CONT. No.: 1187/EB-GN/DBS-BD01-00 REF. No.: 1187-DS-PM-41-03
Revision Mark
2 SITE: GURREH-JASK (TERMINAL) NO. REQUIRED: 1
3 LOCATION: FIRE WATER PUMPS BUILDING TAG NUMBER:
4 NOTE: INDICATES INFORMATION TO BE COMPLETED BY PURCHASER MANUFACTURER PURCHASER OR MANUFACTURER
5 Fire Water Pumps Building
6 CRANE TYPE: TOP RUNNING UNDER HUNG OTHER
7 CAPACITY: 5,000 Kg SPAN (NOTE 7) m LIFT (NOTE 7) m TRAVEL LENGTH (NOTE 7) m
8 ENVIRONMENT: CRANE LOCATION: INDOOR OUTDOOR BOTH
9 TEMPERATURE: MAX 47.2 O
C MIN 8 O
C SEISMIC ZONE (ZONE 3) WIND DESIGN LOAD(100 km/hr)
10 HAZARDOUS AREA: YES NO IF YES, SPECIFY EXPLOSION PROTECTION
11 ELECTRICAL ENCLOSURE TYPE: IP54 UNUSUAL CONDITIONS: DUST, FUMES, ETC. INSULATION CLASS F TEMP. RISE B
12 PLANT UTILITIES: ELECTRICITY 3 PHASE 50 CYCLE 400 VOLTS BAROMETER PRESSURE bara
13 REMARKS: (NOTE 4)
14 CRANE MOTION: ELECTRICITY AIR MANUAL SPEEDS POWER DUTY
15 HOIST VTS / VTS m/min VTS / VTS (KW) (%)
16 TROLLEY VTS / VTS m/min VTS / VTS (KW) (%)
17 BRIDGE VTS / VTS m/min VTS / VTS (KW) (%)
18 REMARKS: ELECTRICAL MOTORS SHALL BE DUAL SPEED TYPE.
19
20 CONTROL: TYPE (SPECIFY) PUSH BUTTONS FOR 2 SPEEDS (NOTE 6) TEST AND INSPECTION
21 CONTROL LOCATION: CAB FLOOR PENDANT STATION STATIC LOAD TEST (125% OF RATED LOAD)
22 OTHER AT MANUFACTURE’S SHOP
23 BRIDGE SHALL BE FURNISHED BY VENDOR YES NO AT SITE
24 TYPE REQUIRED: (TO BE SUPPLIED BY VENDOR) DYNAMIC LOAD TEST (110% OF SWL)
25 BRIDGE TROLLEY AT MANUFACTURE’S SHOP
26 RUNAWAY COLLECTORS AT SITE
27 RUNAWAY CONDUCTORS LIMIT SWITCHES FUNCTIONAL TEST
28 CABLE REEL LIFTING AND LOWERING
29 FESTOONED CABLE TROLLEY/BRIDGE TRAVEL
30 ITEMS TO BE SUPPLIED BY VENDOR: PACKING/MARKING AT DELIVERY POINT
31 RAIL SWEEP FOR BRIDGES RAIL SWEEP FOR TROLLEYS MATERIAL CERTIFICATES (NOTE 13)
32 BUMPER STOPS FOR BRIDGES BUMPER STOPS FOR TROLLEYS TYPE NDT OF WELDING (NOTE 14)
33 SURFACE PREPARATION YES NO OTHER LIQUID PENETRANT MAG. PARTICLE
34 PAINTING, PRIME PAINT REQUIRED FINISH PAINT REQUIRED RADIOGRAPHIC ULTRASONIC
35 FLOOD LIGHTS REQUIRED, TYPE SPARK RESISTANT CONSTRUCTION BRIDGE DEFLECTION (1/750 OF SPAN)
36 ELECTRIC SPACE HEATER REQUIRED BRAKES FOR HOIST, TROLLEY & BRIDGE SPEED TEST
37 SINGLE POINT LUBRICATION SYSTEM LIMIT SWITCHES (NOTE 5) FULL FUNCTIONAL TEST (WITHOUT LOAD)
38 MAINTENANCE & SERVICE PLATFORMS WARNING LAMP AND SIRENS
39 NAME PLATE FOR ALL COMPONENTS EARTH CONNECTION (NOTE 9)
40 SPARE PARTS FOR PRECOMMISSIONING, COMMISSIONING AND 2 YEARS OF OPERATION
41 INSTALLATION SUPERVISION SPECIAL TOOLS (IF APPLICABLE)
42 JUNCTION BOX, LOCAL PANELS, CABINETS, WIRING AND TERMINATION
43
44 REMARKS:
45
46
47
48
49
50
CONT. No.: 1187/EB-GN/DBS-BD01-00 REF. No.: 1187-DS-PM-41-03
1 NOTES
2
3 1) REFERENCE SPECIFICATION IS "PROJECT SPECIFICATION FOR OVERHEAD AND PORTAL BRIDGE (GANTRY) CRANES, DOC. NO. 1187-00-EB-GN-SP-9078.
