CONCRETE COMPRESSIVE STRENGTH TEST REPORT NF EN

12390-3
Number of Test Report 108
Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima

Temperature 28.7 / 33.8 °C Size of specimen (16 x 32 cm) x 3

Pouring date 10/16/2023 Slump test at 0' 10 cm


Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Admix150
Quantity(Kg/m3) 450 178.78 574 260 1018 4
Part of Structure

Heliport; 2nd line Production; Shed compressor / Longrin ; Trench ; Footing / -Longrin_A4-A2; -TR22_F11-F31
Wall; -C1-B1-A1-C4-D3-D4-B2-B1-D2-A1-A2

30A100_RFI_215 EXT
Number notification 30A100_RFI_247 EXT Date of receipt 10/15/2023
30A100_RFI_297 EXT

Curing by Density Strength (Mpa)


Spec. Tag Crushing date Weight (Kg) Load (kN)
days (T/m3) Unit Average
AH832 15.84 2.46 389.28 19.36
AH833 7 10/23/2023 15.86 2.47 412.36 20.51 19.12
AH834 15.88 2.47 351.42 17.48
AH838 15.90 2.47 475.74 23.66
AH839 28 11/13/2023 16.06 2.50 366.03 18.20 21.34
AH840 16.06 2.50 445.43 22.15
AH841 16.20 2.52 417.53 20.77
AH842 56 12/11/2023 15.88 2.47 514.10 25.57 24.22
AH843 15.74 2.45 529.35 26.33

Inspection execution result


ACCEPTED ⃣ REJECTED ⃣ POSTPONED ⃣ CANCELLED ⃣
Remarks :

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature