You are on page 1of 94

DEKRA Certification, Inc.

405 Glenn Dr. Suite 12,


Sterling, VA 20164
United States of America

Test report No:


2498ERM.005A1

Test report
ETSI EN 300 328 v 2.1.1 (2016-11): Wideband transmission
systems; Data transmission equipment operating in the 2,4 GHz
ISM band and using wide band modulation techniques;
Harmonised Standard covering the essential requirements of
article 3.2 of Directive 2014/53/EU

Identification of item tested Table top 3D printer

Trademark Ultimaker

Model and /or type reference S3

Other identification of the product --

Features LAN, Wi-Fi, NFC, Camera

Manufacturer ULTIMAKER BV
Stationsplein 32 3511ED UTRECHT

Test method requested, standard ETSI EN 300 328 v2.1.1 (2016-11): Wideband
transmission systems; Data transmission equipment
operating in the 2,4 GHz ISM band and using wide band
modulation techniques
Summary IN COMPLIANCE

Approved by (name / position & Domingo Galvez


signature) EMC&RF Lab Manager

Date of issue 09-30-2019

Report template No FDT08_21

Report No: 2498ERM.005A1 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Index
Competences and guarantees .................................................................................................... 3
General conditions ...................................................................................................................... 3
Uncertainty ................................................................................................................................. 3
Data provided by the client.......................................................................................................... 4
Usage of samples ....................................................................................................................... 4
Test sample description .............................................................................................................. 5
Identification of the client............................................................................................................. 6
Testing period and place ............................................................................................................. 6
Document history ........................................................................................................................ 6
Modifications to the reference test report .................................................................................... 7
Environmental conditions ............................................................................................................ 7
Remarks and comments ............................................................................................................. 8
Testing verdicts........................................................................................................................... 9
Summary .................................................................................................................................... 9
List of Equipment’s.................................................................................................................... 10
Appendix A: .............................................................................................................................. 11
Appendix B: Test results ........................................................................................................... 18
Appendix C: Photographs ......................................................................................................... 92

Report No: 2498ERM.005A1 Page 2 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Competences and guarantees


DEKRA Certification Inc. is a testing laboratory accredited by A2LA (The American Association for Laboratory
Accreditation), to perform the tests indicated in the Certificate 2764.01
DEKRA Certification Inc. is a testing laboratory competent to carry out the tests described in this report.
In order to assure the traceability to other national and international laboratories, DEKRA Certification Inc. has a
calibration and maintenance program for its measurement equipment.
DEKRA Certification Inc. guarantees the reliability of the data presented in this report, which is the result of the
measurements and the tests performed to the item under test on the date and under the conditions stated on
the report and, it is based on the knowledge and technical facilities available at DEKRA Certification at the time
of performance of the test.
DEKRA Certification Inc. is liable to the client for the maintenance of the confidentiality of all information related
to the item under test and the results of the test.
The results presented in this Test Report apply only to the particular item under test established in this
document.
IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
except in full, without the previous written permission of DEKRA Certification Inc.

General conditions
1. This report is only referred to the item that has undergone the test.
2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
or competent Authorities.
3. This document is only valid if complete; no partial reproduction can be made without previous written
permission of DEKRA Certification Inc.
4. This test report cannot be used partially or in full for publicity and/or promotional purposes without
previous written permission of DEKRA Certification Inc. and the Accreditation Bodies.

Uncertainty
Uncertainty (factor k=2) was calculated according to the DEKRA Certification internal document PODT000.

Frequency (MHz) U(k=2) Units


30-180 3.82 dB
180-1000 2.61 dB
1000-18000 2.92 dB
18000-40000 2.15 dB

Report No: 2498ERM.005A1 Page 3 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Data provided by the client


Table top 3D printer according to FFF principle. Capable of printing several engineering thermal plastics.
Connectivity through: LAN, Wi-Fi, communication with spool by RF-ID/ NFC, Camera deployed
DEKRA declines any responsibility with respect to the information provided by the client and that may affect the
validity of results.

Usage of samples
Samples undergoing test have been selected by: The client.
Sample S/01 is composed of the following elements:

Date of
Control Nº Description Model Serial Nº
reception
2498/01 S3 3D Printer Body S3 S3-R1-00 06/26/2019

1. Sample S/01 has undergone following test(s):


All conducted tests indicated in appendix A & B.
Sample S/02 is composed of the following elements:

Date of
Control Nº Description Model Serial Nº
reception
2498/01 S3 3D Printer Body S3 S3-R1-00 06/26/2019

1. Sample S/02 has undergone following test(s):


All radiated tests indicated in appendix A & B.Sample S/01 & S/02 is composed of the following accessories:

Date of
Control Nº Description Model Serial Nº
reception
2498/02 Fan IndustrialPPC --- 06/26/2019

2498/03 Hood Bed (plastic) --- --- 06/26/2019

2498/04 Hood (Clear Plastic) --- --- 06/26/2019

2498/05 Plywood Frame --- --- 06/26/2019

2498/06 Filter --- --- 06/26/2019

2498/07 Fan Power Connector --- --- 06/26/2019

2497/02 Reel 01612 --- 06/27/2019

Report No: 2498ERM.005A1 Page 4 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Test sample description


Ports……………………………….: Cable
Port name and description
Specified Attached Shielded
length [m] during test

LAN >3

USB <3

Supplementary information to the Not provided data


ports………………………………. :
Rated power supply .................... : Reference poles
Voltage and Frequency
L1 L2 L3 N PE

AC: 230Vac / 50Hz.

AC:

DC:

DC:

Rated Power ............................... : "90-264 Vac 47 ~ 63 Hz, 4,85 A O/P 24 Vdc, 21 A, 500 W max."

Clock frequencies ....................... : Data Not Provided

Other parameters ........................ : Data Not Provided

Software version ......................... : 5.2.5

Hardware version ........................ : UMS5R2

Dimensions in cm (L x W x D) .... : Data Not Provided

Mounting position ........................ : Table top equipment


Wall/Ceiling mounted equipment
Floor standing equipment
Hand-held equipment
Other:
Modules/parts ............................. : Module/parts of test item Type Manufacturer

3D-Printer S3 UM
Air Manager Air Manager UM
Accessories (not part of the test Description Type Manufacturer
item) ............................................ :
Data Not Provided

Report No: 2498ERM.005A1 Page 5 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Documents as provided by the Description File name Issue date


applicant ...................................... :
Equipment declaration Data FDT30_14 -
Declaration
Equipment Data_NA

Copy of marking plate:

Identification of the client


ULTIMAKER BV
STATIONSPLEIN 32 3511ED UTRECHT

Testing period and place


Test Location DEKRA Certification Inc.
Date (start) 08-14-2019
Date (finish) 08-22-2019

Document history

Report number Date Description


2498ERM.005 09-03-2019 First release
2498ERM.005A1 09-30-2019 Second release

Report No: 2498ERM.005A1 Page 6 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Modifications to the reference test report


It was introduced the following modification in respect to the test report number 2498ERM.005 related with
the same samples:

Clauses/ Sub-Clauses Modification Justification

Declaration letter was


Page 8 / Remarks and comments Client Request
included

This modification test report cancels and replaces the test report 2498ERM.005.

Environmental conditions

In the control chamber, the following limits were not exceeded during the test:

Min. = 15 ºC
Temperature
Max. = 35 ºC
Min. = 30 %
Relative humidity
Max. = 75 %
Min. = 860 mbar
Air pressure
Max. = 1060 mbar

In the semi anechoic chamber, the following limits were not exceeded during the test.

Min. = 15 ºC
Temperature
Max. = 35 ºC
Min. = 30 %
Relative humidity
Max. = 75 %
Min. = 860 mbar
Air pressure
Max. = 1060 mbar

In the chamber for conducted measurements, the following limits were not exceeded during the test:
Temperature Min. = 15 ºC
Max. = 35 ºC
Relative humidity Min. = 30 %
Max. = 60 %
Air pressure Min. = 860 mbar
Max. = 1060 mbar

Report No: 2498ERM.005A1 Page 7 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Remarks and comments


1. The tests have been performed by the technical personnel: Divya Adusumilli, Koji Nishimoto and Poojita
Bhattu.
2. Applicant’s declaration letter shown below.

