01.

2
NOTES:
1. ALL FIXINGS TO BE COATED TO MATCH FENCE BASE COLOUR AS SPECIFIED.
2. REFER TO LANDSCAPE ARCHITECTURE SPECIFICATION (TAS-HWW-SDL-ZWD-SPC-
AUD-SDU-A0010) FOR ADDITIONAL INFORMATION.
3.REFER TO ENGINEER'S DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.

100 x 6 EQUAL ANGLE


AS SPECIFIED

100 EQ 125 x 6 SHS


HORIZONTAL BEAM
AS SPECIFIED
EQ
125

EQ

0
10
10
0

CONCRETE FOOTING
BELOW - REFER TO
STRUCTURAL ENGINEER
PACKAGE FOR DETAIL
RENDER IMAGE FOR DESIGN INTENT ONLY
1 ISS FENCE PLAN
--- 1 : 10

10MM RADIUS TO ALL EXPOSED


CORNERS OF L-ANGLE CHEVRON PATTERN - REFER TO SCHEDULE FOR
CONCEALED SLEEVE FIXING TO LOCATION AND HEIGHT ON EACH L-ANGLE
CONNECT FENCE UNITS -
REFER TO ENGINEER'S DETAIL

3
_________________________________________
100X6 EQUAL L-ANGLE WELDED TO SHS
3800

VARIES
BOTH ENDS OF LAST UNITS TO BE
CAPPED AND FULLY SEALED.
241 EQ REFER TO ENGINEER'S DEATIL. 125X6 SHS HORIZONTAL BEAM. WEEP HOLES TO
UNDERSIDE - REFER TO ENGINEER'S DETAIL.

100 EQ
U-BRACKET WELDED TO POST. 2 NO'S PRESET
SLOTTED HOLES FOR COUNTERSUNK BOLTS AND NUTS
100X6 EQUAL ANGLE WITH FINISHED FLUSH - REFER TO ENGINEER'S DETAIL.
CHEVRON PATTERN AS
SPECIFIED
VARIES. REFER TO SCHEDULE

CHEVRON PATTERN - REFER TO SCHEDULE


FOR LOCATION AND HEIGHT ON EACH L-ANGLE CONCRETE FOOTING
- REFER TO ENGINEER'S DETAIL
VARIES

125X6 SHS HORIZONTAL BEAM


AS SPECIFIED 100X6 EQUAL L-ANGLE WELDED TO SHS
AS SPECIFIED

125X6 SHS HORIZONTAL BEAM AS SPECIFIED


U-BRACKET WELDED TO CHS.
GROUND - GARDEN BED 2 NO'S PRESET SLOTTED HOLES FOR
COUNTERSUNK BOLTS AND NUTS FINISHED
FLUSH - REFER TO ENGINEER'S DETAIL.
100 125

