G.B.NAGAR, KALAVAI – 632 506. RANIPET DISTRICT MODEL EXAMINATION Set B Department : CIVIL Year/Semester : IV/VII Subject Code : CE8703 Date of Exam : 30.11.2022 Subject Title : STRUCTURAL DESIGN & Max. Marks : 100 DRAWING PART-A 1. a) Design a Cantilever Retaining wall at the height of earth embankment 20 is 5m and angle of internal friction φ=300,unit weight of soil is γ=18 KN/m3.Take co-efficient of friction factor of soil and concrete=0.6,then SBC=200 KN/m2.Using M20 and Fe415 grades. (OR) b) Design a Stem based on Counterfort retaining wall and the height of 20 earth embankment is 6m and SBC of soil is 180 KN/m 2 and then angle of internal friction φ=300.Take yield weight of soil is 18 KN/m3. Using M20and fe415 grades and assume spacing of counterfort is 3m. 2. a) An Interior panel of a flat slab floor is 6m x 6m along column centre 20 lines. Live load on floor is 3kN/m2.Supporting column diameter is 500 mm. Choosing the thickness of the slab (from stiffness criteria) and appropriate dimensions for column head and drops, calculate the design moments and shear forces. Use direct design method (OR) b) Design an Interior panel of a flat slab for a live load of 5kN/m 2 and a 20 column grid of 6mx6m. Columns are of 600mm diameter. Drops shall be provided. Show the reinforcement details in the flat slab. Use M20 concrete and Fe415 steel.Adopt limit state method of design. 3. a) A Square water tank 4mx4mx3m in height is supported on ground and 20 open at top. Assuming the base of the wall as hinged, design the thickness of the wall and reinforcement for the wall, for moment in vertical direction only. (OR) b) Design the underground water tank 4m x 6m x 2.2m with a freeboard 20 of 0.2m. The weight of subsoil is 16kN/m3. Angle of internal friction of soil is 34o. The subsoil is saturated at ground level. Safe bearing capacity of soil is 165kN/m2. Use M30 concrete and Fe415 steel. 4. a) Determine the design load on the Purlin of the industrial building near 20 Vishakhapatnam give clause of building general the life of 50 years. Terrain category II, max dimension 40m, width of building 15m, height of the elevation level-8m, topography-θ less than 3 0, permeability medium, span of truss-15m, pitch-1/5, sheeting-AC sheet, spacing of truss 4m, spacing of purlin 1.35m. (OR) b) Design a Steel Roof Truss to suit the following data: 20 Span of truss-15m, type-fan type, roof cover-GC, materials-rolled steel angles, spacing of the roof truss-4.5m, wind pressure=1.0kN/m2.draw the elevation of roof truss and details of joints. 5. a) Design a Welded Plate Girder of 30m span to support a Uniformly 20 Distributed Live load of 80kN/m over the span. Assume required data. (OR) b) Design a Gantry Girder of 25m Span. Assume required data. 20