1. A fully panelled double door with two intermediate rails is to be provided for an
opening of 1000 mm x 2100 mm in a 230 mm thick wall. Draw the elevation and cross
section of the door giving all the necessary dimensions so as to enable the carpenter to
complete the job without any difficulty. Position of the holdfast, hinges and bolts must
be clearly indicated. Door frame is 100 mm x 75 mm, size of styles and rails are 75
mm x 40 mm and thickness of panel boards is 25 mm.
Mark Allocation: Front view (40), Side view (30) and Top view (30)

2. A fully glazed single door with two intermediate rails and one intermediate style is to
be provided for an opening of 1000 mm x 2100 mm in a 230 mm thick wall. Draw the
elevation and cross section of the door giving all the necessary dimensions so as to
enable the carpenter to complete the job without any difficulty. Position of the
holdfast, hinges and bolts must be clearly indicated. Door frame is 100 mm x 75 mm,
size of styles and rails 75 mm x 40 mm and thickness of glass is 5 mm.
Mark Allocation: Front view (40), Side view (30) and Top view (30)

3. A fully panelled double window with two intermediate rails is to be provided for an
opening of 1000 mm x 1200 mm in a 230 mm thick wall. Draw the elevation and
cross section of the door giving all the necessary dimensions so as to enable the
carpenter to complete the job without any difficulty. Position of the holdfast, hinges
and bolts must be clearly indicated. Window frame is 100 mm x 75 mm, size of styles
and rails 75 mm x 40 mm and thickness of panel boards is 25 mm.
Mark Allocation: Front view (40), Side view (30) and Top view (30)

4. A fully glazed single door with two intermediate rails and one intermediate style is to
be provided for an opening of 1000 mm x 2100 mm in a 230 mm thick wall. Draw the
elevation and cross section of the door giving all the necessary dimensions so as to
enable the carpenter to complete the job without any difficulty. Position of the
holdfast, hinges and bolts must be clearly indicated. Window frame is 100 mm x 75
mm, size of styles and rails 75 mm x 40 mm and thickness of glass is 5 mm.
Mark Allocation: Front view (40), Side view (30) and Top view (30)

5. The sketch shows the line plan of house with R.C.C. roof. The dimensions noted
therein indicate the clear dimensions between the inside walls.
The specifications are given below:-
Foundation:Foundation shall be of P.C.C.1:4:8 mix, 1000 mm wide and 300 mm
thick laid at 1100 mm below G.L. for all main walls and veranda retaining wall. It
consists of two footings of size 700 mm X 400 mmand 500 mm X 400 mm in C.M.
1:6.
Basement:The basement will be in brick work in C.M. 1:5, 300 mm wide and 600
mm thick above G.L. A Damp Proof course in C. M. 1:3, 20 mm thick will be
provided for all walls. The basement is filled with earth for a height of 400 mm and
remaining with sand.
Super Structure:All main walls will be in brick work in C.M.1:5, 230 mm thick. The
inner partition walls in toilet will be 100 mm thick. The height of all the walls will be
3000 mm above floor level.
Steps: Provide steps of rise 150mm and tread 250 mm

