You are on page 1of 1

EV86 Error Code Definitions, August 2010

Error Error
Description Error display Description Error display
code code
1 Insufficient presence. rFEEd 138 Magnetic detector not calibrated. UnCAL dEt
2 Gulp seen at double detect guLP 139 Guard against a stream feed with folded double. rFEEd
3 Half note at double detect hALF 140 Marginal double? rFEEd
4 Torn note at double detect rFEEd 141 Insufficient length on LHS and RHS for a double. rFEEd
5 First note too long at double detect. rFEEd 142 Double detector conflict with Size detector. rFEEd
6 Mismatch between left and right double detect rFEEd 143 Gulp feed seen on double detect. rFEEd
7 Short note at double detect. rFEEd 144 Second note thinner on either side of double detect. rFEEd
8 Long note at double detect rFEEd 146 Insufficient single and double lengths. rFEEd
9 Insufficient length on RHS and track sensor for a double. rFEEd 147 PPD detector fault. FAULt
10 Insufficient length on LHS and track sensor for a double. rFEEd 148 PPD detector uncalibrated. UnCAL dEt
11 Double note. rFEEd 149 PPD detector not present has been removed. FAULt
12 Unknown note less than reference rFEEd 150 Magnetic detector present. Found
14 Batch mismatch due to overcount. rFEEd 151 UV bright detector present. Found
15 Overlap double. rFEEd 152 Size detector SD present. Found
16 Note in machine at start up. LASt 153 Size detector 2D present. Found
17 Note in machine on run down. rFEEd 155 Metal thread detector present. Found
18 Note not in found in size table. tAbLE 156 IR detector present. Found
19 Value count near overflow. nEAr 157 SMDS detector present. Found
20 Value count has overflowed. OvEr 158 PPD detector present. Found
21 Feed timeout error. FEEd 159 Twin Magnetic detector uncalibrated FAULt
24 Value display full. FuLL 160 No emag response iSb
28 Last note was a double. rFEEd 161 No synchronize detector response. iSb
29 Double detect data overrun error. rFEEd 162 No magnetic detector response. iSb
30 Clear stacker before start count. CLEAr 163 No UV detector response. iSb
31 Note in machine at power up. CLEAr 164 No size detector response. iSb
32 Note in transport. CLEAr 165 No response from feeder iSb
33 extra track sensor pulse, DN25 only 167 No metal thread detector response. iSb
34 Detector box lid open. Lid 168 No detector response. iSb
35 Incomplete detector scan during run down. rFEEd 169 No LV2 detector response. iSb
36 Note seen at double detect during run down. rFEEd 170 No IR detector response. iSb
37 Invalid detector response. rFEEd 171 No general detector response. iSb
38 Denomination total overflowed. rFEEd 172 No CMS response. iSb
39 Stream feed. rFEEd 173 ISB comms failure. iSb
40 Size detector RHS short edge dimension too short. dEn x 174 No PPD detector response. iSb
41 Size detector RHS short edge dimension too long. dEn x 175 No MAGI detector response. iSb
42 Size detector left and right short edge diff greater than 10mm. dEn x 176 MAGI detector present. Found
43 Note skew limit exceeded. dEn x 177 MAGI not present has been removed. FAULt
44 Size detector LHS short edge dimension too short. dEn x 178 MAGI detector uncalibrated. UnCAL dEt
45 Size detector LHS short edge dimension too long. dEn x 179 MAGI detector fault. FAULt
46 Size detector overrun. dEn x 180 Magnetic detector fault FAULt
47 Size detector long edge dimension too short. dEn x 181 Note not seen by UV bright detector. CF x
48 Size detector long edge dimension too long. dEn x 182 IR result not ready. CF x
49 No note status received from size detector. dEn x 183 Note not seen by size detector. dEn x
50 No note size match found in size table. tAbLE 184 Note not seen by PPD detector. CF x
52 Currency table error. dEn x 190 Size detector not ready. CLEAn det
54 No Mag CF x 191 UV bright detector not ready. CLEAn det
55 UV brightness detector counterfeit note. CF x 192 IR detector not ready. CLEAn det
56 Magnetic detector counterfeit note. CF x 193 SMDS detector not ready. n_rdy det
57 Metal thread detector counterfeit. CF x 194 PPD detector not ready. n_rdy det
58 IR detector counterfeit note. CF x 195 MAGI detector not ready. n_rdy det
