Hammer Circuit Test Date:

By:
Instructions
Sequence Table Action required
1 A Record machine data in Table A
2 B Insert hammer flow specifications in Table B
3 Adjust PRV setting with flow meter
4 C Record flow meter at pressures listed in table in Table C.
5 D Record back pressure and relief pressures in table D
6 E Record operating pressure while hammer is running in Table E.
7 E Click on blue line and position on graph to crack point value measure in Table D.
8 E Click on red dash line and move to chart equal to operating pressure measured in Table D.
9 F Complete questionnaire in Table E

Table A:
Date: 23May03
Carrier: 345B PIN 4SS000788 SMU 4390 Correct setting:
Hammer H180s PIN 9PM00577 SMU 0
When flow curve intersects operating pressure
line within the allowable flow range of the hammer
Table B:
Hammer MIN - MAX
Flow spec 58 - 80

Table C: Pressure-Flow
Data D: Curve
Pressure Flow
psi gpm
1000 90
1200 85 100
1400 85
1600 85
1800 84
80 Maximum gpm = 88
Flow (gpm)

2000 84 H18Cs Flow Range


2200 83 60
2400 83 Minimum gpm = 68
2600 80
2800 72 40
3000 56
3200 0
3400 20
3600
3800
0
1000 1500 2000 2500 3000 3500 4000
Table D;
Back pressure 100 Pressure (psi)
Relief crack point 2800
Relief full setting 3200
Blue line = crack point
Red dash line represents operating pressure
Table E:

Hammer 2250 psi


Operating psi US Oil Flow Metric Oil Flow
Pressure Pressure
Min Max Min Max
Models psi gpm gpm Model kPa gpm gpm
H100 2130 16 32 H100 14690 60 121
H115s 2030 18 34 H115s 14000 68 129
H120Cs 2030 26 42 H120Cs 14000 98 159
H130s 2030 32 58 H130s 14000 120 220
H140Ds 2321 42 60 H140Ds 16007 158 227
H160Ds 2321 58 82 H160Ds 16007 218 310
H180D s 2321 68 88 H180D s 16007 255 333
(4) Supply line from main control valve to attachmen
Table F: (18) Flow meter
1 What is the safety margin between operating pressure and crack point of relief valve? (22) Return line to oil cooler.
a. 800 psi (23) Multitach
(24) Flow meter valve
2 Back pressure acceptable for hammer operation?
a. YES maximum allowable is 145 psi - measured 100 psi

3 What is the flow range of the hammer?


a. 58 to 80 gpm

4 Flow correct at hammer operating specification?


a. YES 80gpm @ 2000 ps

You might also like