Roofing: The roofing will be R.C.C. 1:2:4 mix, 120 mm thick flat slab. Veranda slab
will be of R.C.C. 1:2:4 mix, 100 thick at a height of 2600 mm from veranda floor
level. A weathering course in brick jelly lime concrete plastered with mortar 1:5:9
mix, 75 mm thick will be provided.
Lintels: R.C.C. lintel 120 mm thick over all the openings shall be provided. Suitable
sunshades for all external openings shall be provided.
Flooring: The flooring will be in C.C. 1:4:8, 120 mm thick plastered smooth with
C.M. 1:3, 20 mm thick for all the portions.
Doors: Panelled, D1-0.9mx2.1m, D2-1.0mx2.1m, D3-0.8mx2.0m, D4-1.2mx2.1m
Window& Ventilator: Glazed, W1-1.8mx1.2m, W2-0.9mx1.2m,W3-0.7mx0.6m, V-
0.6mx0.6m. The sill level of the window is 900 mm above the floor level.
Parapet wall: Height-450 mm
Assume any other necessary dimensions suitably
Draw the plan of the building at window sill level (30), Section on “ABCD”(40)and
Front Elevation (30)
6. The sketch shows the line plan of house with R.C.C. roof. The dimensions noted
therein indicate the clear dimensions between the inside walls.
The specifications are given below:-
Foundation: Foundation shall be of P.C.C.1:4:8 mix, 1000 mm wide and 300 mm
thick laid at 1100 mm below G.L. for all main walls and veranda retaining wall. It
consists of two footings of size 700 mm X 400 mm and 500 mm X 400 mm in C.M.
1:6.
Basement: The basement will be in brick work in C.M. 1:5, 300 mm wide and 600
mm thick above G.L. A Damp Proof course in C. M. 1:3, 20 mm thick will be
provided for all walls.The basement is filled with earth for a height of 400 mm and
remaining with sand.
Super Structure: All main walls will be in brick work in C.M.1:5, 230 mm thick.
The inner partition walls in toilet will be 100 mm thick. The height of all the walls
will be 3000 mm above floor level.
Steps: Provide steps of rise 150mm and tread 250 mm
Flooring: The flooring will be in C.C. 1:4:8, 120 mm thick plastered smooth with
C.M. 1:3, 20 mm thick for all the portions.
Roofing: The roofing will be R.C.C. 1:2:4 mix, 120 mm thick flat slab. Veranda slab
will be of R.C.C. 1:2:4 mix, 100 mm thick at a height of 2600 mm from veranda floor
level. A weathering course in brick jelly lime concrete plastered with mortar 1:5:9
mix, 75 mm thick will be provided.
Lintels: R.C.C. lintel 120 mm thick over all the openings shall be provided. Suitable
sunshades for all external openings shall be provided.
Parapet wall: Height-450 mm
The sill level of the window is 900 mm above the floor level.
Assume any other necessary dimensions suitably
Draw the plan of the building at window sill level (30), Section on “AB” (40) and
Front Elevation (30).

7. The sketch shows the line plan of house with R.C.C. roof. The dimensions noted
therein indicate the clear dimensions between the inside walls.
The specifications are given below:-
Foundation: Foundation shall be of P.C.C.1:4:8 mix, 1000 mm wide and 300 mm
thick laid at 1100 mm below G.L. for all main walls and veranda retaining wall. It
consists of two footings of size 700 mm X 400 mm and 500 mm X 400 mm in C.M.
1:6.
Basement: The basement will be in brick work in C.M. 1:5, 300 mm wide and 600
mm thick above G.L. A Damp Proof course in C. M. 1:3, 20 mm thick will be
provided for all walls.The basement is filled with earth for a height of 400 mm and
remaining with sand.
Super Structure: All main walls will be in brick work in C.M.1:5, 230 mm thick.
The inner partition walls in toilet will be 100 mm thick. The height of all the walls
will be 3000 mm above floor level.
Flooring: The flooring will be in C.C. 1:4:8, 120 mm thick plastered smooth with
C.M. 1:3, 20 mm thick for all the portions.
Roofing: The roofing will be R.C.C. 1:2:4 mix, 120 mm thick flat slab. Veranda slab
will be of R.C.C. 1:2:4 mix, 100 mm thick at a height of 2600 mm from veranda floor
level. A weathering course in brick jelly lime concrete plastered with mortar 1:5:9
mix, 75 mm thick will be provided.
Lintels: R.C.C. lintel 120 mm thick over all the openings shall be provided. Suitable
sunshades for all external openings shall be provided.
Doors: Panelled, Main Door 1.2mx2.1m, Room Doors-1.0mx2.1m, Bath Room
Doors-0.8mx2.0m
Window & Ventilator: Glazed, Main Rooms-1.5mx1.2m, Kitchen-1.2mx0.9m,
Ventilators for Bath Room and Toilet-0.6mx0.6m.The sill level of the window is 900
mm above the floor level.
Steps: Provide steps of rise 150mm and tread 250 mm
Locate the doors and windows at appropriate places
Parapet wall: Height-450 mm
Assume any other necessary dimensions suitably
Draw the plan of the building at window sill level (30), Section on “AB” (40) and
Front Elevation (30)
8. The sketch shows the line plan of house with R.C.C. roof. The dimensions noted
therein indicate the clear dimensions between the inside walls.

