CONCRETE COMPRESSIVE STRENGTH TEST REPORT NF EN

12390-3
Number of Test Report 001
Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima
Mix Design ✘ Trial Mix Control Information

Temperature weather /
- Size of specimen 160 x 320 mm
concrete
Pouring date 5/9/2023 Slump test at 0' 9,5 cm
Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Admix150
Quantity(Kg/m3) 450 178.78 574 260 1018 4
Part of Structure
N/A

30A100_RFI_007 EXT
Number notification 30A100_RFI_010 EXT Date of receipt 6/19/2023
30A100_RFI_011 EXT

Curing by Density Strength (Mpa)


Spec. Tag Crushing date Weight (Kg) Load (kN)
days (T/m3) Unit Average
322 15.62 2.43 453.10 22.54
323 7 5/16/2023 15.56 2.42 453.53 22.61 21.85
324 15.30 2.38 409.82 20.39
325 15.52 2.41 539.79 26.85
326 14 5/23/2023 15.58 2.42 380.81 18.94 25.87
327 15.42 2.40 500.30 24.88
328 15.54 2.42 541.88 26.95
329 28 6/6/2023 15.32 2.38 515.68 25.65 26.23
330 15.58 2.42 524.58 26.09

Inspection execution result


ACCEPTED ⃣ REJECTED ⃣ POSTPONED ⃣ CANCELLED ⃣
Remarks :

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature