You are on page 1of 3

CRUSHING TEST REPORT NF EN 12390-3

CONTRACTOR Zerock CTR N° 55 30A100_RFI N°: 065 EXT MIX DESIGN

Oil Storage Tank (B5Mul 1) / Electrical


PROJECT 1st Agri Hub PART OF STRUCTURE TRIAL MIX
Room (A3IF02-A2IF02-A1IF02-C1IF02)

POURING DATE 6/27/2023 ORIGIN OF CONCRETE Zerock Batching plant Loudima INFORMATION ✘

TEMPERATURE 25,1 / 27,6 °C SIZE OF SPECIMEN 16 x 32 cm NUMBER OF SPECIMEN 3

MIX DESIGN CODE 25-XC4-D25-S3-42.5N-SHR-S0/1


COMPOSITION OF CONCRETE CEMENT WATER SAND GRAVEL 1 GRAVEL 2 ADMIXTURE SLUMP TEST SPECIFIED

TYPE 42,5N - 0/1 5/12,5 16/25 ADMIX150 SLUMP TEST 0' 11,9 cm
THEORICAL (Kg/m3) 450 178.78 574 260 1018 4 SLUMP TEST 30'
PRATICAL - - - - - - SLUMP TEST 60'

COMPACTION Vibration CURING Water immersion

COMPRESSIVE
SPECIMEN AGE WEIGHT DENSITY LOAD
CRUSHING DATE STRENGHT FAILURE
REFERENCE
(J) (Kg) (T/m3) (KN) MPa AVERAGE
AH133 28 7/25/2023 16.14 2.51 549.44 27.33 Correct
AH134 28 7/25/2023 16.26 2.53 612.99 30.45 28.28 Correct
AH135 28 7/25/2023 16.28 2.53 544.34 27.07 Correct
Remarks :

Inspectors for : GEOLAB ENI CONGO ZEROCK


Name
Signature
Date
Roulé
Concassé

Correct
Incorrect
Pervibration