The specifications are given below:-


Foundation: Foundation shall be of P.C.C.1:4:8 mix, 1000 mm wide and 300 mm
thick laid at 1100 mm below G.L. for all main walls and veranda retaining wall. It
consists of two footings of size 700 mm X 400 mm and 500 mm X 400 mm in C.M.
1:6.
Basement: The basement will be in brick work in C.M. 1:5, 300 mm wide and 600
mm thick above G.L. A Damp Proof course in C. M. 1:3, 20 mm thick will be
provided for all walls.The basement is filled with earth for a height of 400 mm and
remaining with sand.
Super Structure: All main walls will be in brick work in C.M.1:5, 230 mm thick.
The inner partition walls in toilet will be 100 mm thick. The height of all the walls
will be 3000 mm above floor level.
Flooring: The flooring will be in C.C. 1:4:8, 120 mm thick plastered smooth with
C.M. 1:3, 20 mm thick for all the portions.
Roofing: The roofing will be R.C.C. 1:2:4 mix, 120 mm thick flat slab. Veranda slab
will be of R.C.C. 1:2:4 mix, 100 mm thick at a height of 2600 mm from veranda floor
level. A weathering course in brick jelly lime concrete plastered with mortar 1:5:9
mix, 75 mm thick will be provided.
Lintels: R.C.C. lintel 120 mm thick over all the openings shall be provided. Suitable
sunshades for all external openings shall be provided.
Doors: Panelled, Main Door 1.2mx2.1m, Room Doors-1.0mx2.1m, Bath Room
Doors-0.8mx2.0m
Window & Ventilator: Glazed, Main Rooms-1.5mx1.2m, Kitchen-1.2mx0.9m,
Ventilator for Bath Room and Toilet-0.6mx0.6m. The sill level of the window is 900
mm above the floor level.
Staircase: Thickness of the waist slab is 110 mm and width is 1000 mm
Steps: Provide steps of rise 150mm and tread 250 mm
Locate the doors and windows at appropriate places
Parapet wall: Height-450 mm
Assume any other necessary dimensions suitably
Draw the plan of the building at window sill level (30), Section on “AB” (40) and
Front Elevation (30).

9. The sketch shows the line plan of house with R.C.C. roof. The dimensions noted
therein indicate the clear dimensions between the inside walls.

The specifications are given below:-


Foundation: Foundation shall be of P.C.C.1:4:8 mix, 1000 mm wide and 300 mm
thick laid at 1100 mm below G.L. for all main walls and veranda retaining wall. It
consists of two footings of size 700 mm X 400 mm and 500 mm X 400 mm in C.M.
1:6.
Basement: The basement will be in brick work in C.M. 1:5, 300 mm wide and 600
mm thick above G.L. A Damp Proof course in C. M. 1:3, 20 mm thick will be
provided for all walls.The basement is filled with earth for a height of 400 mm and
remaining with sand.
Super Structure: All main walls will be in brick work in C.M.1:5, 230 mm thick.
The inner partition walls in toilet will be 100 mm thick. The height of all the walls
will be 3000 mm above floor level.
Flooring: The flooring will be in C.C. 1:4:8, 120 mm thick plastered smooth with
C.M. 1:3, 20 mm thick for all the portions.
Roofing: The roofing will be R.C.C. 1:2:4 mix, 120 mm thick flat slab. Veranda slab
will be of R.C.C. 1:2:4 mix, 100 mm thick at a height of 2600 mm from veranda floor
level. A weathering course in brick jelly lime concrete plastered with mortar 1:5:9
mix, 75 mm thick will be provided.
Lintels: R.C.C. lintel 120 mm thick over all the openings shall be provided. Suitable
sunshades for all external openings shall be provided.
Doors: Panelled, Main Door 1.2mx2.1m, Room Doors-1.0mx2.1m, Bath Room
Doors-0.8mx2.0m
Window & Ventilator: Partially Glazed, Main Rooms-1.5mx1.2m, Kitchen-
1.2mx0.9m, W3-0.7mx0.6m, V-0.6mx0.6m. The sill level of the window is
900 mm above the floor level.
Staircase: Thickness of the waist slab is 110 mm and width is 1000 mm
Steps: Provide steps of rise 150mm and tread 250 mm
Locate the doors and windows at appropriate places
Parapet wall: Height-450 mm
Assume any other necessary dimensions suitably
Draw the plan of the building at window sill level (30), Section on “AB” (40) and
Front Elevation (30)