4 2) ACCESS LADDER/WALKWAY TO BE PROVIDED (IF REQUIRED).
5 3) MAXIMUM ALLOWABLE SOUND LEVEL SHALL BE LIMITED TO 85 dbA.
6 4) GENERAL FUTURES OF MOTOR SHALL BE ACCORDING TO "PROJECT SPECIFICATION FOR ELECTRICAL LV INDUCTION MOTORS; DOC. NO. 1187-00-EB-EL-SP-6002".
7 5) LIMIT SWITCHES SHALL BE TOTALLY ENCLOSED, HEAVY DUST AND SPLASH PROOF TYPE.
8 6) PUSH BOTTON ENCLOSURE CONTROL FOR MAIN PUMPS SHELTER CRANE SHALL BE FLAME PROOF TYPE , CAST AL. ALLOY OR OTHER APPROVED
9 MATERIAL , WITH FLEXIBLE MULTICORE CABLE CONNECTION.
10 7) FOR FINALIZING CRANE DIMENSIONS AND SUPPLEMENTARY NOTES REFER TO "BASIC ARCHITECTURAL DRAWING FOR FIRE FIGHTING PUMP HOUSE;
11 DWG. NO. 1187-41-EB-AR-DWG-BD4110-01".
12 8) SPEED TORQUE CURVE FOR HOIST SHALL BE SUBMITTED WITH QUOTATION.
13 9) CRANES AND ASSOCIATED METAL STRUCTURES AND EQUIPMENT SHALL BE SUITABLY CONNECTED TO THE MAIN EARTHING NETWORK OF THE PLANT.
14 THE CRANE WHEELS SHALL NOT BE USED AS MEANS OF EARTHING.
15 10) THE ELEVATION OF LOWEST HOOK POSITION WITH RESPECT TO GROUND LEVEL CONSIDERING WHOLE DIFFERENT REQUIREMENT (MAINTENANCE AND ETC.)
16 IS MAX. 1 M ABOVE GROUND LEVEL. VENDOR TO CONFIRM.
17 11) MAX. ALLOWABLE HEIGHT OF CRANE BRIDGE AND ITS AUXILIARIES (RAIL, END CARRIAGE AND CONTROL PANEL) SHALL NOT EXCEED 600 MM
18 BECAUSE OF LIGHTING. VENDOR TO CONFIRM.
19 12) HOIST SHALL BE WIRE ROPE TYPE.
20 13) MATERIAL CERTIFICATE SHALL BE ACCORDING TO LATEST EDITION OF EN 10204 (TYPE 3.1).
21 14) NDT SHALL BE PERFORMED AS PER ASME SEC. V.
22 15) ALL VENDORS AND MANUFACTURERS SHALL BE SELECTED FROM NIOEC AVL.
23 16) THE TYPE OF HOOK SHALL BE SWIVEL TYPE CAPABLE OF FREE ROTATING (HOOK BLOCK) EQUIPPED WITH SPRING SAFETY LATCH.
24 17) DRAWING SHOWING OVERALL DIMENSIONS & CLEARANCES SHALL BE SUBMITTED WITH QUOTATION.
