You are on page 1of 3

Diploma Board Examination – June 2021

Course: Diploma in Civil Engineering.

Subject : Civil Engineering Drawing – I. QP Code: 618

Time: 3 Hours Date: Sub Code: 31034 Max. Marks: 75

(Sketch ‘C’ to accompany)

[N.B: (1) Answer all questions under PART – A and PART – B in the drawing sheet
supplied.
(2) The sketches under PART – A should be drawn using pencil and drawing
instruments, not necessarily to scale.
(3) Any data, not given may be assumed suitably and should be indicated in the
drawing.]
PART – A
(15 marks)

I Answer the following: 2x3=6


1. Give the symbols for (i) Sand (ii) Glass (iii) Water closet.
2. State the minimum size requirement for any four types of rooms.

II Draw a laminated flush door of size 1000 × 2000 mm with the 1 x 9 = 9


following particulars.
Head and frame : 120 × 80 mm
Laminated cores : 20 mm thick
3 ply covers : 6 mm thick.

PART – B
(60 marks)

III The sketch shows the line plan of a two bed room house with R.C.C roof.
The dimensions noted there indicate the clear dimensions between the
inside walls. The specifications are given below.

1. Foundation: Foundation shall be of C.C 1:4:8 mix, 1000 wide and 300
thick laid at 1100 below G.L for all main walls and verandah retaining
wall. It consists of two footings of size 700 × 400 and 500 × 400 in
C.M 1:6.

2. Basement: The basement will be brick work in C.M 1:5, 300 mm wide
and 600 thick above G.L, A Damp proof course in C.M 1:3, 20 thick will
be provided for all walls.

3. Super Structures: All main walls will be in brick work in C.M 1:5,
200 mm thick. The inner partition walls in toilet will be 100mm thick.
The height of all the walls will be 3000 mm above floor level.
[Turn over….
-2-

4. Roofing: The roofing will be R.C.C 1:2:4 mix, 120mm thick flat slab,
verandah slab will be of R.C.C 1:2:4 mix, 100 thick at a height of 2600
mm from verandah floor level. A weathering course in brick jelly lime
concrete plastered with mortar 1:5:9 mix, 75mm thick will be provided.

5. Lintels: R.C.C lintel 120 thick over all the openings shall be provided.
Suitable sunshade for all external openings shall be provided.

6. Flooring: The flooring will be in C.C 1:4:8, 120mm thick plastered


smooth with C.M. 1:3, 20 mm thick for all the portions.

7. Doors, Windows & Ventilators:

D1 - Panelled door : 1100mm  2100mm


W1- Glazed window : 1200mm  1200mm
V - Ventilator glazed : 900mm  450mm

8. Steps: Provided steps of rise 150mm and tread 250mm.

Draw the following views to a suitable scale:


(i) Plan of the building (20 Marks)
(ii) Section on “AB” (25 Marks)
(iii) Front elevation (15 Marks)

-----
-3-