10. The sketch shows the line plan of house with pitched woodenroof. The dimensions
noted therein indicate the clear dimensions between the inside walls.

The specifications are given below:-


Foundation: Foundation shall be of P.C.C.1:4:8 mix, 1000 mm wide and 300 mm
thick laid at 1100 mm below G.L. for all main walls and veranda retaining wall. It
consists of two footings of size 700 mm X 400 mm and 500 mm X 400 mm in C.M.
1:6.
Basement: The basement will be in brick work in C.M. 1:5, 300 mm wide and 600
mm thick above G.L. A Damp Proof course in C. M. 1:3, 20 thick will be provided for
all walls.The basement is filled with earth for a height of 400 mm and remaining with
sand.
Super Structure: All main walls will be in brick work in C.M.1:5, 230 mm thick.
The height of all the walls will be 3000 mm above floor level.
Flooring: The flooring will be in C.C. 1:4:8, 120 mm thick plastered smooth with
C.M. 1:3, 20 mm thick for all the portions.
Roofing:The pitch of the roof shall be ¼ span. The roofing willbe of mangalore tiles
over flat tiles set in lime mortar over teak wood reepers 50 mm x 120 mm placed @
150 mm c/c over teak wood rafters 50 mm x 120 mm placed @ 600 mm c/c. The
eaves projection will be 450 mm and eaves board of size 40 mm x 300 mm.
King post truss will be provided to support @ 3000 mm c/c. Sections of different
members for the king post truss may suitable be assumed.
Lintels: R.C.C. lintel 120 thick over all the openings shall be provided. Suitable
sunshades for all external openings shall be provided.
Doors: Panelled, Main Door 1.2mx2.1m, Room Door-1.0mx2.1m,
Window & Ventilator: Glazed, 1.8mx1.2m. The sill level of the window is 900 mm
above the floor level.
Steps: Provide steps of rise 150mm and tread 250 mm
Assume any other necessary dimensions suitably
Draw the plan of the building at window sill level (30), Section on “ABCD” (40) and
Front Elevation. (30)

11. The sketch shows the line plan of house with lean to roof. The dimensions noted
therein indicate the clear dimensions between the inside walls.