Report No: 2498ERM.005A1 Page 8 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Testing verdicts

Not applicable : N/A

Pass : P

Fail : F

Not measured : N/M

Summary

EN 300 328 PARAGRAPH


Requirement – Test case Verdict Remark
4.3.2.2 Transmitter. RF Output Power P N/A
4.3.2.3 Transmitter. Power Spectral Density P N/A
4.3.2.4 Transmitter. Duty cycle, Tx-Sequence, Tx-gap N/A Refer 1
4.3.1.4 Accumulated Transmit Time, Frequency Occupation & Hopping Refer 1
N/A
Sequence
4.3.1.5 Hopping Frequency Separation N/A Refer 1
4.3.2.5 Medium Utilization N/A Refer 1
4.3.2.6 Adaptivity P N/A
4.3.2.7 Occupied Channel Bandwidth P N/A
4.3.2.8 Transmitter unwanted emissions in the out-of-band domain P N/A
4.3.2.9 Transmitter unwanted emissions in the spurious domain (conducted) N/A Refer 3
4.3.2.9 Transmitter unwanted emissions in the spurious domain (radiated) P N/A
4.3.2.10 Receiver spurious emissions (conducted) N/A Refer 3
4.3.2.10 Receiver spurious emissions (radiated) P N/A
4.3.2.11 Receiver blocking P N/A
4.3.2.12 Geo-location capability N/A Refer 2
Supplementary information and remarks:
1. The equipment is declared as non-adaptive equipment, using other forms of modulation than FHSS.
The maximum measured RF Output power level is less than 10 dBm e.i.r.p.
2. The equipment does not implement geo-location capability as defined in clause 4.3.2.12.2.
3. The equipment is incorporated with Integral antenna.

Report No: 2498ERM.005A1 Page 9 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

List of Equipment’s

Conducted Measurements

Test system Rohde & Schwarz TS 8997:

CONTROL LAST NEXT


DESCRIPTION
NUMBER CALIBRATION CALIBRATION
1039 Signal analyzer Rohde & Schwarz FSV40 2018/10 2020/03

Switch unit Rohde & Schwarz with power


1040 2017/03 2020/03
detector OSP120 / OSP-B157

1041 RF generator Rohde & Schwarz SMB100A 2017/04 2020/04

1042 RF generator Rohde & Schwarz SMBV100A 2018/01 2020/01

0101 Climatic chamber Espec 2019/01 2020/01

Radiated Measurements

CONTROL LAST NEXT


DESCRIPTION MANUFACTURER MODEL
NUMBER CALIBRATION CALIBRATION
1012 EMI Test Receiver ROHDE & ESR26 2018/09 2020/09
SCHWARZ
1014 Signal Analyzer ROHDE & FSV40 2019/04 2021/04
SCHWARZ
1058 Double Ridged ETS LINDGREN 3115 2017/03 2020/03
Waveguide Horn Antenna
1064 Biconilog Antenna ETS LINDGREN 3142E 2017/03 2020/03
BONN BLMA 0118-
0981 Preamplifier 2018/10 2020/10
ELEKTRONIK 2A
EMC measurement ROHDE & EMC32
1017 --- ---
software SCHWARZ V9.01
0880 High Pass Filter ETS LINDGREN EMCenter -- --
Ethernet SNMP
HWg-STE
1110 Thermometer – MR HW GROUP 2017/09 2019/09
Plain
Room
Ethernet SNMP HWg-STE
1108 HW GROUP 2017/09 2019/09
Thermometer – CR Room Plain
Ethernet SNMP HWg-STE
1111 HW GROUP 2017/09 2019/09
Thermometer – SAC Plain

Report No: 2498ERM.005A1 Page 10 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Appendix A:
Application form for testing

Report No: 2498ERM.005A1 Page 11 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Information to declare according to ETSI EN 300 328


In accordance with EN 300 328, clause 5.4.1, the following information is provided by the manufacturer.

a) The type of modulation used by the equipment:

FHSS

other forms of modulation

b) In case of FHSS modulation:

 In case of non-Adaptive Frequency Hopping equipment:

The number of Hopping Frequencies: ……N/A……..

 In case of Adaptive Frequency Hopping Equipment:

The maximum number of Hopping Frequencies: …N/A………..

The minimum number of Hopping Frequencies: ……N/A……..

 The (average) Dwell Time: …N/A………..

c) Adaptive / non-adaptive equipment:

non-adaptive Equipment

adaptive Equipment without the possibility to switch to a non-adaptive mode

adaptive Equipment which can also operate in a non-adaptive mode

d) In case of adaptive equipment:

The maximum Channel Occupancy Time implemented by the equipment: ...<13...... ms

The equipment has implemented an LBT based DAA mechanism

 In case of equipment using modulation different from FHSS:

The equipment is Frame Based equipment

The equipment is Load Based equipment

The equipment can switch dynamically between Frame Based and Load Based equipment

The CCA time implemented by the equipment: ........ µs

The equipment has implemented a non-LBT based DAA mechanism

The equipment can operate in more than one adaptive mode

The equipment has implemented Short Control Signalling Transmissions

e) In case of non-adaptive Equipment:

The maximum RF Output Power: ………. dBm

The maximum RF Output Power (e.i.r.p.): ………. dBm

The maximum (corresponding) Duty Cycle: ………. %


Report No: 2498ERM.005A1 Page 12 of 94 09-30-2019
DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Equipment with dynamic behaviour, that behaviour is described here. (e.g. the different combinations of duty cycle and
corresponding power levels to be declared):

......................................................................................................................................................

f) The worst case operational mode for each of the following tests:

 RF Output Power

... 802.11b / 802.11g / 802.11n(HT20) / 802.11n(HT40)................

 Power Spectral Density

..... 802.11b / 802.11g / 802.11n(HT20) / 802.11n(HT40)..............

 Duty cycle, Tx-Sequence, Tx-gap

.........................N/A................................................................

 Accumulated Transmit time, Frequency Occupation & Hopping Sequence (only for FHSS equipment)

...................N/A......................................................................

 Hopping Frequency Separation (only for FHSS equipment)

..................N/A.......................................................................

 Medium Utilization

.................N/A........................................................................

 Adaptivity & Receiver Blocking

........... 802.11b / 802.11g / 802.11n(HT20) / 802.11n(HT40).........................

 Nominal Channel Bandwidth

............. 802.11b / 802.11g / 802.11n(HT20) / 802.11n(HT40)....................

 Transmitter unwanted emissions in the OOB domain

............ 802.11b / 802.11g / 802.11n(HT20) / 802.11n(HT40).................

 Transmitter unwanted emissions in the spurious domain

..................... 802.11n(HT20)...........................

 Receiver spurious emissions

............... 802.11b.......................................

g) The different transmit operating modes (tick all that apply):

Operating mode 1: Single Antenna Equipment

Equipment with only one antenna

Equipment with two diversity antennas but only one antenna active at any moment in time

Report No: 2498ERM.005A1 Page 13 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Smart Antenna Systems with two or more antennas, but operating in a (legacy) mode where only one antenna
is used. (e.g. IEEE 802.11™ [i.3] legacy mode in smart antenna systems)

Operating mode 2: Smart Antenna Systems - Multiple Antennas without beam forming

Single spatial stream / Standard throughput / (e.g. IEEE 802.11™[i.3] legacy mode)

High Throughput (> 1 spatial stream) using Nominal Channel Bandwidth 1

High Throughput (> 1 spatial stream) using Nominal Channel Bandwidth 2

NOTE: Add more lines if more channel bandwidths are supported.

Operating mode 3: Smart Antenna Systems - Multiple Antennas with beam forming

Single spatial stream / Standard throughput (e.g. IEEE 802.11™ [i.3] legacy mode)

High Throughput (> 1 spatial stream) using Nominal Channel Bandwidth 1

High Throughput (> 1 spatial stream) using Nominal Channel Bandwidth 2

NOTE: Add more lines if more channel bandwidths are supported.

h) In case of Smart Antenna Systems:

 The number of Receive chains: .....2rx......

