You are on page 1of 2

Continuous Assessment Test II March 2018 Reg. No.

Programme : B.E. Date : 02/03/2018


Branch : Civil Engineering Time : 09.20am to 12.20pm
Semester : 06 Duration : 3Hrs
Subject code : CE 6603 Maximum : 100 Marks
Subject Name : Design of Steel Structures

PART A (10 x 2 = 20 Marks)


1 Why do compression flanges require lateral support?
2 Define web splices.
3 What is meant by slender section?
4 What are the classifications in stiffeners?
5 What are the different types of stiffeners provided in a plate girder?
6 What are the types of roof trusses?
7 What are the types of load combinations for the analysis of roof truss.
8 Draw neat sketch of various types of roof trusses.
9 What are the various forces acting on a gantry girder?
10 What is the equation to calculate the design wing pressure?

PART B (5 x 13 = 65 Marks)
11 a) Design a simply supported beam of span 5m to carry a factored uniformly
distributed load of 47KN/m
(13)
(or)
b) Design a load carrying stiffener to carry a load of 600KN for the section
ISMB 450.
(13)
12 a) Design a laterally restrained simply supported beam to carry a uniformly
distributed load of 44KN/m. The effective span of the beam is 8m. A bearing
length of 75mm is provided at the supports.
(13)
(or)
b) Design rolled steel I section for a simply supported beam with a clear span of
6m.It carries a UDL of 50KN/m exclusive of self weight of the girder. The
(13)
beam is laterally unsupported.

13 a) A simply supported beam of span 3.25 m consists of rolled steel section ISLB
325 @ 422.8 N/m. Determine the design bending strength of the beam, if the
(13)
beam is laterally unsupported.
(or)
b) Desgin the purlin for the following specifications. Span of truss = 12m,
Pitch = one fifth of span, Spacing of truss = 5m, Spacing of Purlins = 1.5m,
load from roofing materials = 200N/m2, wind load = 1200N/m2. Use angle
section. (13)
1
14 a) Design a purlin for a roof truss having the following data:
Span of the truss = 6m, Spacing of the truss = 3m c/c
Inclination of the the roof = 30, Spacing of purlin = 2m c/c
Wind pressure =1.5 KN/m2, Roof coverage = A.C sheeting
weighing 200N/m2, Provide a channel section purlin. (13)

(or)
b) List out various elements of the roof truss and give their design requirements. (13)

15 a) Design a channel section (shape purlin placed on a sloping roof truss) with a
dead loaof 0.15 kN/m2 (cladding and insulation). A live load of 2 kN/m 2 and
wind load of 0.5 kN/m2 (suction). The purlins are spaced 2 m c/c and span of
4 m, simply supported on a rafter at a slope of 20˚. (13)
(or)
b) Explain the step by step procedure of design of Gantry girders. Also explain
the loads you would consider in the design.
(13)
PART C (1 x 15 = 15 Marks)

16 a) Design an I section purlin for an industrial building situated in Mumbai to


support GI sheet. Assume the relevant data. (15)
(or)
b) A symmetric trusses of span 20m and height 5m are spaced at 4.5m c/c.
Design the channel section purlin to be placed at 1.4m distance to resist
following loads. Weight of sheeting including bolt = 171 N/m 2. Live load
=0.4 KN/m2. Wind load = 1.2KN/m2. (15)

Faculty Incharge HOD Dean Principal