You are on page 1of 9

ENGINEERING PROCUREMENT & PROJECT MANAGEMENT Date: 11-02-2013

EPPM STANDARD Ref:


Rev: A
DATASHEET
Sheet: 1/4

VENTILATOR DATASHEET

A 2/11/2013 AZ

001 03/12
Name Visa Name Visa Name Visa
Rev Date Description
Prepared by Checked by Approved by

001 03/12
ENGINEERING PROCUREMENT & PROJECT MANAGEMENT Date: 11-02-2013
EPPM STANDARD Ref:
Rev: A
DATASHEET
Sheet: 2/4
VENTILATOR DATASHEET

REVISIONS REVISIONS
SHEETS SHEETS
1 31
2 32
3 33
4 34
5 35
6 36
7 37
8 38
9 39
10 40
11 41
12 42
13 43
14 44
15 45
16 46
17 47
18 48
19 49
20 50
21 51
22 52
23 53
24 54
25 55
26 56
27 57
28 58
29 59
30 60

Note : * front page


** this page

REVISION REASON FOR ISSUE

002 03/12
002 03/12
ENGINEERING PROCUREMENT & PROJECT MANAGEMENT Date: 11-02-2013
EPPM STANDARD Ref:
Rev: A
DATASHEET
Sheet: 3/4
VENTILATOR DATASHEET
1
2
3
4
5 Machine Shed Ventillator
6 Service Dry Air
7 Project Data
8 Tag Nb K-102 A/B
9 Quantity 2
10 Site conditions
11 Altitude (m) 418
12 Temperature (°C) Min Max 50
13 Relative humidity (%) Min Max 34
14 Wind velecity (m/s) 50
15 Lightning To be condidered
16 Sol hight (m) 418
17 Soil nature Rocky
18 Seismic Zone Zone 1
19 Technical caracteristic
20 Traited fluid Dry air
21 Flowrate (m3/h) 12000
22 Discharge pressure (Pa) 354
23 Discharge temperature (°C) 40
24 Shed Structure Stuctural frame
25 Plate Corrugated Plate
26 Length (m) ###
#########
27 Width (m) ###
#########
28 Height (m) ###
29 Motor Type Electric
30 Power (Kw) ###
31 Total machine weight (kg) *
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

002 03/12
49
50
51

002 03/12
ENGINEERING PROCUREMENT & PROJECT MANAGEMENT Date: 11-02-2013
EPPM STANDARD Ref:
Rev: A
DATASHEET
Sheet: 4/4
VENTILATOR DATASHEET
1
2
3
4
5
6 DESCRIPTION GENERALE
7 The system should provide forced ventilation in a shed made of metal frame.
The walls of the shed shall be insulated corrugated plates.
8
9 Under normal conditions, the air flow circulation will be ensured by the fan and
10 the windows placed on both sides of the shed.
In case of sandstorm, windows will be closed and the fan will ensure complete
11
ventilation of theoverpressure
- Create A slight shed. " in order to prevent the entry of sand into the
12
building
13 - Ensure air exchange.
14 Sand interceptor Filters must be provided to prevent the entry of sand into the shed during oper
15 The ventilation system shall consist of:
16 - A ventilation unit with body made of sound absorption panels, having a solid structure
17 - A second fan reserve unit
18 - A device For adjusting the flow rate of air including curtain with manual control
19 - A gravitation sand filtration battery
20 - A series of Flanged channels of adduction and distribution of air to hangar with galvanized met
21 - A series of circular diffusers for the vertical distribution of air
22 - A series of overpressure curtain for wall mounting
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

002 03/12
48
49
50
51

002 03/12
during operation.

vanized metal sheet.