 The number of Transmit chains: ...2tx........

symmetrical power distribution

asymmetrical power distribution

In case of beam forming, the maximum (additional) beam forming gain: .....N/A...... dB

NOTE: The additional beam forming gain does not include the basic gain of a single antenna.

i) Operating Frequency Range(s) of the equipment:

 Operating Frequency Range 1: ...2412.. MHz to ..2472... MHz

 Operating Frequency Range 2: ........... MHz to ........... MHz

NOTE: Add more lines if more Frequency Ranges are supported.

j) Nominal Channel Bandwidth(s):

 Nominal Channel Bandwidth 1: ...20.. MHz

 Nominal Channel Bandwidth 2: ...40.... MHz

NOTE: Add more lines if more channel bandwidths are supported.

k) Type of Equipment (stand-alone, combined, plug-in radio device, etc.):

Stand-alone

Combined Equipment (Equipment where the radio part is fully integrated within another type of equipment)

Plug-in radio device (Equipment intended for a variety of host systems)

Other ..................................................................................

Report No: 2498ERM.005A1 Page 14 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

l) The normal and the extreme operating conditions that apply to the equipment:

Normal operating conditions (if applicable):

Operating temperature: …… ° C

Other (please specify if applicable): …… ° C

Extreme operating conditions:

Operating temperature range: Minimum …… ° C Maximum ……° C

Other (please specify if applicable): Minimum …… ° C Maximum ……° C

Details provided are for the: stand-alone equipment

combined (or host) equipment

test jig

m) The intended combination(s) of the radio equipment power settings and one or more antenna assemblies and their
corresponding e.i.r.p levels:

 Antenna Type:

Integral Antenna

Antenna Gain: ............. dBi

If applicable, additional beamforming gain (excluding basic antenna gain): ............. dB

Temporary RF connector provided

No temporary RF connector provided

Dedicated Antennas (equipment with antenna connector)

Single power level with corresponding antenna(s)

Multiple power settings and corresponding antenna(s)

Number of different Power Levels: .............

Power Level 1: ............. dBm

Power Level 2: ............. dBm

NOTE 1: Add more lines in case the equipment has more power levels.

NOTE 2: These power levels are conducted power levels (at antenna connector).

 For each of the Power Levels, provide the intended antenna assemblies, their corresponding gains (G) and the
resulting e.i.r.p. levels also taking into account the beamforming gain (Y) if applicable

Power Level 1: ....16.3.... dBm

Number of antenna assemblies provided for this power level: ...1......

Report No: 2498ERM.005A1 Page 15 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

e.i.r.p.
Assembly # Gain (dBi) Part number or model name
(dBm)
1 2.8 19.92 NA
2
3
4

NOTE 3: Add more rows in case more antenna assemblies are supported for this power level.

Power Level 2: ............. dBm

Number of antenna assemblies provided for this power level: .........

e.i.r.p.
Assembly # Gain (dBi) Part number or model name
(dBm)
1
2
3
4

NOTE 4: Add more rows in case more antenna assemblies are supported for this power level.

Power Level 3: ............. dBm

Number of antenna assemblies provided for this power level: .........

e.i.r.p.
Assembly # Gain (dBi) Part number or model name
(dBm)
1
2
3
4

NOTE 5: Add more rows in case more antenna assemblies are supported for this power level.

n) The nominal voltages of the stand-alone radio equipment or the nominal voltages of the combined (host) equipment
or test jig in case of plug-in devices:

Details provided are for the: stand-alone equipment

combined (or host) equipment

test jig

Supply Voltage AC mains State AC voltage ……….. V

DC State DC voltage ……3.3….. V

In case of DC, indicate the type of power source

Internal Power Supply

External Power Supply or AC/DC adapter

Battery

Other: ...................

Report No: 2498ERM.005A1 Page 16 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

o) Describe the test modes available which can facilitate testing:

..... Controlling software (72-Y5313-1_QRCT_CONN) has been activated to set the EUT on specific channel and power
level
.....................................

................................................................................................................................................ ......

p) The equipment type (e.g. Bluetooth®, IEEE 802.11™[i.3], IEEE 802.15.4™[i.4], proprietary, etc.):

....................... IEEE 802.11TM [i.3].........................................


q) If applicable, the statistical analysis referred to in clause 5.4.1 q)

(to be provided as separate attachment)

r) If applicable, the statistical analysis referred to in clause 5.4.1 r)

(to be provided as separate attachment)

s) Geo-location capability supported by the equipment:

Yes
The geographical location determined by the equipment as defined in clause 4.3.1.13.2 or clause 4.3.2.12.2 is not
accessible to the user.
No

t) Describe the minimum performance criteria that apply to the equipment (see clause 4.3.1.12.3 or clause 4.3.2.11.3):

......................................................................................................................................................

......................................................................................................................................................

......................................................................................................................................................

Report No: 2498ERM.005A1 Page 17 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Appendix B: Test results


(Wi-Fi 2.4 GHz b/g/n20/n40 modes)

Report No: 2498ERM.005A1 Page 18 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Appendix B Content
PRODUCT INFORMATION ...................................................................................................... 20
DESCRIPTION OF TEST CONDITIONS .................................................................................. 21
TEST 4.3.2.2: TRANSMITTER. RF OUTPUT POWER. ............................................................ 22
TEST 4.3.2.3: TRANSMITTER. POWER SPECTRAL DENSITY. ............................................. 25
TEST 4.3.2.6: ADAPTIVITY ...................................................................................................... 34
TEST 4.3.2.7: OCCUPIED CHANNEL BANDWIDTH. ............................................................... 39
TEST 4.3.2.8: TRANSMITTER UNWANTED EMISSIONS IN THE OUT-OF-BAND (OOB)
DOMAIN. .................................................................................................................................. 48
TEST 4.3.2.9: TRANSMITTER UNWANTED EMISSIONS IN THE SPURIOUS DOMAIN
(RADIATED) ............................................................................................................................. 61
TEST 4.3.2.10: RECEIVER SPURIOUS EMISSIONS (RADIATED) ......................................... 79
TEST 4.3.2.11: RECEIVER BLOCKING ................................................................................... 89

Report No: 2498ERM.005A1 Page 19 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

PRODUCT INFORMATION

The following information is provided by the supplier, in accordance with clause 5.4.1:

Information Description

Modulation DSSS/OFDM

Adaptive Adaptive Equipment without the possibility to


switch to a Non-adaptive mode.

Operation mode 1: Single Antenna Equipment Equipment with only one antenna

- Operating Frequency Range 2412 – 2472 MHz

- Nominal Channel Bandwidth 802.11b / 802.11g / 802.11n(HT20) /


802.11n(HT40)

- RF Output Power b mode = 18 dBm @ 11 Mbps

g mode = 16 dBm @ 54 Mbps

n mode = 16 dBm @ MCS7

Extreme operating conditions

- Temperature range -40 ºC to +70 ºC

Antenna type Dedicated Antenna

Antenna gain +2.8 dBi

Nominal Voltage

- Supply Voltage 230 V

- Type of power source AC voltage

Equipment type Wi-Fi 2.4GHz b/g/n20/n40

Geo-location capability No

Report No: 2498ERM.005A1 Page 20 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

DESCRIPTION OF TEST CONDITIONS

TEST DESCRIPTION
CONDITIONS
Power supply (V):
230 V AC
Test Frequencies for Conducted/ Radiated tests:
TC#01
Lowest channel: 2412 MHz
(b mode)
Middle Channel: 2442 MHz
Highest channel: 2472 MHz

Power supply (V):


230 V AC
TC#02 Test Frequencies for Conducted/ Radiated tests:
(g mode) Lowest channel: 2412 MHz
Middle Channel: 2442 MHz
Highest channel: 2472 MHz

Power supply (V):


230 V AC
Test Frequencies for Conducted/ Radiated tests:
TC#03
Lowest channel: 2412 MHz
(N20 mode)
Middle Channel: 2442 MHz
Highest channel: 2472 MHz

Power supply (V):


230 V AC
Test Frequencies for Conducted/ Radiated tests:
TC#04
Lowest channel: 2422 MHz
(N40 mode)
Middle Channel: 2442 MHz
Highest channel: 2462 MHz

Report No: 2498ERM.005A1 Page 21 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST 4.3.2.2: TRANSMITTER. RF OUTPUT POWER.