The specifications are given below:-


Foundation: Foundation shall be of P.C.C.1:4:8 mix, 1000 mm wide and 300 mm
thick laid at 1100 mm below G.L. for all main walls and veranda retaining wall. It
consists of two footings of size 700 mm X 400 mm and 500 mm X 400 mm in C.M.
1:6.
Basement: The basement will be in brick work in C.M. 1:5, 300 mm wide and 600 m
thick above G.L. A Damp Proof course in C. M. 1:3, 20 mm thick will be provided for
all walls.The basement is filled with earth for a height of 400 mm and remaining with
sand.
Super Structure: All main walls will be in brick work in C.M.1:5, 230 mm thick.
The inner partition walls in toilet will be 100 mm thick. The height of all the walls
will be 3600 mm above floor level. The height of the rear wall is 2100 mm for placing
inclined roof.
Flooring: The flooring will be in C.C. 1:4:8, 120 mm thick plastered smooth with
C.M. 1:3, 20 mm thick for all the portions.
Roofing: Office rooms will be flat roofing. The front and back veranda along with
bath & W.C. and store will be having inclined ‘lean to roof’. For the office rooms
R.C.C. slab of 120 mm thickness will be provided. A weathering course in brick jelly
lime concrete plastered with mortar 1:5:9 mix, 75 mm thick will be provided. The
roofing for loan to roof will be flat tiles which will be supported on 50 mm x 100 mm
teak wood reepers @ 300 mm c/c. The reepers will be supported on teak wood
common rafters 75 mm x 120 mm placed @ 750 mm c/c. The common rafter will be
supported over wall purlins of 75 mm x 100 mm section at the upper end and at lower
end on wall plate of section 150 mm x 120 mm. The wall purlin will be supported on
carbel stones of 150 mm x 250 mm x 400 mm size. 100 mm thick cement mortar
coping will be provided at upper end of the roofing for fixing the flat tiles with the
wall. Eaves projection will be 50 mm x 300 mm. G.I gutter pipe will be provided for
proper disposal of rain water.
Lintels: R.C.C. lintel 120 thick over all the openings shall be provided. Suitable
sunshades for all external openings shall be provided.
Doors: Panelled, Main Door 1.2mx2.1m, Room Door-1.0mx2.1m,
Window & Ventilator: Partially Glazed, Main Rooms-1.5mx1.2m, Kitchen-
1.2mx0.9m, W3-0.7mx0.6m, V-0.6mx0.6m. The sill level of the window is
900 mm above the floor level.
Steps: Provide steps of rise 150mm and tread 250 mm
Parapet wall: Height-450 mm
Assume any other necessary dimensions suitably
Draw the plan of the building at window sill level (30), Section on “AB” (40) and
Front Elevation (30).

12. The sketch shows the line plan of a work shop building with steel roof truss. The
dimensions noted therein indicate the clear dimensions between the inside walls.
Foundation: The foundation for all main walls will be in cement concrete1:5:10mix,
900 mm x 200 mm thick, laid at 600 mm below ground level. The masonry footing
will be in brick work in cement mortar 1:5 with 500 mm wide and 400 mm thick for
all walls
Basement: The basement will be in brickwork in cement mortar1:5,400 mm x 450
mm above ground level for all walls and is filled with earth, 300 mm thick.
Superstructure: All the pillars are 300 mm x300 mm and 4000 mm high at 3000 mm
C/C will be in brick work in cement mortar 1:5, for 4000 mm high. All the walls and
the pillars including the basement will be plastered smooth with cement mortar 1:4
externally and 1:5 internally for 12.5 mm thick.
Roofing: The roofing will be of asbestos cement sheet laid on steel truss as designed.
The trusses will be spaced at 3000 mm centre to centre. They are 5 bays. Eaves
projections will be 600 mm beyond the outer face of walls.
Doors, windows etc.:
RS -Rolling shutter : 3000 mm x 2400 mm
D1 -Steel door : 1000 mm x 2000 mm
D2 - Steel door : 800 mm x 2000 mm
W1 -Fixed glazed peeping window: 1500 mm x 1200 mm
W2 -Glazed window : 1000 mm x 1200 mm
The sill level of the window is 900 mm above the floor level.
V -Glazed ventilator: 1000 mm x 500 mm

Lintel: All external wall openings will be provided with R.C.C 1:1:5:3 mix, lintel
cum sunshade, 150 mm thick and 600 mm wide. All internal wall openings will be
provided with 150 mm thick R.C.C. 1:1:5:3: mix lintels.
Flooring: The flooring will be in cement 1:3:6 mix, 130 mm thick, and the top
plastered smooth with cement mortar 1:3, 20 mm thick.
Steps: Steps will be in brick work in cement mortar 1:5 mix, laid on 800 mm x 3700
mm, 150 mm thick cement concrete 1:5:10 mix footing. Rise=150 mm. Tread=300
mm. Ramp in cement concrete 1:4:8,3000 mm x 2000 mm will be provided.
Draw the plan of the building at window sill level (30), Section on “AB” (40) and
Front Elevation (30).

