WIND PRESSURE COEFFICIENTS


In accordance with AS 1170.2:2021
Tedds calculation version 1.0.05

Aerodynamic shape factor for enclosed building (cl. 5.2a)


The following calculations collate the internal and external pressure coefficients for an enclosed rectangular building.
The coefficients have been combined with wind pressures for each orthogonal direction. The combination of the external and
internal pressures needs to be conducted separately. When combining the pressures, the Combination factors, K c,e & Kc,i
(refer to Table 5.5 for appropriate values of K c,e & Kc,i), and the Area reduction factor, Ka, need to be included. The Area
reduction factor, Ka, makes the pressure applicable to the specific structural element and force being considered.
No local pressure factor (Kl) has been included in the following calculations and this should be considered separately.
No consideration or reduction has been made for permeable cladding (K p) in the calculation.
External pressures; Cshp = Cp.e  Ka  Kc,e  Kl  Kp
Internal pressures; Cshp = Cp.i  Kc,i  Kv

External pressure coefficients for enclosed rectangular buildings (cl. 5.4)


Building dimensions; h = 13.3 m
AA = 42.0 m
BB = 12.9 m
Roof slope;  = 31.0 
Ratios for  = 0/180; d_on_b0 = BB / AA = 0.31
h_on_d0 = h / BB = 1.03
0 = 
Ratios for  = 90/270; d_on_b90 = AA / BB = 3.25
h_on_d90 = h / AA = 0.32
90 = 

Enclosed rectangular
buildings - hip roofs

Coefficients for Hip roof when  10;


Orthogonal direction
Roof
0/180 90/270
Cp.e.U10 Cp.e.U20 Cp.e.U190 Cp.e.U290
T5.3B (U)
-0.28 0.22 -0.17 0.39
T5.3C Cp.e.D10 Cp.e.D190
Project Job Ref.
J220088 - 159-165 John St, Lidcombe - LATEST DRAWINGS J220088

Neilly Davies Consulting Engineers Section Sheet no./rev.

Lanka (Pvt) Ltd Wind Coefficient cal 2


39 Pirappankulam Road Calc. by Date Chk'd by Date App'd by Date
Jaffna RAM 9/7/2022 MADHU 9/7/2022 BALA 9/7/2022

(D) & (R) -0.60 -0.60


Coefficients for Windward and Leeward walls in each orthogonal direction;
Orthogonal direction
Walls
0 90 180 270
Windward Cp.e.W0 Cp.e.W90 Cp.e.W180 Cp.e.W270
T5.2A
0.70 0.80 0.70 0.80
(W);
Leeward Cp.e.L0 Cp.e.L90 Cp.e.L180 Cp.e.L270
T5.2B
-0.50 -0.50 -0.50 -0.50
(L);
Coefficients for Side walls in each orthogonal direction;
Horizontal T5.2C - Side walls (S)
distance
from Orthogonal direction
windward
edge 0 90 180 270

Cp.e.S.0_1h0 Cp.e.S.0_1h90 Cp.e.S.0_1h180 Cp.e.S.0_1h270


0 to 1h
-0.65 -0.65 -0.65 -0.65
Cp.e.S.1_2h0 Cp.e.S.1_2h90 Cp.e.S.1_2h180 Cp.e.S.1_2h270
1h to 2h
-0.5 -0.5 -0.5 -0.5
Cp.e.S.2_3h0 Cp.e.S.2_3h90 Cp.e.S.2_3h180 Cp.e.S.2_3h270
2h to 3h
-0.3 -0.3 -0.3 -0.3
Cp.e.S.3h0 Cp.e.S.3h90 Cp.e.S.3h180 Cp.e.S.3h270
>3h
-0.2 -0.2 -0.2 -0.2
From Table 5.1(a) - Internal pressure coefficients for buildings - cases for wall without openings greater than 0.5% of the wall
area and an impermeable roof.

AA

North
y

x x BB

Condition - effectively sealed


Minimum Cpi; Cp.i.10 = Cp.i.190 = Cp.i.1180 = Cp.i.1270 = -0.2
Maximum Cpi; Cp.i.20 = Cp.i.290 = Cp.i.2180 = Cp.i.2270 = 0.0