You are on page 1of 1

Wiring diagram ekey dLine

ID355/741/0/710: Version 1, 2020-10-02

Connection to the motorized lock


Pin Color Description

- green Switching impulse (+)


See connection con guration
of the motorized lock - brown GND (-) DANGER
manufacturer Risk of electrocution: All ekey devices
- white VDC (+) are to be operated with Safety Extra
Low Voltage (SELV). Only use power
1 supplies rated protection class 2 with
safety approval according to
EN 62368-1.
Failure to do so will create a risk of
Connection to the control unit fatal electrocution.
Only certi ed electricians are
authorized to carry out electrical
Pin Color Description installation work on mains systems.

4 - - ATTENTION

1 2 3 4
Property damage in the event of
3 green Switching impulse (+) incorrect mounting and wiring: The
system devices are operated using
2 brown GND (-) electricity.
They could be destroyed if they are
1 white VDC (+) mounted and wired incorrectly.
Mount and wire the system devices
3 correctly before connecting the
power.

Connection to the electrical installation NOTICE


This wiring diagram is not subject to
Color Description updating. We reserve the right to make
technical modi cations and change the
white VDC (+) (12-24) product‘s appearance; any liability for
M errors and misprints is excluded.
brown GND (-)
1 ekey dLine ngerprint
green ekey bus 450 007
5
yellow ekey bus 2 ekey dLine cable FP
Potential-free
blue Input request-to-exit 3 ekey dLine controller
button for manual 450 008
gray Input door opening 4 ekey dLine cable MT
pink For testing purposes 5 ekey dLine cable transfer
48 cm 2,5 m
red For testing purposes 201 401
2
4 Each unused core must be insulated separately!