You are on page 1of 1

CONCRETE COMPRESSIVE STRENGTH TEST REPORT NF EN

12390-3
Number of Test Report 121
Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima

Temperature 30.1 / 30.5 °C Size of specimen (16 x 32 cm) x 3

Pouring date 10/31/2023 Slump test at 0' 16 cm


Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Admix150
Quantity(Kg/m3) 450 178.78 574 260 1018 4
Part of Structure

Silo 3; Heliport / Footing / - Base; -Section 01

30A100_RFI_241 EXT
Number notification Date of receipt 11/2/2023
30A100_RFI_277 EXT

Curing by Density Strength (Mpa)


Spec. Tag Crushing date Weight (Kg) Load (kN)
days (T/m3) Unit Average
AH934 15.72 2.44 530.74 26.40
AH935 7 11/7/2023 15.86 2.47 550.79 27.39 26.14
AH936 16.00 2.49 495.04 24.62
AH937 0.00 0.00
AH938 29 11/29/2023 0.00 0.00 0.00
AH939 0.00 0.00
AH940
AH941 56 12/26/2023 N/A
AH942

Inspection execution result


ACCEPTED ⃣ REJECTED ⃣ POSTPONED ⃣ CANCELLED ⃣
Remarks :

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date