59 Unknown IR note dEn x 196 Mag detector not ready n_rdy det
60 Magnetic detector sat/rem ratio counterfeit. CF x 198 SMDS DSP not responding. rFEEd
61 Magnetic detector sat/rem crossover. CF x 199 SMDS invalid DSP response rFEEd
62 Magnetic detector system error. CF x 200 SMDS incorrect denomination. dEn x
64 Corner fold prevented IR check dEn x 201 SMDS code type error. dEn x
65 No Foil FoiL 202 SMDS note not seen. rFEEd
66 Clean stacker sensor. CLEAn 203 SMDS no note status. dEn x
68 Clean track sensor. CLEAn 204 SMDS codes too close. dEn x
74 PPD detector counterfeit note. CF x 205 SMDS out of sync. rFEEd
76 Note not seen by HDIR CF x 206 SMDS calibration error. rFEEd
77 HDIR initialising FAULt 207 SMDS note too short. dEn x
78 HDIR error recovery FAULt 208 SMDS note too long. dEn x
79 HDIR communication error FAULt 209 SMDS incorrect code structure. CF x
80 HDIR timeout eror FAULt 210 SMDS no DSP denomination code response. dEn x
81 HDIR diagnostic error FAULt 211 SMDS DSP link beat failure. rEP
82 HDIR parameter error FAULt 212 SMDS no digital pattern. CF x
83 HDIR not ready FAULt 213 SMDS no sync pulse. CF x
84 HDIR incorrect denomination dEn x 214 SMDS conflicting match. dEn x
85 HDIR no DSP response CF x 215 SMDS scores too low. dEn x
86 invalid command CnS 216 SMDS DSP result not ready. rFEEd
87 HDIR authenticity error CF x 217 SMDS DSP buffer wrapped. rFEEd
88 CMS protocol error CnS 218 SMDS dsp not responding. rFEEd
89 Host comms failure CnS 219 SMDS invalid dsp response. rFEEd
90 Stop invoked by CMS. StoP 220 SMDS DSP excessive note data. dEn x
91 Host reports an error CnS 221 SMDS DSP response timeout to complete process. rFEEd
92 Host logged off CnS 222 SMDS excessive note skew. rFEEd
93 Printer fault CnS 223 SMDS security check failed. CF x
94 Split double CnS 224 MAGI excessive note data. CF x
96 Bad note reported by detectors with no errors log. rFEEd 225 MAGI selected feature absent. CF x
97 Totals Update Error. FAULt 226 MAGI no serial number. CF x
98 HDIR error 1 . CF x 227 MAGI no thread. CF x
99 HDIR error 2 CF x 228 MAGI no magnetic feature. CF x
100 Transport jam. JA 229 MAGI no active algorithm. CF x
101 Left hand double detect error. FAULt 230 MAGI note not seen. CF x
102 Right hand double detect error. FAULt 231 MAGI low threshold. CF x
104 Double detect setup fault. UnCAL dd 232 HDIR DSP Coordinator faults FAULt
106 UV brightness detector fault. FAULt 233 HDIR DSP Coordinator fault 1 FAULt
107 Size detector fault. CLEAn dd 234 HDIR DSP Coordinator fault 2 FAULt
108 Size NOVRAM checksum error FAULt 235 HDIR DSP Coordinator fault 3 FAULt
110 Noise seen on double detect during run. UnCAL dEt 236 HDIR DSP Coordinator fault 4 FAULt
111 UV brightness detector not calibrated. UnCAL dEt 237 HDIR DSP Coordinator fault 5 FAULt
112 Size detector not calibrated. UnCAL dEt 238 HDIR DSP Coordinator fault 6 FAULt
119 Invalid denomination. tAbLE 239 HDIR DSP Coordinator fault 7 FAULt
120 Main controller novram checksum error. FAULt 240 HDIR DSP Coordinator fault 8 FAULt
121 Main controller novram configuration error. FAULt 241 HDIR DSP Coordinator fault 9 FAULt
126 UV detector not present has been removed. FAULt 242 HDIR DSP Coordinator fault 10 FAULt
127 Short edge size detector not present has been removed. FAULt 243 HDIR DSP Coordinator fault 11 FAULt
128 Long edge size detector not present has been removed. FAULt 244 HDIR DSP Coordinator fault 12 FAULt
129 IR detector not present has been removed. FAULt 245 HDIR DSP Coordinator fault 13 FAULt
130 SMDS detector not present has been removed. FAULt 246 HDIR DSP Coordinator fault 14 FAULt
131 SMDS detector dsp download fault. FAULt 247 HDIR DSP Coordinator fault 15 FAULt
132 Magnetic detector not present has been removed. FAULt 248 HDIR DSP Coordinator fault 16 FAULt
133 Metal thread detector not present has been removed. FAULt 249 HDIR DSP Coordinator fault 17 FAULt
134 SMDS detector fault. FAULt 250 Power-up recovery failed. rFEEd
135 IR detector fault. FAULt 251 System configuration error. SEtUP Err
136 SMDS detector not calibrated. UnCAL dEt 255 Unknown error condition. Error
137 IR detector not calibrated. UnCAL dEt