Product standard: ETSI EN 300 328 v.2.1.1 (2016-11):


LIMITS:
Test standard: Section 4.3.2.2

LIMITS
For adaptive equipment using wide band modulations other than FHSS, the maximum RF output power shall
be 20 dBm.
The maximum RF output power for non-adaptive equipment shall be declared by the supplier and shall not exceed
20 dBm. For non-adaptive equipment using wide band modulations other than FHSS, the maximum RF output
power shall be equal to or less than the value declared by the manufacturer.
This limit shall apply for any combination of power level and intended antenna assembly.

TEST SETUP:

Report No: 2498ERM.005A1 Page 22 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#01 (b mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a Non-adaptive mode.

Antenna assembly declared gain (dBi) = 2.8 dBi.

Transmitter power e.i.r.p. (dBm)


TEST CONDITIONS Lowest frequency Middle frequency Highest frequency
Tn Vn 19 18.8 18.7

Tmin Vn 19.1 19 19.3

Tmax Vn 18 18.2 18

Measurement uncertainty <0.66 dB


Note: P is the e.i.r.p. as defined in clause 5.4.2.2.1.2 step 6

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#02 (g mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a Non-adaptive mode.
Antenna assembly declared gain (dBi) = 2.8 dBi.

Transmitter power e.i.r.p. (dBm)


TEST CONDITIONS Lowest frequency Middle frequency Highest frequency
Tn Vn 17.3 17.2 17

Tmin Vn 17.4 17.1 17.1

Tmax Vn 18.2 18.3 18.1

Measurement uncertainty <0.66 dB


Note: P is the e.i.r.p. as defined in clause 5.4.2.2.1.2 step 6

Report No: 2498ERM.005A1 Page 23 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#03 (n20 mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a Non-adaptive mode.

Antenna assembly declared gain (dBi) = 2.8 dBi.

Transmitter power e.i.r.p. (dBm)


TEST CONDITIONS Lowest frequency Middle frequency Highest frequency
Tn Vn 17.1 17.1 17

Tmin Vn 17.3 17 17.1

Tmax Vn 16.5 16.7 16.7

Measurement uncertainty <0.66 dB


Note: P is the e.i.r.p. as defined in clause 5.4.2.2.1.2 step 6

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#04 (n40 mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a Non-adaptive mode.
Antenna assembly declared gain (dBi) = 2.8 dBi.

Transmitter power e.i.r.p. (dBm)


TEST CONDITIONS Lowest frequency Middle frequency Highest frequency
Tn Vn 16.4 16.4 16.6

Tmin Vn 16.6 16.8 16.6

Tmax Vn 16.5 16.5 16.5

Measurement uncertainty <0.66 dB


Note: P is the e.i.r.p. as defined in clause 5.4.2.2.1.2 step 6

Report No: 2498ERM.005A1 Page 24 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST 4.3.2.3: TRANSMITTER. POWER SPECTRAL DENSITY.

Product standard: ETSI EN 300 328 v.2.1.1 (2016-11):


LIMITS:
Test standard: Section 4.3.2.3

LIMITS
For equipment using wide band modulations other than FHSS, the maximum Power Spectral Density is limited to
10 dBm per MHz

TEST SETUP:

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#01 (b mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a non-adaptive mode.

Lowest frequency Middle frequency Highest frequency


2412 MHz 2442 MHz 2472 MHz
Measured power density (dBm) 8.260 8.111 7.987
Measurement uncertainty <0.95 dB

Report No: 2498ERM.005A1 Page 25 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel Low

Channel Middle

Channel High

Report No: 2498ERM.005A1 Page 26 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Measurement
Setting Instrument Instrument Instrument
Value Value Value
Start Frequency 2.40000 GHz 2.40000 GHz 2.40000 GHz
Stop Frequency 2.48350 GHz 2.48350 GHz 2.48350 GHz
Span 83.500 MHz 83.500 MHz 83.500 MHz
RBW 10.000 kHz 10.000 kHz 10.000 kHz
VBW 30.000 kHz 30.000 kHz 30.000 kHz
SweepPoints 8351 8351 8351
Sweeptime 20.000 s 20.000 s 20.000 s
Reference Level 20.000 dBm 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB 40.000 dB
Detector RMS RMS RMS
SweepCount 2 2 2
Filter 3 dB 3 dB 3 dB
Trace Mode Max Hold Max Hold Max Hold
Sweeptype Sweep Sweep Sweep
Preamp off off off

Report No: 2498ERM.005A1 Page 27 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#02 (g mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a non-adaptive mode.

Lowest frequency Middle frequency Highest frequency


2412 MHz 2442 MHz 2472 MHz
Measured power density (dBm) 2.961 2.947 2.822
Measurement uncertainty <0.95 dB

Channel Low

Channel Middle

Report No: 2498ERM.005A1 Page 28 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel High

Measurement
Setting Instrument Instrument Instrument
Value Value Value
Start Frequency 2.40000 GHz 2.40000 GHz 2.40000 GHz
Stop Frequency 2.48350 GHz 2.48350 GHz 2.48350 GHz
Span 83.500 MHz 83.500 MHz 83.500 MHz
RBW 10.000 kHz 10.000 kHz 10.000 kHz
VBW 30.000 kHz 30.000 kHz 30.000 kHz
SweepPoints 8351 8351 8351
Sweeptime 168.000 s 168.000 s 168.000 s
Reference Level 20.000 dBm 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB 40.000 dB
Detector RMS RMS RMS
SweepCount 2 2 2
Filter 3 dB 3 dB 3 dB
Trace Mode Max Hold Max Hold Max Hold
Sweeptype Sweep Sweep Sweep
Preamp off off off

Report No: 2498ERM.005A1 Page 29 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#03 (n20 mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a non-adaptive mode.

Bandwidth: 20 MHz

Lowest frequency Middle frequency Highest frequency


2412 MHz 2442 MHz 2472 MHz
Measured power density (dBm) 2.611 2.586 2.492
Measurement uncertainty <0.95 dB

Channel Low

Channel Middle

Report No: 2498ERM.005A1 Page 30 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel High

Measurement
Setting Instrument Instrument Instrument
Value Value Value
Start Frequency 2.40000 GHz 2.40000 GHz 2.40000 GHz
Stop Frequency 2.48350 GHz 2.48350 GHz 2.48350 GHz
Span 83.500 MHz 83.500 MHz 83.500 MHz
RBW 10.000 kHz 10.000 kHz 10.000 kHz
VBW 30.000 kHz 30.000 kHz 30.000 kHz
SweepPoints 8351 8351 8351
Sweeptime 168.000 s 168.000 s 168.000 s
Reference Level 20.000 dBm 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB 40.000 dB
Detector RMS RMS RMS
SweepCount 2 2 2
Filter 3 dB 3 dB 3 dB
Trace Mode Max Hold Max Hold Max Hold
Sweeptype Sweep Sweep Sweep
Preamp off off off

Report No: 2498ERM.005A1 Page 31 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#04 (n40 mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a non-adaptive mode.

Bandwidth: 20 MHz

Lowest frequency Middle frequency Highest frequency


2412 MHz 2442 MHz 2462 MHz
Measured power density (dBm) -0.789 -0.985 -0.797
Measurement uncertainty <0.95 dB

Channel Low

Channel Middle

Report No: 2498ERM.005A1 Page 32 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel High

Measurement
Setting Instrument Instrument Instrument
Value Value Value
Start Frequency 2.40000 GHz 2.40000 GHz 2.40000 GHz
Stop Frequency 2.48350 GHz 2.48350 GHz 2.48350 GHz
Span 83.500 MHz 83.500 MHz 83.500 MHz
RBW 10.000 kHz 10.000 kHz 10.000 kHz
VBW 30.000 kHz 30.000 kHz 30.000 kHz
SweepPoints 8351 8351 8351
Sweeptime 168.000 s 168.000 s 168.000 s
Reference Level 20.000 dBm 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB 40.000 dB
Detector RMS RMS RMS
SweepCount 2 2 2
Filter 3 dB 3 dB 3 dB
Trace Mode Max Hold Max Hold Max Hold
Sweeptype Sweep Sweep Sweep
Preamp off off off

Report No: 2498ERM.005A1 Page 33 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST 4.3.2.6: ADAPTIVITY

Product standard: ETSI EN 300 328 v.2.1.1 (2016-11):


LIMITS:
Test standard: Section 4.3.2.6
LIMITS
The equipment has implemented a LBT based DAA mechanism, which is Load Based equipment.

