You are on page 1of 6

PROJECT TITLE :

EPCC USM METERING STATION AT SIMPANG ABADI


JAMBI

CLIENT :

PT. ADIPROTEK ENVIRODUNIA


PT. PDPDE GAS

DOCUMENT TITLE :

DATA SHEET FOR Y-TYPE STRAINER (FIRE WATER)

DOCUMENT STATUS
Approved
:

Approved
: as Noted

Not Approved

A1 FEBRUARY 07, 2011 ISSUED FOR INTERNAL REVIEW ME ES JPM SA


ENG EM PM
REV. DATE DESCRIPTION PREPARED
CHECKED APPROVED

TOTAL OR PARTIAL REPRODUCTION AND / OR UTILIZATION OF THIS DOCUMENT ARE FORBIDDEN


WITHOUT PRIOR WRITTEN AUTHORIZATION OF THE OWNER

CLIENT : CLIENT CONTRACT NO. : CONTRACTOR :


CONTRACTOR JOB NO. : C - 207 / 2010

CONTRACTOR DOCUMENT NO. : 21 - 207 - L - DS - 110


CLIENT DOCUMENT NO. : -
PT. ADIPROTEK ENVIRODUNIA SHEET NO. : 1 OF 4 PT. ISTANA KARANG LAUT
PT. PDPDE GAS

603314972.xls
CLIENT : CONTRACTOR :
EPCC USM METERING STATION AT SIMPANG ABADI
JAMBI

PT. ADIPROTEK ENVIRODUNIA


PT. ADIPROTEK ENVIRODUNIA
PT. PDPDE GAS PT. ISTANA KARANG LAUT
PT. PDPDE GAS

TABULATION OF REVISED PAGES


REVISIONS REVISIONS
SHEET SHEET
A1
1 X 51
2 X 52
3 X 53
4 X 54
5 55
6 56
7 57
8 58
9 59
10 60
11 61
12 62
13 63
14 64
15 65
16 66
17 67
18 68
19 69
20 70
21 71
22 72
23 73
24 74
25 75
26 76
27 77
28 78
29 79
30 80
31 81
32 82
33 83
34 84
35 85
36 86
37 87
38 88
39 89
40 90
41 91
42 92
43 93
44 94
45 95
46 96
47 97
48 98
49 99
50 100
Client Document Number : Contractor Document Number : Sheet Number :
21 - 207 - L - DS - 110 2 OF 4
603314972.xls
CLIENT : CONTRACTOR :

Document No. Contract No. : -


DATA SHEET FOR STRAINER Rev.

BUCKET STRAINER

TAG KETERANGAN
1 Vent assembly
2 O-Ring
3 Quick open eye bolts
4 Cover plate
5 Ring flange

6 Outlet nozzle

7 Body assembly
8 Basket
9 Drain assembly

DESIGN
SIZE : 6''
RATING : 150
END CONNECTION : RF FLANGED END AS PER ASME B16.5
VENT CONNECTION : 3/4" C/W THREADED PLUG
DRAIN CONNECTION : 3/4" C/W THREADED CONNECTION
MESH SIZE : TBA
SERVICE : CPO

MATERIAL

BODY / COVER : DUCTILE IRON

SCREEN : TBA
GASKET : SPWD 316 SS WINDING AND GRAPHITE FILLER
BOLTS & NUT'S : A 193 GR B7 + HDG
PLUG : ASTM A 105

INSPECTION AND TESTING


VISUAL EXAMINATION : 100% AS PER MSS-SP-55
LIQUID PENETRANT EXAM. : API 598 / ASME 16.34
HYDROSTEST PRESSURE : YES (1.5 x DESIGN PRESSURE)

CERTIFICATION : BS EN 10204 TYPE 3.1


PAINTING : MANUFACTURER STANDARD

NOTE

1. NAME PLATE FLAME ARRESTER HARUS TERBUAT DARI MATERIAL STAINLESS STEEL
2. 100% LIQUID PENETRANT TEST
3. VENDOR ATAU SUPPLIER HARUS CONFIRM UNTUK PRESSURE DROP TIDAK MELEBIH1 DARI 2 PSIG
4. SCREEN ATAU STRAINER MUDAH UNTUK DI LEPAS DAN DI GANTI DENGAN YANG BARU

603314972.xls
603314972.xls
CLIENT : CONTRACTOR :

EPCC USM METERING STATION AT SIMPANG ABADI


JAMBI

PT. ADIPROTEK ENVIRODUNIA PT. ISTANA KARANG LAUT


PT. PDPDE GAS

Document No. Contract No. : C-207/10


DATA SHEET FOR Y-TYPE STRAINER (FIRE WATER) Page Rev.
21-207-L-DS-110
4 of 4 A1

NO. TAG NO. END CONNECTION P & ID NO. LINE NO. Remark

1 3"-21-SP-110 RF x RF 21-207-P-PID-009 3"-21-FW-A1W-101

2 3"-21-SP-111 RF x RF 21-207-P-PID-009 3"-21-FW-A1W-102

3 1"-21-SP-112 RF x RF 21-207-P-PID-009 1"-21-FW-A1W-103

603314972.xls
603314972.xls