NOM. 100

MASTIC COVING BEAD BETWEEN


VARIES CONCRETE AND STEEL - REFER TO
ENGINEER'S DETAIL

114X4.8 CHS AS SPECIFIED. APPLY NON-


CONDUCTIVE PAINT TO ENGINEER'S DETAIL
2 ISS FENCE ELEVATION
--- 1 : 20 CONCRETE FOOTING
- REFER TO ENGINEER'S DETAIL

3 TYPICAL SECTION 4 ISS FENCE TYPICAL UNITS


--- 1 : 20 ---
ISSUED FOR REVIEW
Project Drawing Number Revision

TAS-HWW-ARD-AIS-DRG-AUD-AEN-A3800 01.2
23/12/2022 11:08:24 AM

GENERAL NOTES Consultant Drawn By Designed By


1. THESE DRAWINGS FORM A COMPONENT OF THE OVERALL DESIGN
This drawing has been prepared by, or compiled from
information provided by, persons other than PTV. To the
maximum extent permissible by law, PTV takes no responsibility
ARCHITECTURAL J PETITE E SHAW
SOLUTION FOR THE ISS CIVIL - DESIGN PACKAGE TAS-D-CRD-2339-0485.
THEY DO NOT FORM A SEPARATE LANDSCAPE ARCHITECTURE DESIGN
for, and makes no representations in relation to, the
completeness, accuracy or quality of any information contained ARDEN Checked By Ind. Review
PACKAGE.
in this drawing. Each user of this drawing releases PTV from all
and any loss, damage, cost, expense or liability in relation to the ARDEN PRECINCT File Name C GUTHRIE
2. THE DESIGN SCOPE FOR THIS PACKAGE DOES NOT DIRECTLY INTERFACE use of, or any reliance on, this drawing or the information
contained in it.
LANDSCAPE ARCHITECTURE Approved Approval Date
WITH ANY DESIGN PACKAGES OTHER THAN THE ISS CIVIL - DESIGN Franchisee / Lessee FENCE DETAILS - SHEET 01 Sheet No. SHEET 01 OF 02 APPROVER
PACKAGE TAS-D-CRD-2339-0485 (ALSO CONTAINING CIVIL - STORMWATER 01.2 14/10/2022 ISSUED FOR REVIEW ES CG
All written dimensions take precedence over scaled dimensions.
DRAINAGE DESIGN PACKAGE AND CIVIL - COMBINED UTILITIES DESIGN Up Location Down Location Datum Drawing Number Revision
PACKAGE) AND ARCHITECTURAL DESIGN PACKAGE TAS-A-ARC-1022-0441.
01.1 19/05/2022 ISSUED FOR REVIEW ES CG This drawing is provided only for the information of the person
or organisation to whom PTV provides it. It may not be provided East. East. In Serv
3. LEVELS TO AHD. MMRA HEIGHT DATUM = AHD + 100M. Revised By In Serv Rev. Date Description Designed Checked Ind. Rev. Approv. to, or used by, any other person without PTV's prior written North. North. Scale Sheet Size
consent.
ID# ID# As indicated A1
01.2
3600 3860 3600 3600 3600 1800 3620 1800 3190 3900
UNIT A - STRAIGHT UNIT B - CURVED UNIT C - STRAIGHT UNIT D - STRAIGHT UNIT E - STRAIGHT UNIT F - STRAIGHT UNIT G - CURVED UNIT H - STRAIGHT UNIT I - CURVED UNIT J - STRAIGHT

RL +2.925
15 1 7
15 1 7 15 1
7
15 1
7 7

RL +2.575
15 1
RL +2.925
7 1
1 7
15 1
7 1
7 15

INDICATIVE GROUND LINE


1

RL +2.575
7 16
NOM. 100 OFFSET

NOM. 100 OFFSET


2
3800

1 ISS FENCE UNWRAPPED ELEVATION FENCE UNIT SCHEDULE FENCE UNIT SCHEDULE
--- 1 : 50
EQUAL ANGLE UNIT NO. H L1 BTM L1 TOP L2 BTM L2 TOP R3 BTM R3 TOP R3 BTM R4 TOP UNIT NO. H L1 BTM L1 TOP L2 BTM L2 TOP R3 BTM R3 TOP R3 BTM R4 TOP

Unit A 1 930 0 0 0 0 0 0 0 0 Unit E 1 1832 470 620 1100 1250 340 490 1250 1400
Unit A 2 1000 0 150 850 1000 460 560 0 0 Unit E 2 1800 630 780 930 1080 170 320 1400 1550
Unit A 3 1065 120 270 820 970 360 510 580 730 Unit E 3 1763 800 900 0 0 0 150 1613 1763
Unit A 4 1130 250 400 760 910 270 420 740 890 Unit E 4 1756 0 0 0 0 0 0 0 0
Unit A 5 1191 380 530 710 860 180 330 910 1060 Unit E 5 1750 0 150 1600 1750 835 935 0 0
Unit A 6 1253 500 800 0 0 90 240 1080 1230 Unit E 6 1739 150 300 1450 1600 670 820 940 1090
Unit A 7 1309 645 745 0 0 0 150 1158 1309 Unit E 7 1729 310 460 1270 1420 500 650 1100 1250
Unit A 8 1362 0 0 0 0 0 0 0 0 Unit E 8 1721 470 620 1100 1250 340 490 1250 1400