The limits are defined in clause 4.3.2.6.3.2.3. step 3.

TEST SETUP(Cont.):

Report No: 2498ERM.005A1 Page 34 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#01 (n mode)

TEST RESULTS: PASS

a) Operating Channel: Channel 2412 MHz


Bandwidth: 20 MHz
Normal Operation

Reaction on Interferer

Reaction on Blocker

Report No: 2498ERM.005A1 Page 35 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS(Cont.)

Report No: 2498ERM.005A1 Page 36 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS(Cont.)

Report No: 2498ERM.005A1 Page 37 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS(Cont.)

Report No: 2498ERM.005A1 Page 38 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST 4.3.2.7: OCCUPIED CHANNEL BANDWIDTH.

Product standard: ETSI EN 300 328 v.2.1.1 (2016-11):


LIMITS:
Test standard: Section 4.3.2.7

LIMITS
The Occupied Channel Bandwidth shall fall completely within the 2400 – 2483.5 MHz band.
In addition, for non-adaptive systems using wide band modulations other than FHSS and with e.i.r.p greater than
10 dBm, the occupied channel bandwidth shall be less than 20 MHz

TEST SETUP:

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#01 (b mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a non-adaptive mode.
e.i.r.p. < 10 dBm

Channel Channel Center Frequency Occupied Channel Band Edge (MHz)


(MHz) Bandwidth (MHz)
Lowest 2412 13.168 2405.540373
Highest 2472 13.168 2465.540373
Measurement uncertainty < 1.31 kHz

Report No: 2498ERM.005A1 Page 39 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel Low

Channel High

Report No: 2498ERM.005A1 Page 40 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Measurement
Setting Instrument Instrument
Value Value
Start Frequency 2.39200 GHz 2.45200 GHz
Stop Frequency 2.43200 GHz 2.49200 GHz
Span 40.000 MHz 40.000 MHz
RBW 500.000 kHz 500.000 kHz
VBW 2.000 MHz 2.000 MHz
SweepPoints 161 161
Sweeptime 1.000 s 1.000 s
Reference Level 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB
Detector RMS RMS
SweepCount 1 1
Filter 3 dB 3 dB
Trace Mode Max Hold Max Hold
Sweeptype Sweep Sweep
Preamp off off
Stablemode Trace Trace
Stablevalue 0.50 dB 0.50 dB
Run 4 / max. 150 7 / max. 150
Stable 3/3 3/3
Max Stable Difference 0.07 dB 0.01 dB

Report No: 2498ERM.005A1 Page 41 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#02 (g mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a non-adaptive mode.
e.i.r.p. < 10 dBm

Channel Channel Center Frequency Occupied Channel Band Edge (MHz)


(MHz) Bandwidth (MHz)
Lowest 2412 16.894 2403.552795
Highest 2472 16.894 2463.552795
Measurement uncertainty < 1.31 kHz

Channel Low

Report No: 2498ERM.005A1 Page 42 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.)

Channel High

Measurement
Setting Instrument Instrument
Value Value
Start Frequency 2.39200 GHz 2.45200 GHz
Stop Frequency 2.43200 GHz 2.49200 GHz
Span 40.000 MHz 40.000 MHz
RBW 500.000 kHz 500.000 kHz
VBW 2.000 MHz 2.000 MHz
SweepPoints 161 161
Sweeptime 1.000 s 1.000 s
Reference Level 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB
Detector RMS RMS
SweepCount 1 1
Filter 3 dB 3 dB
Trace Mode Max Hold Max Hold
Sweeptype Sweep Sweep
Preamp off off
Stablemode Trace Trace
Stablevalue 0.50 dB 0.50 dB
Run 4 / max. 150 4 / max. 150
Stable 3/3 3/3
Max Stable Difference 0.07 dB 0.09 dB

Report No: 2498ERM.005A1 Page 43 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#03 (n20 mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a non-adaptive mode.
e.i.r.p. < 10 dBm
Bandwidth: 20 MHz

Channel Channel Center Frequency Occupied Channel Band Edge (MHz)


(MHz) Bandwidth (MHz)
Lowest 2412 17.888 2403.055901
Highest 2472 17.888 2463.055901
Measurement uncertainty < 1.31 kHz

Channel Low

Report No: 2498ERM.005A1 Page 44 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel High

Measurement
Setting Instrument Instrument
Value Value
Start Frequency 2.39200 GHz 2.45200 GHz
Stop Frequency 2.43200 GHz 2.49200 GHz
Span 40.000 MHz 40.000 MHz
RBW 500.000 kHz 500.000 kHz
VBW 2.000 MHz 2.000 MHz
SweepPoints 161 161
Sweeptime 1.000 s 1.000 s
Reference Level 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB
Detector RMS RMS
SweepCount 1 1
Filter 3 dB 3 dB
Trace Mode Max Hold Max Hold
Sweeptype Sweep Sweep
Preamp off off
Stablemode Trace Trace
Stablevalue 0.50 dB 0.50 dB
Run 4 / max. 150 4 / max. 150
Stable 3/3 3/3
Max Stable Difference 0.03 dB 0.09 dB

Report No: 2498ERM.005A1 Page 45 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#04 (n40 mode)

TEST RESULTS: PASS

Type of equipment: Adaptive Equipment without the possibility to switch to a non-adaptive mode.
e.i.r.p. < 10 dBm
Bandwidth: 20 MHz

Channel Channel Center Frequency Occupied Channel Band Edge (MHz)


(MHz) Bandwidth (MHz)
Lowest 2412 36.770 2403.614907
Highest 2472 36.770 2443.614907
Measurement uncertainty < 1.31 kHz

Channel Low

Report No: 2498ERM.005A1 Page 46 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel High

Measurement
Setting Instrument Instrument
Value Value
Start Frequency 2.38200 GHz 2.42200 GHz
Stop Frequency 2.46200 GHz 2.50200 GHz
Span 80.000 MHz 80.000 MHz
RBW 1.000 MHz 1.000 MHz
VBW 3.000 MHz 3.000 MHz
SweepPoints 161 161
Sweeptime 1.000 s 1.000 s
Reference Level 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB
Detector RMS RMS
SweepCount 1 1
Filter 3 dB 3 dB
Trace Mode Max Hold Max Hold
Sweeptype Sweep Sweep
Preamp off off
Stablemode Trace Trace
Stablevalue 0.50 dB 0.50 dB
Run 4 / max. 150 4 / max. 150
Stable 3/3 3/3
Max Stable Difference 0.12 dB 0.03 dB

Report No: 2498ERM.005A1 Page 47 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST 4.3.2.8: TRANSMITTER UNWANTED EMISSIONS IN THE OUT-OF-BAND (OOB)


DOMAIN.
Product standard: ETSI EN 300 328 v.2.1.1 (2016-11):
LIMITS:
Test standard: Section 4.3.2.8

LIMITS
The transmitter unwanted emissions in the out-of-band domain but outside the allocated band, shall not exceed the
values provided in the next mask:

TEST SETUP:

Report No: 2498ERM.005A1 Page 48 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#01 (b mode)

TEST RESULTS: PASS

Spurious levels operating (conducted).

