Professional Documents
Culture Documents
ELEMENTARY SECTION
1. E/S No.21202 on DN line i) Movement of Electric Trains/Locos shall NIL i) Open BM-212 at i) Close SM-194 at Loc.
between section RGL - not be permitted into section RGL - LPG RGL/TSS. No. 530/38.
LPG. on DN line. ii) Open SM-194 at Loc. ii) Close BM-212 at
Location from RGL/TSS to ii) Line clear shall not be granted to RGL No. 530/38. RGL/TSS.
SM-194 at Loc. No. for Electric Trains/Locos on DN line.
530/38. iii) DN reception signal shall be kept at
‘ON’.
2 E/S No.21204 on DN line i) Movement of Electric Trains/Locos shall Crossover i) Ensure SS/234 of LPG at Loc.No. 530/8A is in open
between section RGL - not be permitted into section RGL - LPG point position.
LPG. on DN line. No.52A/B,60A/ i) Open SM-194 at Loc. i) Close SM/196 of LPG
Location from SM-194 at ii) Line clear shall not be granted to RGL B, 64A/B and No. 530/38. at Loc. No. 529/34.
Loc. No. 530/38 to SM-196 for Electric Trains/Locos on DN line. 88A/B at RGL ii) Open SM/196 of LPG ii) Close SM-194 at Loc.
at Loc. No. 529/34. iii) Electric Trains/Locos can be admitted end shall be at Loc. No. 529/34. No. 530/38.
into Common Loop Line (L/1, L/2 & L/3) kept at normal
from BPSL & AIPL siding. position only.
iv) Shunting of Electric Trains/Locos shall
be prohibited from L-3 to L-4 at RGL
end.
v) DN reception signal shall be kept at
‘ON’.
vi) UP trains can be admitted on L-1, L-2 &
L-3.
3. E/S No.21206 on DN Main i) Movement of Electric Trains/Locos shall Crossover i) Open BM-214 at i) Close SM-196 of LPG
line at LPG. Location from not be permitted into DN Main line (L/4) point LPG/SSP. at Loc. No.529/34.
SM-196 of LPG at Loc. at LPG. No.85A/B, ii) Open SM-196 of LPG ii) Close BM-214 at
No.529/34 to LPG/SSP. ii) DN Electric Trains/Locos from RGL can 79A/B & 57A/B at Loc. No.529/34. LPG/SSP.
be admitted into Common Loop line at BXQ end
(L/1, L/2 & L/3) but cannot be shall be kept at
dispatched towards BXQ on DN line. normal position
iii) DN Electric Trains/Locos admitted at only.
Common Loop Line (L/6, L/7 & L/8) can
be dispatched towards BXQ on DN line.
iv) UP Electric Trains/Locos from BXQ
cannot be admitted into Common Loop
Line (L/1, L/2 & L/3).
v) Ensure that no Electric Trains/Locos is
standing with its panto raised condition
on DN Main line (L/4).
vi) DN reception and dispatch signals for
DN Main Line shall be kept at ‘ON’.
9. E/S No.X-235 on i) Movement of Electric Trains/Locos shall Crossover i) Ensure SS-239 of LPG at Loc. No. 528/47A is
Common Loop line (L/6) not be permitted into Common Loop point No. in open position.
including Common Loop line (L/6) including Common Loop Line 80A/B, 86A/B ii) Ensure SS-231 of LPG at Loc. No. LPG/1145 is
Line No. (L/7 & L/8) at No. (L/7 & L/8) at LPG. at RGL end in open position.
LPG. ii) Electric Trains/Locos cannot be and point i) Open SS-235 of i) Close SS-235 of
(E/S No. X- 237,X-233 admitted/dispatched to/from Common No.95A/B, LPG at Loc. No. LPG at Loc. No.
get automatically Loop line (L/6) including Common Loop 89A/B & 69A/B 529/7. 529/7.
blocked) Line No. (L/7 & L/8) at LPG on both the at BXQ end
directions. shall be kept
iii) Ensure that no Electric Trains/Locos is at normal
standing with its panto raised condition position only.
on Common Loop line (L/6) including
Common Loop Line No. (L/7 & L/8) at
LPG.
iv) Reception & dispatch signals for
Common Loop line (L/6) including
Common Loop Line No. (L/7 & L/8) at
LPG shall be kept at ‘ON’.
10. E/S No. X-237 on i) Movement of Electric Trains/Locos shall NIL i) Open SS-237 of i) Close SS-237A of
Common Loop Line (L/7) not be permitted into Common Loop LPG at Loc. No. LPG at Loc.
at LPG. Line (L/7) at LPG. LPG/1107A first. No.529/11A first.
ii) No Electric Trains/Locos can be ii) Then open SS- ii) Then close SS-237
admitted/dispatched into/from Common 237A of LPG at of LPG at Loc. No.
Loop Line (L/7) from/towards both the Loc. No.529/11A. LPG/1107A.
directions.
iii) Ensure that no Electric Loco is standing
with its panto raised condition on
Common Loop Line (L/7).
iv) Loading work can be performed on
Common Loop Line (L/7) only after
elementary section made dead.
v) Reception & dispatch signals for
Common Loop Line (L/7) at both ends
shall be kept at ‘ON’.
NOTE:
i) For any unusual movement of Electric Locos, the Station Master on duty must refer to the working rule diagram from 25KV AC traction of his
station and ensured that there is no chance of energizing the section where power block has been granted.
ii) Points leading to unwired tracks shall not be used for the movement of Electric Loco with pantograph raised.
iii) Refer drawing No. TRD/SBP/LPG/SWR/MOD-05.