated
2
70
SHEAR STRESS, kN/m
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
NORMAL STRESS, kN/m2
Partially
BS1377: 1990, Part 7, Clause 8
Saturated Total c= 9 kN/m² Approved Signatory
Stress MS1056: 2005, Clause 9
ø= 3º
NOTES:
Theoretical
Total Stress
c= 12 kN/m² The results relate only to the sample received. 380315-T
ø= 0º This document shall not be reproduced except
REPORT FORM: RF-UU-03 in full, without the written approval of the WONG KIM YUEN Issue Date
(ver. 06/2018) laboratory. Technical Manager 04.09.2018
http://soilpro.com.my/quality.html
SOILPRO TECHNICAL SERVICES SDN BHD (380315-T)
16 Jalan TIB-1/17, Taman Industri Bolton, 68100 Batu Caves, Selangor, Malaysia
Tel: 603-6188 6975, 03-6188 9964 Fax: 603-6185 5903
eMail: labtest@soilpro.com.my Website: http://soilpro.com.my
TEST REPORT Page 1 of 1
UU TRIAXIAL COMPRESSION TEST Lab Ref: L180207/UU
Project: CONSTRUCTION & COMPLETION OF LIGHT RAIL LINE 3 (LRT3) SampleNo.: CBH-DU-14/UD1
Location: FROM BANDAR UTAMA TO JOHAN SETIA (PACKAGE GS01) Depth, m. : 3.50
Customer: Gagasan Teguh Sdn Bhd Receive Date: 01.09.2018
No.29-1, Jalan PUJ 3/5, Taman Puncak Jalil Test Date: 03.09.2018
43300 Seri Kembangan, Selangor Tested by: Nor
Specimen A Specimen B Specimen C
CELL PRESSURE >>>
30 kPa 60 kPa 120 kPa
SKETCH OF
FAILURE
CONDITION >>>
120
Theoretical
---- Unsaturated
100
2
SHEAR STRESS, kN/m
80
60
40
20
0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280
NORMAL STRESS, kN/m2
Partially
BS1377: 1990, Part 7, Clause 8
Saturated Total c= 23 kN/m² Approved Signatory
Stress MS1056: 2005, Clause 9
ø= 12 º
NOTES:
Theoretical
Total Stress
c= 46 kN/m² The results relate only to the sample received. 380315-T
ø= 0º This document shall not be reproduced except
REPORT FORM: RF-UU-03 in full, without the written approval of the WONG KIM YUEN Issue Date
(ver. 06/2018) laboratory. Technical Manager 04.09.2018
http://soilpro.com.my/quality.html