H
Unit A 9 1413 160 310 1263 1413 675 775 820 970 Unit E 9 1712 630 780 930 1080 170 320 1400 1550

L2 TOP
Unit A 10 1460 160 310 1200 1350 520 670 820 970 Unit E 10 1703 800 900 0 0 0 150 1550 1703

R4 TOP
L2 BTM
Unit A 11 1508 320 470 1080 1230 440 550 1000 1150 Unit E 11 1695 0 0 0 0 0 0 0 0

R4 BTM
Unit A 12 1548 480 630 970 1120 260 410 1190 1340 Unit E 12 1685 0 150 1535 1685 795 895 0 0
Unit A 13 1589 630 780 860 1010 130 280 1370 1520 Unit E 13 1668 150 300 1380 1530 630 780 900 1050

R3 TOP
Unit A 14 1627 800 900 0 0 0 150 1472 1627 Unit E 14 1651 300 450 1210 1360 470 620 1040 1190

L1 TOP

R3 BTM
Unit A 15 1661 0 0 0 0 0 0 0 0 Unit E 15 1634 450 600 1040 1190 310 460 1190 1340
Unit B 1 1695 0 150 1545 1695 810 910 0 0 Unit F 1 1625 600 750 880 1030 150 300 1340 1490

L1 BTM
Unit B 2 1727 180 330 1430 1580 660 810 950 1100 Unit F 2 1615 760 860 0 0 0 150 1465 1615
Unit B 3 1755 350 500 1290 1440 480 630 1150 1300 Unit F 3 1612 0 0 0 0 0 0 0 0
Unit B 4 1782 530 680 1130 1280 320 470 1340 1490 Unit F 4 1600 0 150 1450 1600 755 855 0 0
SHS HORIZONTAL BEAM Unit B 5 1804 700 850 980 1130 160 310 1530 1680 Unit F 5 1591 140 290 1310 1460 600 750 850 1000
Unit B 6 1830 880 980 0 0 0 150 1680 1830 Unit F 6 1583 280 430 1150 1300 450 600 990 1140
Unit B 7 1846 0 0 0 0 0 0 0 0 Unit F 7 1583 280 430 1150 1300 450 600 990 1140
R5700 3 ISS FENCE CHEVRON SETOUT DIAGRAM Unit B 8 1860 0 150 1710 1860 890 990 0 0 Unit G 1 1550 570 720 840 990 150 300 1270 1420
--- 1 : 15 Unit B 9 1876 180 330 1560 1710 700 850 1030 1180 Unit G 2 1534 720 820 0 0 0 150 1384 1534
Unit B 10 1888 350 500 1390 1540 520 670 1210 1360 Unit G 3 1516 0 0 0 0 0 0 0 0
Unit B 11 1898 540 690 1210 1360 350 500 1400 1550 Unit G 4 1501 0 150 1350 1500 710 810 0 0
Unit B 12 1904 727 893 1030 1180 170 320 1580 1730 Unit G 5 1482 130 280 1220 1370 570 720 790 940
Unit B 13 1910 910 1010 0 0 0 150 1755 1910 Unit G 6 1466 260 410 1070 1220 420 570 910 1060
Unit B 14 1915 0 0 0 0 0 0 0 0 Unit G 7 1448 400 550 920 1070 280 430 1030 1180
Unit B 15 1918 0 150 1768 1918 915 1015 0 0 Unit G 8 1431 520 670 760 910 130 280 1150 1300
Unit C 1 1925 180 330 1600 1750 740 890 1050 1200 Unit G 9 1414 660 760 0 0 0 150 1264 1414
Unit C 2 1933 360 510 1420 1570 500 700 1240 1390 Unit G 10 1398 0 0 0 0 0 0 0 0
Unit C 3 1938 550 700 1240 1390 370 520 1420 1570 Unit G 11 1380 0 150 1230 1380 650 750 0 0
Unit C 4 1944 740 890 1060 1210 180 330 1620 1770 Unit G 12 1365 110 260 1110 1260 510 660 720 870
Unit C 5 1948 920 1020 0 0 0 150 1796 1948 Unit G 13 1347 240 390 980 1130 380 530 830 980
Unit C 6 1943 0 0 0 0 0 0 0 0 Unit G 14 1332 360 510 830 980 250 400 930 1080
Unit C 7 1953 0 150 1803 1953 920 1020 0 0 Unit G 15 1315 470 620 700 850 120 270 1050 1200
Unit C 8 1954 170 320 1600 1750 730 880 1050 1200 Unit H 1 1299 600 700 0 0 0 150 1150 1299
Unit C 9 1954 350 500 1420 1570 550 700 1230 1380 Unit H 2 1280 0 0 0 0 0 0 0 0

