You are on page 1of 3

CRUSHING TEST REPORT NF EN 12390-3

CONTRACTOR Zerock CTR N° 51 30A100_RFI N°: 063 EXT MIX DESIGN

Production line shed footings (G9IF01-


PROJECT 1st Agri Hub PART OF STRUCTURE TRIAL MIX
G10IF01-G11IF03-f11IF03-E11IF03)

POURING DATE 6/26/2023 ORIGIN OF CONCRETE Zerock Batching plant Loudima INFORMATION ✘

TEMPERATURE 30,1 / 30,6 °C SIZE OF SPECIMEN 16 x 32 cm NUMBER OF SPECIMEN 3

MIX DESIGN CODE 25-XC4-D25-S3-42.5N-SHR-S0/1


COMPOSITION OF CONCRETE CEMENT WATER SAND GRAVEL 1 GRAVEL 2 ADMIXTURE SLUMP TEST SPECIFIED

TYPE 42,5N - 0/1 5/12,5 16/25 ADMIX150 SLUMP TEST 0' 14 cm


THEORICAL (Kg/m3) 450 178.78 574 260 1018 4 SLUMP TEST 30'
PRATICAL - - - - - - SLUMP TEST 60'

COMPACTION Vibration CURING Water immersion

COMPRESSIVE
SPECIMEN AGE WEIGHT DENSITY LOAD
CRUSHING DATE STRENGHT FAILURE
REFERENCE
(J) (Kg) (T/m3) (KN) MPa AVERAGE
AH115 28 7/24/2023 16.06 2.50 597.34 29.71 Correct
AH116 28 7/24/2023 16.16 2.51 587.67 29.23 30.40 Correct
AH117 28 7/24/2023 16.10 2.50 648.57 32.26 Correct

Remarks :

Inspectors for : GEOLAB ENI CONGO ZEROCK


Name
Signature
Date
Roulé
Concassé

Correct
Incorrect
Pervibration