Question 1 1 out of 1 points

Consider the following heat exchanger control instrumentation diagram. For the


diagram, the control objective is to maintain a desired cold stream outlet
temperature. Since the cold stream exiting the exchanger is fed to a reactor, it is
critical that the stream temperature never be substantially higher than the set
point value (or the world explodes). 

Is the PROCESS gain relating the manipulated flow rate to the measured
temperature positive or negative?

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 1/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

Selected Answers: B.
positive
Answers: A.
negative
B.
positive

Question 2 1 out of 1 points

Consider the following heat exchanger control instrumentation diagram. For the


diagram, the control objective is to maintain a desired cold stream outlet temperature.
Since the cold stream exiting the exchanger is fed to a reactor, it is critical that the
stream temperature never be substantially higher than the set point value (or the world
explodes). 

Is the PROCESS gain relating the manipulated flow rate to the measured
temperature positive or negative?

Selected Answers: A.
negative
Answers: A.
negative
B.
positive

Question 3 0.5 out of 1 points

A process furnace heats a process stream from near ambient conditions to a desired
temperature of 300 C. The process stream outlet temperature is regulated by
manipulating the flow rate of fuel gas to the furnace, as shown below.

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 2/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

Select all possible disturbances?

Selected Answers: B.
process fluid flowrate
D.
process fluid inlet temperature
Answers: A.
fuel gas upstream pressure
B.
process fluid flowrate
C.
fuel gas quality
D.
process fluid inlet temperature

Question 4 1 out of 1 points

Consider the following heat exchanger control instrumentation diagram. For the


diagram, the control objective is to maintain a desired cold stream outlet temperature.
Since the cold stream exiting the exchanger is fed to a reactor, it is critical that the
stream temperature never be substantially higher than the set point value (or the world
explodes). 

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 3/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

Should the valve be fail-open or fail-closed?

Selected Answers: A.
fail-open
Answers: A.
fail-open
B.
fail-closed

Question 5 1 out of 1 points

Consider the following heat exchanger control instrumentation diagram. For the


diagram, the control objective is to maintain a desired cold stream outlet temperature.
Since the cold stream exiting the exchanger is fed to a reactor, it is critical that the
stream temperature never be substantially higher than the set point value (or the world
explodes). 

Should the valve be fail-open or fail-closed?

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 4/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

Selected Answers: B.
fail-closed
Answers: A.
fail-open
B.
fail-closed

Question 6 1 out of 1 points

Click on the spot of the image where the controller is illustrated.

Selected Answer: 290, 167


Answers:
Student Response

Question 7 1 out of 1 points

One motivation for studying and implementing process dynamics and control is to
minimize safety issues.

Selected Answer: True


Answers: True
False

Question 8 1 out of 1 points

Consider the following heat exchanger control instrumentation diagram. For the


diagram, the control objective is to maintain a desired cold stream outlet temperature.
Since the cold stream exiting the exchanger is fed to a reactor, it is critical that the
stream temperature never be substantially higher than the set point value (or the world
explodes). 

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 5/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

Is the PROCESS gain relating the manipulated flow rate to the measured
temperature positive or negative?

Selected Answers: B.
negative
Answers: A.
positive
B.
negative

Question 9 1 out of 1 points

A process furnace heats a process stream from near ambient conditions to a desired
temperature of 300 C. The process stream outlet temperature is regulated by
manipulating the flow rate of fuel gas to the furnace, as shown below. NOTE: If the
process fluid outlet stream gets above a certain temperature, the universe implodes!

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 6/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

Based on whether the control valve is fail-open or fail closed, is the VALVE gain
positive or negative? NOTE: Remember our general definition of gain applied to the
valve.

Selected Answers: A.
positive
Answers: A.
positive
B.
negative

Question 10 1 out of 1 points

Click on the spot of the image where the sensor for the process control output is
illustrated.

Selected Answer: 233, 99


Answers:
Student Response

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 7/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

Question 11 1 out of 1 points

Gain has units of input units over output units.