2 ISS FENCE SETOUT PLAN Unit C


Unit C
10
11
1953
1953
540
720
690
870
1230
1050
1380
1200
370
190
520
340
1410
1590
1560
1740
Unit H
Unit H
3
4
1268
1253
0
100
150
250
1118
1000
1268
1150
590
470
690
620
0
650
0
800
--- 1 : 50
Unit C 12 1950 900 1000 0 0 0 150 1800 1950 Unit H 5 1238 210 360 870 1020 350 500 740 890
Unit C 13 1948 0 0 0 0 0 0 0 0 Unit H 6 1222 320 470 750 900 230 380 840 990
Unit C 14 1945 0 150 1795 1945 900 1000 0 0 Unit H 7 1207 420 570 620 770 110 260 940 1090
Unit C 15 1941 170 320 1570 1720 710 860 1030 1180 Unit I 1 1192 540 640 0 0 0 150 1037 1192
Unit D 1 1937 350 511 1401 1536 542 698 1201 1347 Unit I 2 1177 0 0 0 0 0 0 0 0
Unit D 2 1932 520 670 1200 1350 360 510 1370 1520 Unit I 2 1167 0 150 1010 1167 530 630 0 0
Unit D 3 1926 700 850 1010 1160 180 330 1550 1700 Unit I 4 1149 90 240 790 1050 420 720 0 0
Unit D 4 1920 875 975 0 0 0 150 1770 1920 Unit I 5 1135 190 340 790 940 310 460 670 820
Unit D 5 1915 0 0 0 0 0 0 0 0 Unit I 6 1120 290 400 680 830 210 360 760 910
Unit D 6 1912 0 150 1760 1912 870 970 0 0 Unit I 7 1097 400 700 0 0 100 250 850 1000
Unit D 7 1903 160 310 1520 1670 700 850 990 1140 Unit I 8 1092 490 590 0 0 0 150 942 1092
Unit D 8 1896 330 480 1340 1490 520 670 1150 1300 Unit I 9 1080 0 0 0 0 0 0 0 0
Unit D 9 1888 500 650 1150 1300 350 500 1310 1460 Unit I 10 1063 0 150 910 1063 480 580 0 0
Unit D 10 1880 660 810 970 1120 180 330 1470 1620 Unit I 11 1050 80 230 810 960 380 660 0 0
Unit D 11 1873 840 940 0 0 0 150 1721 1873 Unit I 12 1036 170 320 710 860 290 440 590 740
Unit D 12 1864 0 0 0 0 0 0 0 0 Unit I 13 1023 260 410 600 750 190 340 670 820
Unit D 13 1856 0 150 1708 1856 835 935 0 0 Unit I 14 1010 350 650 0 0 100 250 750 900
Unit D 14 1849 150 300 1450 1600 670 820 940 1090 Unit I 15 995 440 540 0 0 0 150 845 995
Unit D 15 1839 310 460 1270 1420 500 650 1100 1250 Unit J 1 980 0 0 0 0 0 0 0 0
Unit J 2 965 0 150 815 965 430 530 0 0
Unit J 3 952 80 230 720 870 350 600 0 0
R24000
Unit J 4 937 150 300 630 780 250 400 520 670
Unit J 5 924 230 380 530 680 170 320 590 740
Unit J 6 910 310 590 0 0 80 230 660 810
Unit J 7 895 390 490 0 0 0 150 745 895
Unit J 8 880 0 0 0 0 0 0 0 0
Unit J 9 870 0 150 720 870 380 480 0 0
Unit J 10 855 60 210 705 855 300 540 0 0
Unit J 11 842 130 280 550 700 160 310 450 600
Unit J 12 827 200 350 460 610 150 300 510 660
Unit J 13 816 270 530 0 0 70 220 570 720
Unit J 14 802 340 440 0 0 0 150 652 802
R9500 Unit J 15 788 0 0 0 0 0 0 0 0
Unit J 16 775 0 0 0 0 0 0 0 0