13. The sketch shows the line plan of a work shop building with steel roof truss. The
dimensions noted therein indicate the clear dimensions between the inside walls.
Foundation: The foundation for all main walls will be in cement concrete1:5:10mix,
900 mm x 200 mm thick, laid at 600 mm below ground level. The masonry footing
will be in brick work in cement mortar 1:5with 500 mm wide and 400 mm thick for
all walls.
Doors, windows etc.:
RS -Rolling shutter : 3000 mm x 2400 mm
D1 -Steel door : 1000 mm x 2000 mm
D2 - Steel door : 800 mm x 2000 mm
W1 -Fixed glazed peeping window: 1500 mm x 1200 mm
W2 -Glazed window : 1000 mm x1200 mm
The sill level of the window is 900 mm above the floor level.

Basement:The basement will be in brickwork in cement mortar1:5,400 mm x450 mm


above ground level for all walls and is filled with earth, 300 thick.
Superstructure:All the pillars, 300 mm x300 mm and 4000 mm high at3000 mm
C/C will be in brick work in cement mortar 1:5, for 4000 mm high. All the walls and
the pillars including the basement will be plastered smooth with cement mortar 1:4
externally and 1:5 internally for 12.5 mm thick.
Roofing:The roofing will be of asbestos cement sheet laid on steel truss as designed.
The trusses will be spaced at 3000 mmcentre to centre. They are 5 bays. Eaves
projections will be 600 mm beyond the outer face of walls.
Lintel:All external wall openings will be provided with R.C.C 1:1:5:3 mix,
lintelcumsunshade, 150 mm thick and 600 mm wide. All internal wall openings will
be provided with 150 mm thick R.C.C. 1:1:5:3: mix lintels.
Flooring:The flooring will be in cement 1:3:6 mix, 130 mm thick, and the top
plastered smooth with cement mortar 1:3, 20 mm thick.
Steps: Steps will be in brick work in cement mortar 1:5 mix, laid on 800 mm x3700
mm, 150 mm thick cement concrete 1:5:10 mix footing. Rise=150 mm. Tread=300
mm. Ramp in cement concrete 1:4:8,3000 mm x2000 mm will be provided.
Draw the plan of the building at window sill level (30), Section on “AB” (40) and
Front Elevation (30).

14. The sketch shows the line plan of a R.C.C. framed commercial complex. The
dimensions noted therein indicate the clear dimensions between the inside walls.
Foundation: Depth below G.L. is 800 mm. Width of footing is 600 mm. P.C.C.
concrete footing 1:4:8, 100 mm thick. Footing is of stone masonry 600 mm width,
700 mm height.
Basement: Height of basement is 450 mm. basement is of R.R. masonry in C.M. 1:6,
450 mm width. Floor finish is 20 mm thick. DPC is 20 mm thick. The columns are
connected by a plinth beam of size 300 mm x 500 mm.
Super Structure: Size of the columns are 250 mm x 500 mm. The filling between the
column is by brick wall of 230 mm thick in C.M. 1:5. Main beams are 250 mm x 500
mm. and cross beams are of size 250 mmx 300 mm. Suitable lintel beams between
columnsto span the opening for doors and windows.
Roof: R,C.C. roof slab 1:2:4, 120 mm thick. Cantilever beam length 1500 mm, 120
mm thick. The ceiling height for ground floor and for first floor is same and is 3000
mm. Wall in brick work with C.M. 1:5, 230 mm thick rests on the cantilever beam at
ground floor level extending upto parapet.
Sunshade: Width of sunshade is 600 mm. The bottom of the sunshade is 2100 mm
above the floor level.
Parapet: Brick work in C.M. 1:6, 230 mm thick and 700 mm above the roof slab.
Doors, Window and Ventilator:
Door D- 1200 mm x 2100 mm Panelled
Door D1 - 1000 x 21000 mm Panelled
Door D2 – 800 mm x 2100 mm Panelled
Rolling Shutter RS-3000 mm x 2100 mm
Window W-1500 mm x 1400 mm Glazed
The sill level of the window is 900 mm above the floor level.
Ventilator V-1000 mm x 600 mm Glazed
Assume any other required data suitably.
Draw the plan of the building at window sill level (30), Section on “AB” (40) and
Front Elevation (30).

