You are on page 1of 3

CRUSHING TEST REPORT NF EN 12390-3

CONTRACTOR Zerock CTR N° 53 30A100_RFI N°: 062 EXT MIX DESIGN


Production line shed footings
PROJECT 1st Agri Hub PART OF STRUCTURE F13B';TB7_A2-A4;TR5_F22; TR9_3- TRIAL MIX
5;F27west base;TR14_A2-A6
POURING DATE 7/17/2023 ORIGIN OF CONCRETE Zerock Batching plant Loudima INFORMATION ✘

TEMPERATURE 24 / 28 °C SIZE OF SPECIMEN 16 x 32 cm NUMBER OF SPECIMEN 3

MIX DESIGN CODE 25-XC4-D25-S3-42.5N-SHR-S0/1


COMPOSITION OF CONCRETE CEMENT WATER SAND GRAVEL 1 GRAVEL 2 ADMIXTURE SLUMP TEST SPECIFIED

TYPE 42,5N - 0/1 5/12,5 16/25 ADMIX150 SLUMP TEST 0' 15,6 cm
THEORICAL (Kg/m3) 450 178.78 574 260 1018 4 SLUMP TEST 30'
PRATICAL - - - - - - SLUMP TEST 60'

COMPACTION Vibration CURING Water immersion

COMPRESSIVE
SPECIMEN AGE WEIGHT DENSITY LOAD
CRUSHING DATE STRENGHT FAILURE
REFERENCE
(J) (Kg) (T/m3) (KN) MPa AVERAGE
AH283 7 7/24/2023 15.80 2.46 436.81 21.73 Correct
AH284 7 7/24/2023 16.08 2.50 490.38 24.39 24.06 Correct
AH285 7 7/24/2023 15.84 2.46 524.12 26.07 Correct
Remarks

Inspectors for : GEOLAB ENI CONGO ZEROCK


Name
Signature
Date
Roulé
Concassé

Correct
Incorrect
Pervibration

You might also like