Selected Answer: False


Answers: True
False

Question 12 2 out of 2 points

Examples of hard process control constraints are:

Selected Answers: max/min temperature


max/min flowrate
Answers: block diagram
controller
manipulated
measured
max/min temperature
max/min flowrate
batch/semi-batch
positive gain

Question 13 1 out of 1 points

A process furnace heats a process stream from near ambient conditions to a desired
temperature of 300 C. The process stream outlet temperature is regulated by
manipulating the flow rate of fuel gas to the furnace, as shown below.
https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 8/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

What is the manipulated input?

Selected Answer: C.
Fuel gas inlet flow rate

Answers: A.
Process fluid inlet temperature

B.
Process fluid outlet temperature

C.
Fuel gas inlet flow rate

D.
Fuel gas outlet flow rate

Question 14 6 out of 6 points

Match the process control term to their most appropriate meanings.

Question Selected Match

Feedback V.
use measurement of output to control manipulated input
control

Feedforward II.
control use measurement of disturbance input to control manipulated
input 

controlled VI.
variable variable which quantifies the performance or quality of the final
product

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 9/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

manipulated IV.
variable input variable that is adjusted dynamically to keep the controlled
variable at its setpoint

load variable I.
input variable that can cause the measured variable to deviate
from the setpoint

process gain III.


relationship between the process input and output

All Answer Choices

I.
input variable that can cause the measured variable to deviate from the setpoint

II.
use measurement of disturbance input to control manipulated input 

III.
relationship between the process input and output

IV.
input variable that is adjusted dynamically to keep the controlled variable at its
setpoint

V.
use measurement of output to control manipulated input

VI.
variable which quantifies the performance or quality of the final product

Question 15 1 out of 1 points

In practice, FB and FF control are ______________ to take into account process


disturbances, but also try to not interrupt the output. 

Selected Answer: B.
often combined

Answers: A.
rarely used

B.
often combined

C.
never used

D.
used individually 

Question 16 1 out of 1 points

Consider the following heat exchanger control instrumentation diagram. For the


diagram, the control objective is to maintain a desired cold stream outlet temperature.
Since the cold stream exiting the exchanger is fed to a reactor, it is critical that the
stream temperature never be substantially higher than the set point value (or the world
explodes). 

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 10/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

Should the valve be fail-open or fail-closed?

Selected Answers: B.
fail-open
Answers: A.
fail-closed
B.
fail-open

Question 17 0 out of 1 points

As a process gain increases (through manipulation of flow rates, etc.) the system's
sensitivity will decrease. 

Selected Answer: True


Answers: True
False

Question 18 1 out of 1 points

A process furnace heats a process stream from near ambient conditions to a desired
temperature of 300 C. The process stream outlet temperature is regulated by
manipulating the flow rate of fuel gas to the furnace, as shown below. NOTE: If the
process fluid outlet stream gets above a certain temperature, the universe implodes!

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 11/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

Should the control valve be fail-open or fail closed?

Selected Answers: B.
Fail-closed
Answers: A.
Fail-open
B.
Fail-closed

Question 19 4 out of 4 points

Match appropriately.

Question Selected Match

fail-open D.
valve will open completely upon signal loss

fail-closed C.
valve will close completely upon signal loss

analog signal A.
continuous (pneumatic) signals

digital signal B.
discrete (electronic) signals

All Answer Choices

A.
continuous (pneumatic) signals

B.
discrete (electronic) signals

C.
valve will close completely upon signal loss

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 12/13
9/19/21, 2:18 PM Review Test Submission: Bb Quiz 1 - Introduction to Controls &...

D.
valve will open completely upon signal loss

Question 20 1 out of 1 points

A process furnace heats a process stream from near ambient conditions to a desired
temperature of 300 C. The process stream outlet temperature is regulated by
manipulating the flow rate of fuel gas to the furnace, as shown below.

Is this a feed-forward or feed-back controller?

Selected Answers: A.
Feed-back
Answers: A.
Feed-back
B.
Feed-forward
Sunday, September 19, 2021 6:17:09 AM CDT


OK

https://ualearn.blackboard.com/webapps/assessment/review/review.jsp?attempt_id=_61736481_1&course_id=_209905_1&content_id=_6763247_1… 13/13