ISSUED FOR REVIEW


Project Drawing Number Revision

TAS-HWW-ARD-AIS-DRG-AUD-AEN-A3801 01.2
23/12/2022 10:49:20 AM

GENERAL NOTES Consultant Drawn By Designed By


1. THESE DRAWINGS FORM A COMPONENT OF THE OVERALL DESIGN
This drawing has been prepared by, or compiled from
information provided by, persons other than PTV. To the
maximum extent permissible by law, PTV takes no responsibility
ARCHITECTURAL J.PETITE E.SHAW
SOLUTION FOR THE ISS CIVIL - DESIGN PACKAGE TAS-D-CRD-2339-0485.
THEY DO NOT FORM A SEPARATE LANDSCAPE ARCHITECTURE DESIGN
for, and makes no representations in relation to, the
completeness, accuracy or quality of any information contained ARDEN Checked By Ind. Review
PACKAGE.
in this drawing. Each user of this drawing releases PTV from all
and any loss, damage, cost, expense or liability in relation to the ARDEN PRECINCT File Name C.GUTHRIE
2. THE DESIGN SCOPE FOR THIS PACKAGE DOES NOT DIRECTLY INTERFACE use of, or any reliance on, this drawing or the information
contained in it.
LANDSCAPE ARCHITECTURE Approved Approval Date
WITH ANY DESIGN PACKAGES OTHER THAN THE ISS CIVIL - DESIGN Franchisee / Lessee FENCE DETAILS - SHEET 02 Sheet No. SHEET 02 OF 02 APPROVER
PACKAGE TAS-D-CRD-2339-0485 (ALSO CONTAINING CIVIL - STORMWATER 01.2 14/10/2022 ISSUED FOR REVIEW ES CG
All written dimensions take precedence over scaled dimensions.
DRAINAGE DESIGN PACKAGE AND CIVIL - COMBINED UTILITIES DESIGN Up Location Down Location Datum Drawing Number Revision
PACKAGE) AND ARCHITECTURAL DESIGN PACKAGE TAS-A-ARC-1022-0441.
01.1 19/05/2022 ISSUED FOR REVIEW ES CG This drawing is provided only for the information of the person
or organisation to whom PTV provides it. It may not be provided East. East. In Serv
3. LEVELS TO AHD. MMRA HEIGHT DATUM = AHD + 100M. Revised By In Serv Rev. Date Description Designed Checked Ind. Rev. Approv. to, or used by, any other person without PTV's prior written North. North. Scale Sheet Size
consent.
ID# ID# As indicated A1