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
CONT. No.: 1187/EB-GN/DBS-BD01-00 REF. No.: 1187-DS-PM-41-03
Revision Mark
2 SITE: GURREH-JASK (TERMINAL) NO. REQUIRED: 1
3 LOCATION: WORKSHOP & WAREHOUSE BUILDING TAG NUMBER:
4 NOTE: INDICATES INFORMATION TO BE COMPLETED BY PURCHASER MANUFACTURER PURCHASER OR MANUFACTURER
5 Workshop & Warehouse building
6 CRANE TYPE: TOP RUNNING UNDER HUNG OTHER
7 CAPACITY: 10,000 Kg SPAN (NOTE 7) m LIFT (NOTE 7) m TRAVEL LENGTH (NOTE 7) m
8 ENVIRONMENT: CRANE LOCATION: INDOOR OUTDOOR BOTH
9 TEMPERATURE: MAX 47.2 O
C MIN 8 O
C SEISMIC ZONE (ZONE 3) WIND DESIGN LOAD (100 km/hr)
10 HAZARDOUS AREA: YES NO IF YES, SPECIFY EXPLOSION PROTECTION
11 ELECTRICAL ENCLOSURE TYPE: IP54 UNUSUAL CONDITIONS: DUST, FUMES, ETC. INSULATION CLASS F TEMP. RISE B
12 PLANT UTILITIES: ELECTRICITY 3 PHASE 50 CYCLE 400 VOLTS BAROMETER PRESSURE bara
13 REMARKS: (NOTE 4)
14 CRANE MOTION: ELECTRICITY AIR MANUAL SPEEDS POWER DUTY
15 HOIST VTS / VTS m/min VTS / VTS (KW) (%)
16 TROLLEY VTS / VTS m/min VTS / VTS (KW) (%)
17 BRIDGE VTS / VTS m/min VTS / VTS (KW) (%)
18 REMARKS: ELECTRICAL MOTORS SHALL BE DUAL SPEED TYPE.
19
20 CONTROL: TYPE (SPECIFY) PUSH BUTTONS FOR 2 SPEEDS (NOTE 6) TEST AND INSPECTION
21 CONTROL LOCATION: CAB FLOOR PENDANT STATION STATIC LOAD TEST (125% OF RATED LOAD)
22 OTHER AT MANUFACTURE’S SHOP
23 BRIDGE SHALL BE FURNISHED BY VENDOR YES NO AT SITE
24 TYPE REQUIRED: (TO BE SUPPLIED BY VENDOR) DYNAMIC LOAD TEST (110% OF SWL)
25 BRIDGE TROLLEY AT MANUFACTURE’S SHOP
26 RUNAWAY COLLECTORS AT SITE
27 RUNAWAY CONDUCTORS LIMIT SWITCHES FUNCTIONAL TEST
28 CABLE REEL LIFTING AND LOWERING
29 FESTOONED CABLE TROLLEY/BRIDGE TRAVEL
30 ITEMS TO BE SUPPLIED BY VENDOR: PACKING/MARKING AT DELIVERY POINT
31 RAIL SWEEP FOR BRIDGES RAIL SWEEP FOR TROLLEYS MATERIAL CERTIFICATES (NOTE 13)
32 BUMPER STOPS FOR BRIDGES BUMPER STOPS FOR TROLLEYS TYPE NDT OF WELDING (NOTE 14)
33 SURFACE PREPARATION YES NO OTHER LIQUID PENETRANT MAG. PARTICLE
34 PAINTING, PRIME PAINT REQUIRED FINISH PAINT REQUIRED RADIOGRAPHIC ULTRASONIC
35 FLOOD LIGHTS REQUIRED, TYPE SPARK RESISTANT CONSTRUCTION BRIDGE DEFLECTION (1/750 OF SPAN)
36 ELECTRIC SPACE HEATER REQUIRED BRAKES FOR HOIST, TROLLEY & BRIDGE SPEED TEST
37 SINGLE POINT LUBRICATION SYSTEM LIMIT SWITCHES (NOTE 5) FULL FUNCTIONAL TEST (WITHOUT LOAD)
38 MAINTENANCE & SERVICE PLATFORMS WARNING LAMP AND SIRENS
39 NAME PLATE FOR ALL COMPONENTS EARTH CONNECTION (NOTE 9)
40 SPARE PARTS FOR PRECOMMISSIONING, COMMISSIONING AND 2 YEARS OF OPERATION
41 INSTALLATION SUPERVISION SPECIAL TOOLS (IF APPLICABLE)
42 JUNCTION BOX, LOCAL PANELS, CABINETS, WIRING AND TERMINATION
43
44 REMARKS:
45
46
47
48
49
50
CONT. No.: 1187/EB-GN/DBS-BD01-00 REF. No.: 1187-DS-PM-41-03
1 NOTES
2
3 1) REFERENCE SPECIFICATION IS "PROJECT SPECIFICATION FOR OVERHEAD AND PORTAL BRIDGE (GANTRY) CRANES, DOC. NO. 1187-00-EB-GN-SP-9078.
