Professional Documents
Culture Documents
REVISIONS REVISIONS
SHEETS A01 A02 SHEETS A01 A02
1* 35
2**
2 36
3 37
4 38
5 39
6 40
7 41
8 42
9 43
10 44
11 45
12 46
13 47
14 48
15 49
16 50
17 51
18 52
19 53
20 54
21 55
22 56
23 57
24 58
25 59
26 60
27 61
28 62
29 63
30 64
31 65
32 66
33 67
34 68
Note : * front page
** this page
Revisions History
Revision Description
A01 Issued for Internal Review
Project Name:
Title: Data Sheet for Depropanizer Air Cooler Document No.:TGP-JE-GTPT-240-RE-DAT-0004 Rev.: A01 Page : 3 of 5
Manufacturer Heat exchanged (Watts) 547712
Model no. Surface/Item-Finned tube (m2) 3062
Customer Bare tube (m2) 127.582
Plant location Tunisia MTD, Eff. (Deg. C) 12.10
Service GTPT-AC-240-002 Transfer rate-Finned (W/m2-K) 25.389
Type draft FORCED Bare tube, service (W/m2-K) 609.370
Bay size (WxL) (m) 2 91 x 9
2.91 9.000
000 Bare tube
tube, clean (W/m2-K) 609.370
No. of bays/Items 1
Title: Data Sheet for Depropanizer Air Cooler Document No.:TGP-JE-GTPT-240-RE-DAT-0004 Rev.: A01 Page : 4 of 5
Design, Material, and Construction (continued)
Header (continued) No./Bundle 184.0
Slope Length (m) 9
Plug material Pitch (mm) 62.000
Gasket material Layout Triangular
Nozzle No. Size Rating/Facing Fin
Inlet 1 4“
4 300#-RF Type Plain round
Outlet 1 3" 300#-RF Material Aluminum 1060 - H14
Vent Thickness (mm) 0.500
Drain Selection temp. (C)
Chemical Cleaning Outside diameter (mm) 57.000
Min. Wall Thk. Fin density (fin/meter) 433.0
Tube ASME Code, Sec. VIII, Div. 1
Material CS Customer Specifications
Tube outside diameter (mm) 25.000
Average wall thickness (mm) 2.5
Mechanical Equipment
Fan RPM
Manufacturer Service factor
No./Bay 3 Enclosure
RPM (Revs/min.) Voltage
Diameter (m) 2.108 Phase
No. of blades Cycle
Angle (degrees) Fan noise level (dB)
Pitch adjustment Speed Reducer
Blade material Type
Hub material Manufacturer
@design temp No./Bay
@min. ambient temp Service factor
Tip speed Speed ratio
Driver Support
Type Vib. switch
Manufacturer Enclosure
No./Bay
Driver
Controls - Air Side
Air recirculation Louvers
Degree control of outlet process temp. Positioner
(Max. Cooling),+/- Signal air pressure (kPa)
Action on control signal failure From To
Fan pitch From To
Louvers Supply air pressure (kPa)
Actuator air supply From To
Fan From To
Shipping
Plot area (WxL) (m) Total (kg)
Bundle weight (kg) Shipping (kg)
Bay (kg)
Project Name:
Title: Data Sheet for Depropanizer Air Cooler Document No.:TGP-JE-GTPT-240-RE-DAT-0004 Rev.: A01 Page : 5 of 5
Inlet Stream Property and Components
NOTES
1. - Materials and Corrosion allowance shalll be confirmed by VENDOR.
2.- VENDOR shall verify, design and provide mechanical and thermal guarantee.
3.- VENDOR shall provide Data Sheet with Complete information
4- Data submitted in this sheet should be confirmed by VENDOR
5 VENDOR should
5.- h ld consider
id extra
t margin
i off heat
h t exchange
h i case heat
area in h t exchange
h ffi i
efficiency l
low d
down ft a long
after l d ti running.
duration i
6. - The VENDOR should provide the max. allowable torque and disposition of nozzles.
7.- Only one is driven by VFD, others are fixed frequency.
8.- In any conditions, the outlet temperature of air cooler bundle shall be lower than 57.5 Deg.C
9.- VENDOR shall confirm that material of fan meet service requirements.
10.- The max. ambient temperature for the motor design and selection is 55 Deg.C
11.- Equipment shall be designed to meet a service life of 25 years, and the packaged equipment shall be suitable for operation at the rated loading for a
continuous period of 3 years.The continous running: 355 days/year.
12.- Over design margin:10% on flowrate& duty, 15% on surface area.