CONCRETE COMPRESSIVE STRENGHT TEST REPORT NF EN

12390-3
Number of Test Report 140
Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima

Temperature 23,1 / 28,6 °C Size of specimen (16 x 32 cm) x 3


Pouring date 8/14/2023 Slump test at 0' 13,5 cm
Mix Design Code 25-XC4-D25-S3-42.5N-SHR-S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Admix150
Quantity(Kg/m3) 450 178.78 574 260 1018 4
Part of Structure

Production Line Shed / Paving; Electrical Trench cable; Day Bin Blower (BF); Longrin / TR6_F3-F34 wall;
TR4_9-10 wall; TR8_F5-F1 base; TR14_8-9 wall

Number notification 30A100_RFI_139EXT Date of receipt 8/14/2023

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH448
AH449 28 9/11/2023
AH450

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date

Number notification 30A100_RFI_139EXT Date of receipt 8/14/2023

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH448
AH449 28 9/11/2023
AH450

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date