4 2) ACCESS LADDER/WALKWAY TO BE PROVIDED (IF REQUIRED).
5 3) MAXIMUM ALLOWABLE SOUND LEVEL SHALL BE LIMITED TO 85 dbA.
6 4) GENERAL FUTURES OF MOTOR SHALL BE ACCORDING TO "PROJECT SPECIFICATION FOR ELECTRICAL LV INDUCTION MOTORS; DOC. NO. 1187-00-EB-EL-SP-6002".
7 5) LIMIT SWITCHES SHALL BE TOTALLY ENCLOSED, HEAVY DUST AND SPLASH PROOF TYPE.
8 6) PUSH BOTTON ENCLOSURE CONTROL FOR MAIN PUMPS SHELTER CRANE SHALL BE FLAME PROOF TYPE , CAST AL. ALLOY OR OTHER APPROVED
9 MATERIAL , WITH FLEXIBLE MULTICORE CABLE CONNECTION.
10 7) FOR FINALIZING CRANE DIMENSIONS AND SUPPLEMENTARY NOTES REFER TO "Basic Architectural Drawing For Workshop , Warehouse and Diesel Generator;
11 DWG. NO. 1187-41-EB-AR-DWG-BD4103-01".
12 8) SPEED TORQUE CURVE FOR HOIST SHALL BE SUBMITTED WITH QUOTATION.
13 9) CRANES AND ASSOCIATED METAL STRUCTURES AND EQUIPMENT SHALL BE SUITABLY CONNECTED TO THE MAIN EARTHING NETWORK OF THE PLANT.
14 THE CRANE WHEELS SHALL NOT BE USED AS MEANS OF EARTHING.
15 10) THE ELEVATION OF LOWEST HOOK POSITION WITH RESPECT TO GROUND LEVEL CONSIDERING WHOLE DIFFERENT REQUIREMENT (MAINTENANCE AND ETC.)
16 IS MAX. 1 M ABOVE GROUND LEVEL. VENDOR TO CONFIRM.
17 11) MAX. ALLOWABLE HEIGHT OF CRANE BRIDGE AND ITS AUXILIARIES (RAIL, END CARRIAGE AND CONTROL PANEL) SHALL NOT EXCEED 600 MM
18 BECAUSE OF LIGHTING. VENDOR TO CONFIRM.
19 12) HOIST SHALL BE WIRE ROPE TYPE.
20 13) MATERIAL CERTIFICATE SHALL BE ACCORDING TO LATEST EDITION OF EN 10204 (TYPE 3.1).
21 14) NDT SHALL BE PERFORMED AS PER ASME SEC. V.
22 15) ALL VENDORS AND MANUFACTURERS SHALL BE SELECTED FROM NIOEC AVL.
23 16) THE TYPE OF HOOK SHALL BE SWIVEL TYPE CAPABLE OF FREE ROTATING (HOOK BLOCK) EQUIPPED WITH SPRING SAFETY LATCH.
24 17) DRAWING SHOWING OVERALL DIMENSIONS & CLEARANCES SHALL BE SUBMITTED WITH QUOTATION.