Channel Low:

Report No: 2498ERM.005A1 Page 49 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel High:

Measurement uncertainty <0.95 dB

Report No: 2498ERM.005A1 Page 50 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Measurement
Setting Instrument Instrument
Value Value
Center Frequency 2.50394 GHz 2.50394 GHz
Span ZeroSpan ZeroSpan
RBW 1.000 MHz 1.000 MHz
VBW 3.000 MHz 3.000 MHz
SweepPoints 27350 27350
Sweeptime 27.350 ms 27.350 ms
Reference Level 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB
Detector RMS RMS
SweepCount 1 1
Filter Channel Channel
Trace Mode Clear Write Clear Write
Sweeptype Sweep Sweep
Preamp off off
Trigger Video Video
Trigger Mode up up
Trigger Level 41.000 % 43.000 %
Trigger Offset 13.675 ms 13.675 ms

Report No: 2498ERM.005A1 Page 51 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#02 (g mode)

TEST RESULTS: PASS

Spurious levels operating (conducted).

Channel Low:

Report No: 2498ERM.005A1 Page 52 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel High:

Measurement uncertainty <0.95 dB

Report No: 2498ERM.005A1 Page 53 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Measurement
Setting Instrument Instrument
Value Value
Center Frequency 2.51679 GHz 2.51679 GHz
Span ZeroSpan ZeroSpan
RBW 1.000 MHz 1.000 MHz
VBW 3.000 MHz 3.000 MHz
SweepPoints 5000 5000
Sweeptime 547.800 µs 547.800 µs
Reference Level 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB
Detector RMS RMS
SweepCount 1 1
Filter Channel Channel
Trace Mode Clear Write Clear Write
Sweeptype Sweep Sweep
Preamp off off
Trigger Video Video
Trigger Mode up up
Trigger Level 41.000 % 44.000 %
Trigger Offset 273.900 µs 273.900 µs

Report No: 2498ERM.005A1 Page 54 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#03 (n20 mode)

TEST RESULTS: PASS

Spurious levels operating (conducted).


Bandwidth: 20 MHz
Channel Low:

Report No: 2498ERM.005A1 Page 55 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel High:

Measurement uncertainty <0.95 dB

Report No: 2498ERM.005A1 Page 56 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Measurement
Setting Instrument Instrument
Value Value
Center Frequency 2.51878 GHz 2.51878 GHz
Span ZeroSpan ZeroSpan
RBW 1.000 MHz 1.000 MHz
VBW 3.000 MHz 3.000 MHz
SweepPoints 5000 5000
Sweeptime 503.800 µs 503.800 µs
Reference Level 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB
Detector RMS RMS
SweepCount 1 1
Filter Channel Channel
Trace Mode Clear Write Clear Write
Sweeptype Sweep Sweep
Preamp off off
Trigger Video Video
Trigger Mode up up
Trigger Level 42.000 % 42.000 %
Trigger Offset 251.900 µs 251.900 µs

Report No: 2498ERM.005A1 Page 57 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#04 (n40 mode)

TEST RESULTS: PASS

Spurious levels operating (conducted).


Bandwidth: 40 MHz
Channel Low:

Report No: 2498ERM.005A1 Page 58 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Channel High:

Measurement uncertainty <0.95 dB

Report No: 2498ERM.005A1 Page 59 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.):

Measurement
Setting Instrument Instrument
Value Value
Center Frequency 2.55654 GHz 2.55654 GHz
Span ZeroSpan ZeroSpan
RBW 1.000 MHz 1.000 MHz
VBW 3.000 MHz 3.000 MHz
SweepPoints 5000 5000
Sweeptime 283.800 µs 283.800 µs
Reference Level 20.000 dBm 20.000 dBm
Attenuation 40.000 dB 40.000 dB
Detector RMS RMS
SweepCount 1 1
Filter Channel Channel
Trace Mode Clear Write Clear Write
Sweeptype Sweep Sweep
Preamp off off
Trigger Video Video
Trigger Mode up up
Trigger Level 42.000 % 42.000 %
Trigger Offset 141.900 µs 141.900 µs

Report No: 2498ERM.005A1 Page 60 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST 4.3.2.9: TRANSMITTER UNWANTED EMISSIONS IN THE SPURIOUS DOMAIN


(RADIATED)
Product standard: ETSI EN 300 328 v.2.1.1 (2016-11):
LIMITS:
Test standard: Section 4.3.2.9

LIMITS
The transmitter unwanted emissions in the spurious domain shall not exceed the values given in the next table:
In case of equipment with antenna connectors, these limits apply to emissions at the antenna port (conducted).
For emissions radiated by the cabinet or emissions radiated by integral antenna equipment (without antenna
connectors), these limits are e.r.p. for emissions up to 1 GHz and e.i.r.p. for emissions above 1 GHz.
Frequency range Maximum power Bandwidth
30 MHz to 47 MHz -36 dBm 100 kHz
47 MHz to 74 MHz -54 dBm 100 kHz
74 MHz to 87,5 MHz -36 dBm 100 kHz
87,5 MHz to 118 MHz -54 dBm 100 kHz
118 MHz to 174 MHz -36 dBm 100 kHz
174 MHz to 230 MHz -54 dBm 100 kHz
230 MHz to 470 MHz -36 dBm 100 kHz
470 MHz to 862 MHz -54 dBm 100 kHz
862 MHz to 1 GHz -36 dBm 100 kHz
1 GHz to 12,75 GHz -30 dBm 1 MHz

TEST SETUP:

All radiated tests were performed in a semi-anechoic chamber. The measurement antenna is situated at a
distance of 3 m for the frequency range 30-1000 MHz (Bilog antenna) and at a distance of 1m for the
frequency range 1-26 GHz (1 GHz-18 GHz and 18 GHz-26 GHz Double ridge horn antennas).
For radiated emissions in the range 1-26 GHz that is performed at a distance closer than the specified
distance, an inverse proportionality factor of 20 dB per decade is used to normalize the measured data for
determining compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation
and orientation was varied to find the maximum radiated emission. It was also rotated 360º and the antenna
height was varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization.

Report No: 2498ERM.005A1 Page 61 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST SETUP (CONT.):

Radiated measurements Setup f < 1 GHz

Radiated measurements setup f > 1 GHz

TESTED SAMPLES: S/02

TESTED CONDITIONS MODES: TC#01 (b mode)

TEST RESULTS: PASS

The levels of spurious emissions were measured as their power when radiated by cabinet and antenna.

Frequency range 30 MHz – 1000 MHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

Frequency range 1 GHz – 12.75 GHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

Report No: 2498ERM.005A1 Page 62 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: Low

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

-4 0

-5 0
Level in dBm

-6 0

-7 0

-8 0

-9 0

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H
T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1M
. a x P e a k -P K + ( S in g le )
R M S (S in g le )

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
181.950500 -59.16 -59.98 H

Result Table Single


Frequency MaxPeak RMS Pol
(MHz) (dBm) (dBm)
181.950500 -60.4 -61.4 H

Report No: 2498ERM.005A1 Page 63 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: High

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

-4 0

-5 0
Level in dBm

-6 0

-7 0

-8 0

-9 0

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H
T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1M
. a x P e a k -P K + ( S in g le )
R M S (S in g le )

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
181.950500 -60.23 -61.30 H
233.991000 -63.65 -65.14 V
415.963000 -58.15 -58.92 V

Report No: 2498ERM.005A1 Page 64 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: Low

5
0

-1 0

-2 0
Level in dBm

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .
-3 0

-4 0

-5 0

-6 0

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol Comment
(MHz) (dBm) (dBm)
2413.250000 -0.41 -3.48 H Fundamental
4824.062500 -45.68 -50.63 V

Report No: 2498ERM.005A1 Page 65 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: High

5
0

-1 0

-2 0
Level in dBm

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .
-3 0

-4 0

-5 0

-6 0

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol Comment
(MHz) (dBm) (dBm)
2473.166667 -0.46 -3.43 H Fundamental
4944.312500 -46.53 -53.51 V

Report No: 2498ERM.005A1 Page 66 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/02

TESTED CONDITIONS MODES: TC#02 (g mode)

TEST RESULTS: PASS

The level of spurious emissions was measured as their power when radiated by cabinet and antenna.