15. The sketch shows the line plan of a R.C.C. framed commercial complex. The
dimensions noted therein indicate the clear dimensions between the inside walls.
Foundation: Depth below G.L. is 800 mm. Width of footing is 600 mm. P.C.C.
concrete footing 1:4:8, 100 mm thick. Footing is of stone masonry 600 mm width,
700 mm height.

Basement: Height of basement is 450 mm. basement is of R.R. masonry in C.M. 1:6,
450 mm width. Floor finish is 20 mm thick. DPC is 20 mm thick. The columns are
connected by a plinth beam of size 300 mm x 500 mm.
Super Structure: Size of the columns are 250 mm x 500 mm. The filling between the
column is by brick wall of 230 mm thick in C.M. 1:5. Main beams are 250 mm x 500
mm. and cross beams are of size 250 mmx 300 mm. Suitable lintel beams between
columns to span the opening for doors and windows.
Roof: R,C.C. roof slab 1:2:4, 120 mm thick. Cantilever beam length 1500 mm, 120
mm thick. The ceiling height for ground floor and for first floor is same and is 3000
mm. Wall in brick work with C.M. 1:5, 230 mm thick rests on the cantilever beam at
ground floor level extending upto parapet.
Sunshade: Width of sunshade is 600 mm. The bottom of the sunshade is 2100 mm
above the floor level.
Parapet: Brick work in C.M. 1:6, 230 mm thick and 700 mm above the roof slab.
Doors, Window and Ventilator:
Door D - 1200 mm x 2100 mm Panelled
Door D1 - 1000 x 21000 mm Panelled
Door D2 – 800 mm x 2100 mm Panelled
Rolling Shutter RS-3000 mm x 2100 mm
Window W-1500 mm x 1400 mm Glazed
The sill level of the window is 900 mm above the floor level.
Ventilator V-1000 mm x 600 mm Glazed
Assume any other required data suitably.
Draw the plan of the building at window sill level (30), Section on “AB” (40) and
Front Elevation (30).

16. The sketch shows the line plan of office with R.C.C. roof. The dimensions noted
therein indicate the clear dimensions between the inside walls.
The specifications are given below:-
Foundation: Foundation shall be of C.C.1:4:8 mix, 1000 mm wide and 300 mm thick
laid at 1100 mm below G.L. for all main walls and veranda retaining wall. It consists
of two footings of size 700 mm X 400 mm and 500 mm X 400 mm in C.M. 1:6.
Basement: The basement will be in brick work in C.M. 1:5, 300 mm wide and 600
mm thick above G.L. A Damp Proof course in C. M. 1:3, 20 mm thick will be
provided for all walls.
Super Structure: All main walls will be in brick work in C.M. 1:5, 230 mm thick.
The inner partition walls in toilet will be 100 mm thick. The height of all the walls
will be 3000 mm above floor level.
Roofing: The roofing will be R.C.C. 1:2:4 mix, 120 mm thick flat slab. Veranda slab
will be of R.C.C. 1:2:4 mix, 100 mm thick at a height of 2600 mm from veranda floor
level. A weathering course in brick jelly lime concrete plastered with mortar 1:5:9
mix, 75 mm thick will be provided.
Lintels: R.C.C. lintel 120 mm thick over all the openings shall be provided. Suitable
sunshades for all external openings shall be provided.
Flooring: The flooring will be in C.C. 1:4:8, 120 mm thick plastered smooth with
C.M. 1:3, 20 mm thick for all the portions.
Steps: Provide steps of rise 150mm and tread 250 mm
Doors: Panelled, D1-1.2mx2.1m.
Window & Ventilator: Partially Glazed, W1-1.5mx1.2m, W2-1.2mx1.2,V-
0.6mx0.6m. The sill level of the window is 900 mm above the floor level.
Steps: Provide steps of rise 150mm and tread 250 mm
Parapet wall: Height-450 mm
Assume any other necessary dimensions suitably
Draw the plan of the building at window sill level (30), Section on “ABCD” (40) and
Front Elevation (30).

