To: All Sperry Marine Offices and all authorized Service Stations

Subject: MK 2 Display flickering

Description: It was encountered with the temperature rise on some MK 2 main


boards the display starts flickering and above 40°C the main
board stops working due to Watchdog shutting down.

Required Action: This issue will be resolved by changing the MK 2 main board
Software.
The EEPROM with the contained Software will be available by
the 16th of April with Stock number
020669 in our European Distribution Center in the Netherlands.

Temporary solution to keep a vessel running is to take out the


displays from the socket. Secure the display inside the MK2 .
Make sure that you have done all settings before. Keep tracking
of that vessel for Software upgrading.

___________________________________
K. Neugebauer
Product Support
Sperry Marine Hamburg

Northrop Grumman Sperry Marine B.V.