Frequency range 30 MHz – 1000 MHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

Frequency range 1 GHz – 12.75 GHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: Low

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

-4 0

-5 0
Level in dBm

-6 0

-7 0

-8 0

-9 0

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
181.950500 -59.54 -60.22 H
415.963000 -54.71 -55.06 V

Report No: 2498ERM.005A1 Page 67 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: High

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

-4 0

-5 0
Level in dBm

-6 0

-7 0

-8 0

-9 0

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations

Frequency PK+_MAXH RMS_MAXH Pol


(MHz) (dBm) (dBm)
181.950500 -59.86 -60.90 H
415.963000 -56.56 -57.14 V

Report No: 2498ERM.005A1 Page 68 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: Low

5
0

-1 0

-2 0
Level in dBm

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .
-3 0

-4 0

-5 0

-6 0

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations

Frequency PK+_MAXH RMS_MAXH Pol Comment


(MHz) (dBm) (dBm)
2412.083333 -0.61 -7.43 V Fundamental
2460.000000 -42.09 -48.19 V

Report No: 2498ERM.005A1 Page 69 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: High

5
0

-1 0

-2 0
Level in dBm

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .
-3 0

-4 0

-5 0

-6 0

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol Comment
(MHz) (dBm) (dBm)
2473.250000 -0.29 -6.33 V Fundamental
4172.031250 -47.77 -55.87 V

Report No: 2498ERM.005A1 Page 70 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/02

TESTED CONDITIONS MODES: TC#03 ( n20 mode)

TEST RESULTS: PASS

The level of spurious emissions was measured as their power when radiated by cabinet and antenna.

Frequency range 30 MHz – 1000 MHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

Frequency range 1 GHz – 12.75 GHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: Low

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

-4 0

-5 0
Level in dBm

-6 0

-7 0

-8 0

-9 0

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
181.950500 -59.44 -60.66 H
233.991000 -59.69 -60.80 V
389.967000 -57.42 -57.86 H
649.975500 -55.90 -56.80 V

Report No: 2498ERM.005A1 Page 71 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: High

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

-4 0

-5 0
Level in dBm

-6 0

-7 0

-8 0

-9 0

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
181.950500 -60.15 -60.89 H
233.991000 -59.58 -60.51 V
389.967000 -59.22 -60.05 H
649.975500 -56.47 -58.14 V

Report No: 2498ERM.005A1 Page 72 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: Low

5
0

-1 0

-2 0
Level in dBm

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .
-3 0

-4 0

-5 0

-6 0

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol Comment
(MHz) (dBm) (dBm)
2414.416667 -0.03 -7.03 V Fundamental
5281.093750 -45.82 -53.93 V

Report No: 2498ERM.005A1 Page 73 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: High

5
0

-1 0

-2 0
Level in dBm

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .
-3 0

-4 0

-5 0

-6 0

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol Comment
(MHz) (dBm) (dBm)
2474.500000 -0.69 -7.01 V Fundamental
10705.343750 -46.71 -54.83 V

Report No: 2498ERM.005A1 Page 74 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/02

TESTED CONDITIONS MODES: TC#04 (n40 mode)

TEST RESULTS: PASS

The level of spurious emissions was measured as their power when radiated by cabinet and antenna.

Frequency range 30 MHz – 1000 MHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

Frequency range 1 GHz – 12.75 GHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: Low

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

-4 0

-5 0
Level in dBm

-6 0

-7 0

-8 0

-9 0

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H
T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1M
. a x P e a k -P K + ( S in g le )
R M S (S in g le )

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
696.050500 -54.85 -59.53 V

Result Table Single


Frequency MaxPeak RMS Pol
(MHz) (dBm) (dBm)
696.050500 -56.1 -65.1 V

Report No: 2498ERM.005A1 Page 75 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: High

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

-4 0

-5 0
Level in dBm

-6 0

-7 0

-8 0

-9 0

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H
T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1M
. a x P e a k -P K + ( S in g le )
R M S (S in g le )

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
696.002000 -54.88 -59.87 V
817.446000 -53.79 -58.36 V

Result Table_Single
Frequency MaxPeak RMS Pol
(MHz) (dBm) (dBm)
696.002000 -55.1 -64.0 V
817.446000 -68.7 -79.1 V

Report No: 2498ERM.005A1 Page 76 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: Low

5
0

-1 0

-2 0
Level in dBm

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .
-3 0

-4 0

-5 0

-6 0

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol Comment
(MHz) (dBm) (dBm)
2422.333333 -7.66 -14.21 V Fundamental
5062.937500 -47.27 -54.48 V

Report No: 2498ERM.005A1 Page 77 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: High

5
0

-1 0

-2 0
Level in dBm

T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .
-3 0

-4 0

-5 0

-6 0

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H T X limits to S p u rio u s E m is s io n E N 3 0 0 3 2 8 V 2 .1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol Comment
(MHz) (dBm) (dBm)
2462.166667 -5.39 -14.78 V Fundamental
4924.000000 -47.68 -55.18 V

Report No: 2498ERM.005A1 Page 78 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST 4.3.2.10: RECEIVER SPURIOUS EMISSIONS (RADIATED)

Product standard: ETSI EN 300 328 v.2.1.1 (2016-11):


LIMITS:
Test standard: Section 4.3.2.10

LIMITS
In case of equipment with antenna connectors, these limits apply to emissions at the antenna port (conducted).
For emissions radiated by the cabinet or emissions radiated by integral antenna equipment (without antenna
connectors), these limits are e.r.p. for emissions up to 1 GHz and e.i.r.p. for emissions above 1 GHz.

Frequency Range Maximum power Measurement bandwidth


30 MHz - 1 GHz -57 dBm 100 kHz
1 GHz - 12.75 GHz -47 dBm 1 MHz

TEST SETUP:

All radiated tests were performed in a semi-anechoic chamber. The measurement antenna is situated at a
distance of 3 m for the frequency range 30-1000 MHz (Bilog antenna) and at a distance of 1m for the
frequency range 1-26 GHz (1 GHz-18 GHz and 18 GHz-26 GHz Double ridge horn antennas).
For radiated emissions in the range 1-26 GHz that is performed at a distance closer than the specified
distance, an inverse proportionality factor of 20 dB per decade is used to normalize the measured data for
determining compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation
and orientation was varied to find the maximum radiated emission. It was also rotated 360º and the antenna
height was varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization.

Report No: 2498ERM.005A1 Page 79 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST SETUP (CONT.):

Radiated measurements Setup f < 1 GHz

Radiated measurements setup f > 1 GHz

TESTED SAMPLES: S/02

TESTED CONDITIONS MODES: TC#01 (b mode)

TEST RESULTS: PASS

The level of spurious emissions was measured as their power when radiated by cabinet and antenna.

Spurious levels operating (radiated).


Frequency range 30 MHz – 1000 MHz
The radiated spurious signals detected for both the lowest and highest operating channels selected were shown
below:

Frequency range 1 GHz – 12.75 GHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown
below:

Report No: 2498ERM.005A1 Page 80 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: Low

-5 5 R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

-6 0

-6 5
Level in dBm

-7 0

-7 5

-8 0

-8 5

-9 0

-9 5

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H
R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1M
. a x P e a k -P K + ( S in g le )
R M S (S in g le )

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
415.963000 -58.82 -59.84 V
480.031500 -52.63 -61.56 V
672.043000 -59.21 -62.40 V
696.050500 -56.06 -60.28 V
720.009500 -59.65 -61.37 H
909.935500 -59.60 -62.23 V

Result Table_Single
Frequency MaxPeak RMS Pol
(MHz) (dBm) (dBm)
415.963000 -58.4 -64.3 V
480.031500 -50.0 -70.9 V
672.043000 -58.6 -66.6 V
696.050500 -65.0 -75.3 V
720.009500 -58.6 -62.0 H
909.935500 -60.4 -66.9 V

Report No: 2498ERM.005A1 Page 81 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: High

-5 5 R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

-6 0

-6 5
Level in dBm

-7 0

-7 5

-8 0

-8 5

-9 0

-9 5

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H
R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1M
. a x P e a k -P K + ( S in g le )
R M S (S in g le )