17. The sketch shows the line plan of office with R.C.C. roof. The dimensions noted
therein indicate the clear dimensions between the inside walls.
The specifications are given below:-
Foundation: Foundation shall be of C.C.1:4:8 mix, 1000 mm wide and 300 mm thick
laid at 1100 mm below G.L. for all main walls and veranda retaining wall. It consists
of two footings of size 700 mm X 400 mm and 500 mm X 400 mm in C.M. 1:6.
Basement: The basement will be in brick work in C.M. 1:5, 300 mm wide and 600
mm thick above G.L. A Damp Proof course in C. M. 1:3, 20 mm thick will be
provided for all walls.
Super Structure: All main walls will be in brick work in C.M.1:5, 230 mm thick.
The inner partition walls in toilet will be 100 mm thick. The height of all the walls
will be 3000 mm above floor level.
Roofing: The roofing will be R.C.C. 1:2:4 mix, 120 mm thick flat slab. Veranda slab will
be of R.C.C. 1:2:4 mix, 100 mm thick at a height of 2600 mm from veranda floor level. A
weathering course in brick jelly lime concrete plastered with mortar 1:5:9 mix, 75 mm
thick will be provided.
Lintels: R.C.C. lintel 120 mm thick over all the openings shall be provided. Suitable

sunshades for all external openings shall be provided.


Flooring: The flooring will be in C.C. 1:4:8, 120 mm thick plastered smooth with
C.M. 1:3, 20 mm thick for all the portions.
Steps: Provide steps of rise 150mm and tread 250 mm
Doors: Panelled, Main Door 1.2mx2.1m, Room Door-1.0mx2.1m,
Window & Ventilator: Partially Glazed, Main Rooms-1.5mx1.2m. The sill level of
the window is 900 mm above the floor level.
Steps: Provide steps of rise 150mm and tread 250 mm
Parapet wall: Height-450 mm
Assume any other necessary dimensions suitably
Draw the floor plan at sill level of the building (30),Section on “ABCDEF” (40) and
Front Elevation (30).

18. a. Plan a residential building having a portico, a living room, two bed rooms, a
kitchen and three bath and toilet rooms. The total area of the building should not
2
exceed 100 m .
The building should be of load bearing wall with flat roof. (30)
b. Draw the floor plan at sill level and sectional elevation showing all details of the
building by considering the roof height is 3000 mm from floor level. Provide
sufficient number of doors and windows with suitable dimensions. (70)

19. a. Plan a residential building having a portico, a living room, two bed rooms, a
kitchen and three bath and toilet rooms. The total area of the building should not
2
exceed 100 m . The building should be of load bearing wall with pitched roof. (30)
b. Draw the floor plan at sill level and sectional elevation showing all details of the
building by considering the roof height is 3000 mm from floor level. Provide
sufficient number of doors and windows with suitable dimensions. (70)

20. a. Plan an industrial building consists of work space (10000 mm x 15000 mm),
office room (4000 mm x 4000 mm), dining (4000 mm x 4000 mm), wash room
(3000 mm x1800mm) and bath and toilets (1200 mm x 2600mm) separately for men
and women workers with steel roof. (30)
b. Draw the floor plan at sill level and sectional elevation showing all details of
the building by considering the roof height as 4000 mm, rise of the truss as 1500
mm and plinth levelas 450 mm. (70)