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
415.963000 -59.33 -60.12 V
479.983000 -53.12 -62.65 V
672.043000 -59.08 -62.52 V
696.002000 -55.81 -60.54 V
720.009500 -60.41 -61.93 H
909.935500 -60.86 -62.59 V

Result Table Single


Frequency MaxPeak RMS Pol
(MHz) (dBm) (dBm)
415.963000 -58.1 -62.5 V
479.983000 -51.2 -70.7 V
672.043000 -58.8 -67.3 V
696.002000 -55.2 -63.7 V
720.009500 -58.3 -61.9 H
909.935500 -61.5 -69.7 V

Report No: 2498ERM.005A1 Page 82 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: Low

-4 5 R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

-5 0

-5 5
Level in dBm

-6 0

-6 5

-7 0

-7 5

-8 0

-8 5

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

Maximizations

Frequency PK+_MAXH RMS_MAXH Pol


(MHz) (dBm) (dBm)
1439.645833 -53.60 -64.43 V
2209.760417 -60.95 -63.11 H
2499.593750 -58.15 -60.08 V
4999.406250 -57.74 -61.20 V

Report No: 2498ERM.005A1 Page 83 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: High

-4 5 R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

-5 0

-5 5
Level in dBm

-6 0

-6 5

-7 0

-7 5

-8 0

-8 5

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
1440.135417 -53.09 -64.22 H
2499.593750 -58.34 -60.43 V
4999.406250 -57.84 -61.87 V

Report No: 2498ERM.005A1 Page 84 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TESTED SAMPLES: S/02

TESTED CONDITIONS MODES: TC#04 (n40 mode)

TEST RESULTS: PASS

The level of spurious emissions was measured as their power when radiated by cabinet and antenna.

Frequency range 30 MHz – 1000 MHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

Frequency range 1 GHz – 12.75 GHz


The radiated spurious signals detected for both the lowest and highest operating channels selected were shown below:

30 MHz – 1000 MHz


TEST RESULTS (Cont.):
Channel: Low

-5 5 R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

-6 0

-6 5
Level in dBm

-7 0

-7 5

-8 0

-8 5

-9 0

-9 5

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H
R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1M
. a x P e a k -P K + ( S in g le )
R M S (S in g le )

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
415.963000 -59.30 -60.35 V
479.983000 -53.37 -62.89 V
672.043000 -58.24 -62.00 V
696.002000 -56.17 -60.99 V
720.009500 -59.35 -61.27 H

Result Table Single


Frequency MaxPeak RMS Pol
(MHz) (dBm) (dBm)
415.963000 -58.3 -62.8 V
479.983000 -57.4 -73.7 V
672.043000 -58.5 -65.1 V
696.002000 -54.4 -61.2 V
720.009500 -58.4 -61.3 H

Report No: 2498ERM.005A1 Page 85 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

30 MHz – 1000 MHz


TEST RESULTS (Cont.):

Channel: High

-5 5 R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

-6 0

-6 5
Level in dBm

-7 0

-7 5

-8 0

-8 5

-9 0

-9 5

30M 50 60 80 100M 200 300 400 500 800 1G


F re q u e n c y in H z

R M S _M A XH P K+_M AX H
R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1M
. a x P e a k -P K + ( S in g le )
R M S (S in g le )

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
129.958500 -62.83 -63.55 H
415.963000 -59.84 -60.56 V
672.043000 -59.40 -62.73 V
696.002000 -54.71 -59.29 V
720.009500 -60.07 -61.54 H

Result Table_Single
Frequency MaxPeak RMS Pol
(MHz) (dBm) (dBm)
129.958500 -64.5 -65.4 H
415.963000 -58.8 -63.6 V
672.043000 -58.4 -64.3 V
696.002000 -54.6 -61.8 V
720.009500 -58.0 -62.1 H

Report No: 2498ERM.005A1 Page 86 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: Low

-4 5 R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

-5 0

-5 5
Level in dBm

-6 0

-6 5

-7 0

-7 5

-8 0

-8 5

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

Maximizations
Frequency PK+_MAXH RMS_MAXH Pol
(MHz) (dBm) (dBm)
2209.760417 -61.25 -64.14 H
2499.593750 -58.56 -60.25 V
4999.406250 -58.38 -62.84 V

Report No: 2498ERM.005A1 Page 87 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

1 GHz – 12.75 GHz


TEST RESULTS (Cont.):

Channel: High

-4 5 R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

-5 0

-5 5
Level in dBm

-6 0

-6 5

-7 0

-7 5

-8 0

-8 5

1G 2G 3G 4G 5G 6 8 1 2 .7 5 G
F re q u e n c y in H z

R M S _M A XH P K+_M AX H R X lim it s t o S p u rio u s E m iss io n E N 3 0 0 3 2 8 V 2 . 1 .1 .

Maximizations

Frequency PK+_MAXH RMS_MAXH Pol


(MHz) (dBm) (dBm)
2209.760417 -60.65 -63.98 H
2499.593750 -57.97 -59.75 V
4999.406250 -58.87 -62.04 V

Report No: 2498ERM.005A1 Page 88 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST 4.3.2.11: RECEIVER BLOCKING

Product standard: ETSI EN 300 328 v.2.1.1 (2016-11):


LIMITS:
Test standard: Section 4.3.2.11

The minimum performance criterion shall be a PER less than or equal to 10 %. The manufacturer may declare
alternative performance criteria as long as that is appropriate for the intended use of the equipment (see
application form section t)).
The blocking levels at specified frequency offsets shall be equal to or greater than the limits defined for the
applicable receiver category provided in table 14, table 15 or table 16.

Report No: 2498ERM.005A1 Page 89 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST SETUP(Cont.):

TESTED SAMPLES: S/01

TESTED CONDITIONS MODES: TC#01 (b mode)

TEST RESULTS: PASS

Equipment Category: 1
a) Operating Channel: Low channel center frequency 2412 MHz / b mode / 11Mbps
Declared Bandwidths: 20 MHz
Wanted signal sensitivity level (Pmin) at 2412 MHz: -90 dBm
Blocking signal frequency (MHz) Blocking Signal power PER PER Result
level corrected by the
% Limit
actual antenna
%
assembly gain (dBm)
2380 -50.2 1.5 10 P
2503.5 -50.2 1.8 10
P
2300 -44.2 1.4 10
P
2330 -44.2 1.3 10
P
2360 -44.2 1.1 10 P
2523.5 -44.2 1.2 10 P
2553.5 -44.2 1.3 10 P
2583.5 -44.2 1.5 10 P
2613.5 -44.2 1.1 10 P
2643.5 -44.2 1.2 10 P
2673.5 -44.2 1.7 10 P

Measurement uncertainty (dB) < 2.44 dB

Report No: 2498ERM.005A1 Page 90 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

TEST RESULTS (Cont.)

a) Operating Channel: High channel center frequency 2472 MHz / b mode / 11Mbps
Declared Bandwidths: 20 MHz
Wanted signal sensitivity level (Pmin) at 2472 MHz: -89 dBm
Blocking signal frequency (MHz) Blocking Signal power PER PER Result
level corrected by the
% Limit
actual antenna
%
assembly gain (dBm)
2380 -50.2 1.9 10 P
2503.5 -50.2 1.7 10
P
2300 -44.2 1.5 10
P
2330 -44.2 1.0 10
P
2360 -44.2 1.3 10 P
2523.5 -44.2 1.3 10 P
2553.5 -44.2 1.5 10 P
2583.5 -44.2 1.7 10 P
2613.5 -44.2 1.9 10 P
2643.5 -44.2 1.3 10 P
2673.5 -44.2 1.2 10 P

Measurement uncertainty (dB) < 2.44 dB

Report No: 2498ERM.005A1 Page 91 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Appendix C: Photographs

Report No: 2498ERM.005A1 Page 92 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Figure C1. DUT Side+ Front View

Figure C2. DUT Side+ Rear View

Report No: 2498ERM.005A1 Page 93 of 94 09-30-2019


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America

Figure C3. Radiated Setup – Low Range

Figure C4. Radiated Setup- High Range

Report No: 2498ERM.005A1 Page 94 of 94 09-30-2019

You might also like